west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CUIYuanyuan" 1 results
  • Preparation of Ti-O Film Deposited on the Surface of a New Type of Artificial Mechanical Heart Valve

    The rutile structure titanium oxide (Ti-O) film was prepared on the pure titanium material TA2 (99.999%) surface by the magnetic filter high vacuum arc deposition sputtering source. The method can not only maintain the material mechanical properties, but also improve the surface properties for better biocompatibility to accommodate the physiological environment. The preparation process of the Ti-O film was as follows. Firstly, argon ions sputtered to the TA2 substrate surface to remove the excess impurities. Secondly, a metal ion source generated Ti ions and oxygen ions by the RF discharge. Meanwhile a certain negative bias was imposed on the sample. There a certain composition of Ti-O film was obtained under a certain pressure of oxygen in the vacuum chamber. Finally, X-ray diffraction was used to research the structure and composition of the film. The results showed that the Ti-O film of the rutile crystal structure was formed under the 0.18 Pa oxygen partial pressure. A Nano scratch experiment was used to test the coating adhesion property, which demonstrated that the film was stable and durable. The contact angle experiment and the platelet clotting experiment proved that the modified surface method had improved platelet adhesion performance, and, therefore, the material possessed better biocompatibility. On the whole, the evaluations proved the modified material had excellent performance.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content