west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CHEN Xiaotian" 7 results
  • Application of percutaneous screwdriver rod-assisted closed reduction in treatment of valgus-impacted femoral neck fractures

    ObjectiveTo evaluate the feasibility and effectiveness of percutaneous screwdriver rod-assisted closed reduction in the treatment of valgus-impacted femoral neck fractures. MethodsBetween January 2021 and May 2022, 12 patients with the valgus-impacted femoral neck fractures were treated with percutaneous screwdriver rod-assisted closed reduction and femoral neck system (FNS) internal fixation. There were 6 males and 6 females with a median age of 52.5 years (range, 21-63 years). The fractures were caused by traffic accident in 2 cases, falling in 9 cases, and falling from height place in 1 case. All were unilateral closed femoral neck fractures, including 7 on the left side and 5 on the right side. The time from injury to operation was 1-11 days, with an average of 5.5 days. The fracture healing time and postoperative complications were recorded. The quality of fracture reduction was evaluated by Garden index. At last follow-up, Harris score was used to evaluate the hip joint function, also the shortening of femoral neck was measured. ResultsAll the operations were successfully completed. After operation, the incision fat liquefaction occurred in 1 case, which healed after enhanced dressing change, and the other patients’ incisions healed by first intention. All patients were followed up 6-18 months, with an average of 11.7 months. The X-ray film reexamination showed that the quality of fracture reduction was grade Ⅰ in 10 cases and grade Ⅱ in 2 cases according to the Garden index. All fractures reached bony union, and the healing time was 3-6 months, with an average of 4.8 months. At last follow-up, the femoral neck was shortened by 1-4 mm, with an average of 2.1 mm. No internal fixation failure or osteonecrosis of the femoral head occurred during follow-up. At last follow-up, the hip Harris score was 85-96, with an average of 92.4; 10 cases were rated as excellent and 2 were good. Conclusion The percutaneous screwdriver rod-assisted closed reduction can effectively reduce the valgus-impacted femoral neck fracture. It has the advantages of simple operation, effective, and less impact on blood supply.

    Release date: Export PDF Favorites Scan
  • Early effectiveness analysis of lateral hinge fracture during medial opening-wedge high tibial osteotomy

    ObjectiveTo compare the clinical and radiologic effectiveness in patients with versus without lateral hinge fracture during medial opening-wedge high tibial osteotomy (MOWHTO) to evaluate the effect of lateral hinge fracture on short-term effectiveness.MethodsThe clinical data of 84 patients (97 knees) with medial compartment osteoarthritis who treated with MOWHTO between September 2015 and July 2018 was retrospectively analyzed. There were 10 males (10 knees) and 74 females (87 knees). The age ranged from 45 to 65 years with an average of 57.7 years. Lateral hinge fracture was recognized by the intraoperative fluoroscopy or immediate postoperative X-ray film. Fractures were classified into types Ⅰ, Ⅱ, and Ⅲ according to the Takeuchi classification. The healing of osteotomy was observed by radiographs during follow-up; the femur tibia angle (FTA), medialproximal tibial angle (MPTA), and hip-knee-ankle angle (HKA) were also calculated. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score and knee society score (KSS).ResultsThe incision healed by first intention. All patients were followed up 15-48 months with an average of 24.8 months. No hinge fracture occurred in 78 knees (80.41%, group A), and lateral hinge fractures were observed in 19 knees (19.59%, group B) and were divided into the type Ⅰ (13 knees, 13.40%) and type Ⅲ (6 knees, 6.19%) groups. Type Ⅰ fractures were not additionally treated, type Ⅲ fractures were anatomic reduced fixed with additional lag screws. X-ray film and CT examination showed that all patients had bone healing at 3 months after operation without delayed healing or nonunion. During follow-up, there was no loosening or fracture of internal fixation plates and screws. HKA, FTA, and MPTA of patients in group A and group B (type Ⅰ and Ⅲ) were significantly improved at each time point after operation compared with preoperative values (P<0.05); there was no significant difference between groups at each time point before and after operation (P>0.05). After operation, the pain of knee joint was alleviated and the function of joint was improved. At last follow-up, KSS score and HSS score of groups A and B were significantly improved compared with those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05).ConclusionThe lateral hinge fracture may occur during MOWHTO. As long as the treatment and rehabilitation were guided according to the fracture classification of the hinge, the effectiveness can be similar to those without the hinge fracture.

