west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "CT" 530 results
  • Value of MRI and MDCT in Detecting Both Inferior Vena Cava Tumor Thrombus and Vena Cava Wall Invasion in Renal Cell Carcinoma: A Systematic Review

    Objective To evaluate the value of MRI and MDCT in detecting both inferior vena cava tumor thrombus and vena cava wall invasion in renal cell carcinoma. Methods Databases including PubMed, EMbase, The Cochrane Library, MEDLINE (Ovid), CBM, CNKI, VIP and WanFang Data were searched from January 2000 to February 2012. Relevant studies were screened on the basis of the inclusion and exclusion criteria, and then quality assessment and data extraction were conducted. Then heterogeneity test and meta-analysis were conducted using RevMan 5 and Meta-disc 1.4. Results A total of 6 trials involving 244 patients and 246 cases of renal cell carcinoma were included. The results of meta-analysis showed that, for the MRI group and the MDCT group, the sensitivity was 0.963 and 0.952, the specificity was 0.969 and 0.979, the value of +LR was 9.759 and 15.57, the value of −LR was 0.091 and 0.108, and the dOR was 198.71 and 251.54, respectively. There were no significant differences in pooled effect-size among groups (Pgt;0.05). The area under curve (AUC) of summary ROC curve analysis as well as Q index of the MDCT group were 0.981 8 and 0.940 7, respectively. Conclusion There is no significant difference in the value of MRI and MDCT in detecting inferior vena cava tumor thrombus induced by renal cell carcinoma. More original studies on vena cava wall invasion by tumor thrombus should be conducted in the future due to the limitation of current materials.

    Release date: Export PDF Favorites Scan
  • ROC Analysis on the Value of 3-D Reconstruction in Multi-Detector Spiral CT Urography for Upper Urinary Tract Diseases

    Objective To evaluate the value of 3-D reconstruction in multi-detector spiral CT urography (MDCTU) for diagnosing upper urinary tract diseases (UUTDs) by means of both diagnostic sensitivity and ROC curve. Methods A total of 41 patients with UUTD were collected. All of them took MDCTU as well as reconstructions including MPR, MIP and VR. Compared with golden standards, the diagnostic value of MDCTU, MPR, MIP and VR were evaluated using both diagnostic sensitivity and ROC curve. Results a) A total of 49 upper urinary tract lesions were detected in those 41 patients; b) For UUTD, the localization diagnostic sensitivities of MPR, MIP, and VR were 48/49 (98.0%), 27/49 (53.2%), and 19/49 (38.8%), respectively; while their qualitative diagnostic sensitivities were 47/49 (95.9%), 17/49 (34.7%), and 13/49 (26.5%), respectively; the differences between MPR and the others were significantly (Plt;0.05); c) For distinguishing benign from malignant lesions, the Az value (area under ROC curve) of MPR, MIP, and VR were 0.998, 0.736 and 0.669, respectively; the differences between MPR and the others were significant (Plt;0.05); and d) MPR was completely the same as MDCTU in both diagnostic sensitivity and Az value. Conclusion The common 3-D reconstructions in MDCTU were different in value. MPR is highest in the diagnostic efficiency, which is similar to MDCTU, and is regarded as the basis of diagnosis; while MIP and VR are more stereo and intuitive. So it shows that the comprehensive application of CTU 3-D reconstructions has important value for diagnosing UUTD and distinguishing benign from malignant.

    Release date: Export PDF Favorites Scan
  • COMPARISON OF FEMORAL CONDYLAR TWIST ANGLE IN THREE DIMENSIONAL RECONSTRUCTION DIGITAL MODELS OF KNEE JOINT BASED ON TWO DIMENSIONAL IMAGES OF MRI AND CT

    ObjectiveTo study the difference of femoral condylar twist angle (CTA) measurement in three dimensional (3-D) reconstruction digital models of human knee joint based on the two dimensional (2-D) images of MRI and CT so as to provide a reference for selecting the best method of CTA measurement in preoperative design for the femoral prosthesis rotational position. MethodsThe CTA of 10 human cadaveric knee joint was measured in 3-D digital models based on MRI (group A), in 3-D digital models based on CT (group B), in the cadaveric knee joint with cartilage (group C), and in the cadaveric knee joint without cartilage (group D), respectively. The statistical analysis of the differences was made among the measurements of the CTA. ResultsThe CTA values measured in 3-D digital models were (6.43±0.53)° in group A and (3.31±1.07)° in group B, showing significant difference (t=10.235, P=0.000). The CTA values measured in the cadaveric knee joint were (5.21±1.28)° in group C and (3.33±1.12)° in group D, showing significant difference (t=5.770, P=0.000). There was significant difference in the CTA values between group B and group C (t=5.779, P=0.000), but no significant difference was found between group A and group C (t=3.219, P=0.110). ConclusionThe CTA values measured in the 3-D digital models based on MRI are closer to the actual values measured in the knee joint with cartilage, and benefit for preoperative plan.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • Application of Three-dimensional CT Angiogram in Perioperative Evaluation for Patients Underwent Transapical Aortic Valve Implantation——The Initial Experience from West China hospital

