Most of the existing near-infrared noninvasive blood glucose detection models focus on the relationship between near-infrared absorbance and blood glucose concentration, but do not consider the impact of human physiological state on blood glucose concentration. In order to improve the performance of prediction model, particle swarm optimization (PSO) algorithm was used to train the structure paramters of back propagation (BP) neural network. Moreover, systolic blood pressure, pulse rate, body temperature and 1 550 nm absorbance were introduced as input variables of blood glucose concentration prediction model, and BP neural network was used as prediction model. In order to solve the problem that traditional BP neural network is easy to fall into local optimization, a hybrid model based on PSO-BP was introduced in this paper. The results showed that the prediction effect of PSO-BP model was better than that of traditional BP neural network. The prediction root mean square error and correlation coefficient of ten-fold cross-validation were 0.95 mmol/L and 0.74, respectively. The Clarke error grid analysis results showed that the proportion of model prediction results falling into region A was 84.39%, and the proportion falling into region B was 15.61%, which met the clinical requirements. The model can quickly measure the blood glucose concentration of the subject, and has relatively high accuracy.
The use of non-invasive blood glucose detection techniques can help diabetic patients to alleviate the pain of intrusive detection, reduce the cost of detection, and achieve real-time monitoring and effective control of blood glucose. Given the existing limitations of the minimally invasive or invasive blood glucose detection methods, such as low detection accuracy, high cost and complex operation, and the laser source's wavelength and cost, this paper, based on the non-invasive blood glucose detector developed by the research group, designs a non-invasive blood glucose detection method. It is founded on dual-wavelength near-infrared light diffuse reflection by using the 1 550 nm near-infrared light as measuring light to collect blood glucose information and the 1 310 nm near-infrared light as reference light to remove the effects of water molecules in the blood. Fourteen volunteers were recruited for in vivo experiments using the instrument to verify the effectiveness of the method. The results indicated that 90.27% of the measured values of non-invasive blood glucose were distributed in the region A of Clarke error grid and 9.73% in the region B of Clarke error grid, all meeting clinical requirements. It is also confirmed that the proposed non-invasive blood glucose detection method realizes relatively ideal measurement accuracy and stability.