    Release date:2020-07-27 07:36 Export PDF Favorites Scan
  • Surgical technique and effectiveness of titanium elastic nail assisted retrograde channel screw implantation in superior pubic branch

    Objective To investigate the surgical technique and effectiveness of titanium elastic nail (TEN) assisted retrograde channel screw implantation of superior pubic branch. Methods The clinical data of 31 patients with pelvic or acetabular fractures treated with retrograde channel screw implantation in superior pubic branch between January 2021 and April 2022 were retrospectively analyzed. Among them, 16 cases were implanted with assistance of TEN (study group) and 15 cases were implanted under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification of pelvic fracture, Judet-Letournal classification of acetabular fracture, and time from injury to operation between the two groups (P>0.05). The operation time, fluoroscopy times, and intraoperative blood loss of each superior pubic branch retrograde channel screw were recorded during operation. X-ray films and three-dimensional CT were reexamined after operation, the quality of fracture reduction was evaluated by Matta score standard, and the position of channel screw was evaluated by screw position classification standard. The fracture healing time was recorded during the follow-up, and the postoperative functional recovery was evaluated by Merle D’Aubigne Postel score system at last follow-up. Results Nineteen and 20 retrograde channel screws of superior pubic branch were implanted in the study group and the control group, respectively. The operation time, fluoroscopy times, and intraoperative blood loss of each screw in the study group were significantly less than those in the control group (P<0.05). According to the postoperative X-ray films and three-dimensional CT, none of the 19 screws in the study group penetrated out of the cortical bone or into the joint, and the excellent and good rate was 100% (19/19); in the control group, there were 4 screws of cortical bone penetration, and the excellent and good rate was 80% (16/20); the difference between the two groups was significant (P<0.05). Matta score standard was used to evaluate the quality of fracture reduction, there was no patient in the two groups with poor reduction results, and the difference was not significant between the two groups (P>0.05). The incisions of the two groups healed by first intention, and there was no complication such as incision infection, skin margin necrosis, and deep infection. All patients were followed up 8-22 months, with an average of 14.7 months. There was no significant difference in healing time between the two groups (P>0.05). At last follow-up, the difference in functional recovery evaluated by the Merle D’Aubigne Postel scoring system between the two groups was not significant (P>0.05). Conclusion TEN assisted implantation technique can significantly shorten the operation time of retrograde channel screw implantation of superior pubic branch, reduce the times of fluoroscopy, and have less intraoperative blood loss and accurate screw implantation, which provides a new safe and reliable method for minimally invasive treatment of pelvic and acetabular fractures.

    Release date: Export PDF Favorites Scan
  • Effectiveness of locking compress plate and extra cortical bone bridge fixation for treatment of atrophic humeral nonunions

    Objective To assess the effectiveness of locking compress plate and extra cortical bone bridge fixation for treating atrophic humeral nonunion. Methods Seventeen patients with atrophic humeral nonuninon were treated with locking compress plate and extra cortical bone bridge fixation between November 2006 and June 2015. Of 17 cases, 11 were male, 6 were female, aged 24-63 years (mean, 38.2 years). Fracture located at the left side in 9 cases and at the right side in 8 cases. The mechanism of injury was traffic accident in 13 cases, falling from height in 3 cases, and heavy pound injury in 1 case. The patients underwent surgery for 1 time in 7 cases, for 2 times in 5 cases, for 3 times in 4 cases, and for 4 times in 1 case. The time from fracture to hospitalization was 10-76 months (mean, 22.6 months). The shoulder function was evaluated by Neer score, and elbow function by Mayo score. Results All incisions healed by first intention. Two cases had transient radial nerve symptoms of numbness. All patients were followed up 27.3 months on average (range, 15-60 months). Radiographic examination showed signs of bone remodeling at 6-8 weeks after operation, and formation of extra cortical bone bridge. All of them achieved bone union within 10 to 41 weeks (mean, 17.6 weeks). At last follow-up, the average Neer score was 83.36 (range, 72-96); and the shoulder function was excellent in 10 cases, good in 5, and fair in 2 with an excellent and good rate of 88.24%. And the average Mayo score was 86.52 (range, 68-100); and the elbow function was excellent in 11 cases, good in 3, and fair in 3 with an excellent and good rate of 82.35%. Conclusion The bone bridging could effectively form by extra cortical grafting technique. Atrophic humeral nonunions can be successfully treated with locking compress plate and extra cortical bone bridge fixation.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • Application of three-dimensional printing technology for closed reduction and percutaneous cannulated screws fixation of displaced intraarticular calcaneus fractures

    Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Modified internal fixator combined with sacroiliac screws in treatment of Tile C1.3 pelvic fracture