    ObjectiveTo introduce the role of three dementional computed tomograph (3D-CT) for patients underwent transcatheter aortic valve implantation (TAVI) procedure in perioperative evaluation. MethodsFrom April 2014 to June 2015, we retrospectively analyzed clinical data of 28 patients with severe aortic stenosis underwent successful TAVI procedure using new second-generation device, who were enrolled in this study including 12 males and 16 females at mean age of 72.8±4.5 years. We used 3D-CT to get the perioperative relative evaluation, including valve morphology and calcification degree, annular diameter, aoronary ostium height, ascending aorta, aortic sinus diameter, left ventricular-aortic angle, optimal intraoperative angiogram projection angle. Based on the evaluation by 3D-CT image, the prosthesis size, balloon size, best intraoperative imaging projection angle and approach of apex were then chosen. ResultsAll patients with severe aortic stenosis underwent successful TAVI procedure with mean logistic Euro-SCORE I:26.2%±7.9%. CT image revealed that mean aortic annular diameter was 24.6±1.8 mm with mean valve prosthesis size 25.8±1.1 mm and pre-dilation balloon size 23.1±1.2 mm and 76.8% patients were of tricuspid aortic valve with severe calcification and 25% patients were of asymmetric calcification. Optimal intraoperative angiogram image was achieved in 92.9% patients with the help of preoperative CT image. There was a statistic difference in mean transvalvular gradient after valve implantation (54.1±15.3 mm Hg vs. 13.1±8.5 mm Hg, P<0.05). And there was no mortality or severe complication postoperatively. Conclusion3D-CT image palys an important role during perioperative evaluation of TAVI procedure and it can be helpful for Chinese doctors to operate TAVI successfully.

    Release date: Export PDF Favorites Scan
  • Diagnostic Value of MRI for Pulmonary Embolism: A Meta-Analysis

    Objective To study the diagnostic value of MRI for pulmonary embolism, so as to provide information for clinical decision. Methods The trials about MRI in the diagnosis of pulmonary embolism were searched in the following databases such as PubMed, EMbase, The Cochrane Library, CBM, CNKI and VIP. The data of the included trials were extracted, the methodological quality was evaluated in accordance with the quality assessment of diagnostic accuracy studies (QUADAS), and then meta-analysis was conducted using Meta-Disc 1.4 software. The weighted sensitivity and specificity were aggregated, as well as the summary receiver operating characteristic (SROC) curve. Further, the area under the curve (AUC) was calculated to evaluate the value of MRI in the diagnosis of pulmonary embolism. Results A total of 6 English articles involing 595 patients were included. The results of heterogeneity test revealed that there was statistical heterogeneity among the results of studies. According to the random effects model, the weighted sensitivity and specificity were 0.87 (95%CI 0.80 to 0.91), and 0.98 (95%CI 0.96 to 0.99), respectively; and the AUC was 0.988 7. Conclusion MRI is a better non-invasive method as a routine examination for pulmonary embolism. It shows fairly high sensitivity and specificity, and has a good clinical value.

    Release date: Export PDF Favorites Scan
  • Health economic evaluation between mastoid Schuller’s and Mayer’s film and high-resolution computed tomography in cholesteatoma

    Objective To evaluate the diagnosis value of temporal Done high-resolution computed tornography (HRCT) in cholesteatoma. Methods There were 30 causes that had received the mastoid surgery because of cholesteatoma. Each patient’s mastoid plain films (Schuller’s and Mayer’s ) and HRCT had been taken and compared with each other and surgical findings and evaluated with health economic evaluation methods. Results The sensitivity rate in diagnosing cholesteatoma with HRCF was much higher than that with mastoid film (Plt;0.005). The more important benefit with HRCT was that it can afford the detail information in ear such as the ossicular chain, facial nerve canal, tympanic sinus, etc. which were basis for otologist in surgery to remove the focus thoroughly and reconstruct the middle ear function at the same time. In the view of health economic evaluation, HRCT is also much better than mastoid X-ray film. Conclusion HRCT should replace masloid Schuller’s and Mayer’s film in diagnosis cholesteatoma and HRCT should use as ordinary examination in chronic otitis media.

    Release date:2016-08-25 03:17 Export PDF Favorites Scan
  • Differential Diagnosis of Inguinal Hernia and Femoral Hernia by Multi-Detector Row CT

    Objective To assess the significance of multi-detector row CT in differential diagnosis of the inguinal hernia and femoral hernia. Methods CT images which were reconstructed by multi-planer reconstruction (MPR) of 260 patients with inguinal hernia and femoral hernia who treated in our hospital form Oct. 1, 2012 to Oct. 31, 2013 were analyzed retrospectively, for exploring the relationship between sac and anatomic structure in the groin area. Results There were 146 patients with indirect hernia (75 in right, 60 in left, and 11 in bilateralism), 82 patients with direct hernia(39 in right, 34 in left, and 9 in bilateralism), and 32 patients with femoral hernia (17 in right and 15 in left). The 157sacs of patients with indirect hernia originated lateral to the inferior epigastric artery, entered the inguinal canal and through the deep ring, which mainly located anterior (103/157, 65.6%) or anteromedial (36/157, 22.9%) to the spermatic cord or round ligament. The 91 sacs of patients with direct hernia originated medial to the inferior epigastric artery, and mainly located medial to the spermatic cord (70/91, 76.9%). Sacs of both indirect hernia and direct hernia located anterosuperior to the inguinal ligament. The 32 sacs of patients with femoral hernia located posterior to the inguinal ligament and inside the “radiological femoral triangle” of coronal views. Conclusions The MPR images available from multi-detector row CT permit the accurate diagnosis of groin hernias. By using simple anatomical criteria, direct hernia, indirect hernia, and femoral hernia can be reliably distinguished.

    Release date: Export PDF Favorites Scan
  • Methods and Applications for Quantitative Measurement of Iron in Human

    Objective To summarize the methods and applications for quantitative measurement of iron in human.Methods The methods and applications for quantitative measurement of iron in human were analyzed retrospectively via reviewing the literatures domesticly and abroad, and summarized the advantages and disadvantages respectively. Results The methods for quantitative measurement of iron included laboratory tests, pathology examinations, CT, superconducting quantum interference device investigation (SQUID), and MRI. Conclusions Laboratory test is the most simple and economic method for quantitative measurement of iron in human. Percutaneous liver biopsy is the gold standardmethod. Radiologic examinations, especially MRI, may be main methods of measuring liver iron content in future.

    Release date: Export PDF Favorites Scan
  • Clinical Application of Multi-Slice Spiral CT in Portal Vein Imaging

    Objective To study the clinical significance of multi-slice spiral CT in portal vein imaging. Methods One hundred and thirty seven cases underwent enhanced scan with GE Light SpeedQX/i4 CT scanner were collected, including 41 cases of liver cancer, 20 cases of hepatic cirrhosis, 21 cases of cavernous hemangioma of liver, 9 cases of hepatic abscess, 6 cases of carcinoma of gallbladder, 14 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 5 cases in normal. The results of portal vein images were reconstructed with three-dimensional software and analyzed. Results In 109 cases, portal vein, cranial mesenteric vein, and splenic vein were demonstrated successfully in the stage of portal vein: volume rendering images were clear in 84 cases, and maximum intensity projection images and multiplanar reconstruction images were clear in 109 cases. Forty-five cases of portal hypertension, 18 cases of opened collateral circulation, 15 cases of portal vein tumor thrombus, 1 case of splenic vein tumor thrombus, and 6 cases of large cavernous hemangioma were demonstrated successfully. Conclusion The portal vein imaging with multi-slice spiral CT can show the dissection and lesions of portal vein and its branches clearly, and can provide the clinical evidence for clinicians to formulate a treatment plan correctly.

    Release date:2016-09-08 10:49 Export PDF Favorites Scan
  • Clinical Application of Artificial Pneumoperitoneum and Gastrointestinal Contrast CT Imaging in Diagnosis of Abdominal Wall Adhesion to Intestine after Operation

    ObjectiveTo explore the feasibility and safety of the artificial pneumoperitoneum and gastrointestinal contrast CT imaging, and imaging diagnostic value on abdominal wall adhesion to intestine after operation. MethodsThirtynine patients with adhesive intestinal obstruction after operation relieved by conservative therapy were included from January 2008 to November 2009. After the artificial pneumoperitoneum established by injection of gas into abdominal cavity and gastrointestinal comparison by oral administration low concentration of meglucamine diatrizoate, CT scan imaging was performed and the radiographic results were compared with surgical findings. ResultsFour patients refused surgery and discharged, so enterolysis was performed in the remaining patients. The surgical findings were consistent with radiographic results. It was showed by laparoscopic operation that intestinal obstruction caused by the fibrous adhesions and the intestine did not adhere to the abdominal wall in eight patients with fibrous adhesion diagnosed by CT. Of eighteen patients with the abdominal wall septally adhered to the intestinal, the surgical findings showed the intestine and the abdominal wall formed “M”type adhesions and omentum adhesions in sixteen patients underwent open operation, and clear fat space was showed in eight patients and close adhesion was found in another eight patients between the intestine and abdominal wall. Of thirteen patients with the abdominal wall tentiformly adhered to the intestinal, the surgical findings showed the intestine and the abdominal wall formed continuous and tentiform adhesions and omentum adhesions to the intestine in eleven patients. After the followup of 6-18 months (mean 9 months), incomplete intestinal obstruction occurred in one patient and was relieved by conservative treatment. One patient with discontinuous discomfort in abdomen after operation did not receive any treatment. The other patients were cured. ConclusionThe artificial pneumoperitoneum and gastrointestinal contrast CT imaging can accurately show the location, area, and structure composition of the postoperative abdominal wall adhesion to intestine, which is safety, simple, and bly repeatable, and a better imaging method for the diagnosing of abdominal wall adhesion to intestine after operation.

    Release date:2016-09-08 10:46 Export PDF Favorites Scan
53 pages Previous 1 2 3 ... 53 Next

Format

Content