    Objective To investigate the effectiveness of modified internal fixator (INFIX) to fix the anterior pelvic ring for Tile C1.3 pelvic fracture by comparing with the traditional INFIX. MethodsThe patients with Tile C1.3 pelvic fractures admitted between April 2018 and June 2021 were taken as the study objects. Of them, 55 cases were included in the study according to the selection criteria. During operation, the anterior pelvic ring was fixed with the modified INFIX in 30 cases (modified group) and with the traditional INFIX in 25 cases (control group). The posterior pelvic ring in 55 cases was fixed with sacroiliac screws. There was no significant difference between the two groups in gender, age, cause of injury, time from injury to operation, and combined injury (P>0.05). The operation time, intraoperative blood loss, and complications were recorded and compared between the two groups. The X-ray film was taken to evaluate the reduction of the anterior pelvic ring after operation, grade the reduction according to the Matta scoring standards, and observe the fracture healing and healing time. The function was evaluated according to Majeed scoring standards during follow-up. Results The operation time of the modified group was significantly longer than that of the control group (Z=–3.837, P<0.001), but there was no significant difference in the intraoperative blood loss between the two groups (t=–1.831, P=0.076). All patients were followed up 12-18 months (mean, 14 months). X-ray film reexamination showed that the excellent and good rate of Matta scoring for anterior pelvic ring reduction in the modified group was 88.00%, which was significantly better than that in the control group (63.33%) (χ2=4.373, P=0.037). All fractures healed, and the fracture healing time of the modified group and the control group was (12.04±3.59) and (14.83±4.83) weeks respectively, with a significant difference (t=2.401, P=0.020). At last follow-up, the excellent and good rates of Majeed scoring were 80.00% in the modified group and 76.67% in the control group, with no significant difference (χ2=0.089, P=0.766). In the modified group, 2 cases (8%) had complications, all of which were incision infection above pubic symphysis. In the control group, 9 cases (30%) had complications, including 5 cases of lateral femoral cutaneous nerve injury, 2 cases of femoral nerve paralysis, and 2 cases of delayed fracture healing. The incidence of complications was significantly lower in the modified group than in the control group (χ2=4.125, P=0.042). ConclusionCompared with the traditional INFIX, the modified INFIX to fix the anterior pelvic ring for Tile C1.3 pelvic fracture has fewer complications, better stability, shorter fracture healing time, and lower risk of nerve injury.

    Release date: Export PDF Favorites Scan
  • Experiences with the infra-acetabular screw placement technique in acetabular fracture surgery

    Objective To investigate the application experiences and effectiveness of the infra-acetabular screw (IAS) placement technique in acetabular fracture surgery. MethodsA clinical data of 34 patients with complex acetabular fractures with anterior and posterior columns separation, who were admitted between January 2019 and October 2023 and treated with IAS fixation, was retrospectively analyzed. There were 23 males and 11 females with an average age of 55.3 years (range, 18-78 years). The acetabular fractures caused by traffic accident in 20 cases, falling from height in 12 cases, crushing injury in 1 case, and bruising with a heavy object in 1 case. According to the Letournel-Judet classification, there were 7 cases of anterior column fracture, 8 cases of anterior wall/column plus posterior hemi-transverse fracture, 2 cases of T-shaped fracture, and 17 cases of both-column fracture. The time from injury to surgery was 4-21 days (mean, 8.6 days). The time of IAS placement and the intraoperative blood loss were recorded. After surgery, the X-ray film and CT scan were re-examined, and the modified Matta score was used to assess the quality of fracture reduction. The trajectory of IAS in the channel was analyzed based on CT scan, and the screw length was measured. During follow-up, the fracture healing was observed and the hip function was assessed according to the modified Merle d’Aubigné-Postel scoring system at last follow-up. Results The IAS was successfully implanted in all 34 patients. The length of IAS ranged from 70 to 100 mm (mean, 86.2 mm). The time of IAS placement ranged from 10 to 40 minutes (mean, 20.7 minutes). The intraoperative blood loss ranged from 520 to 820 mL (mean, 716.8 mL). All patients were followed up 8-62 months (mean, 21.8 months). After surgery, 4 patients developed lateral femoral cutaneous nerve injury, 2 developed popliteal vein thrombosis of the lower extremity, 3 developed incision infection, and no surgical complication such as arteriovenous injury or obturator nerve palsy occurred. At last follow-up, the hip function was rated as excellent in 14 cases, good in 13 cases, fair in 4 cases, and poor in 3 cases according to the Merle d’Aubigné-Postel scoring system, with an excellent and good rate of 79.41%. Imaging re-examined showed that the quality of fracture reduction was rated as excellent in 9 cases, good in 19 cases, and poor in 6 cases according to the modified Matta score, with an excellent and good rate of 82.35%; and 25 (73.53%) IAS trajectories were located in the channel. All fractures obtained bony union, and the healing time was 12-24 weeks (mean, 18 weeks). During follow-up, there was no loosening or fracture of the plate and screws. Conclusion IAS placement technique can effectively strengthen internal fixation and prevent fracture re-displacement, making it a useful adjunct for treating complex acetabular fractures with anterior and posterior columns separation.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content