west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Cardiac valve replacement" 15 results
  • Efficacy of Salvianolate on Myocardium Protection in Extracorporeal Circulation of Cardiac Valve Replacement

    Abstract: Objective To investigate the effect of salvianolate on myocardium against ischemiareperfusion injury (IRI) in valve replacement with cardiopulmonary bypass (CPB), its outcome and mechanism, and the applicability and safety of salvianolate as a protection agent for CPB central muscles. Methods Thirty patients undergoing cardiac valve replacement were randomly divided into two groups by lot. In the control group, there were 15 patients including 5 males and 10 females, while in the 15 patients in the trial group, 7 were male and 8 were female. Salvianolate of 200 mg was given to the patients in the trial group intravenously. Hemodynamic parameters, blood gas analysis results, recovery of heartbeat, the dosage of dopamine used, and assisted ventilation time were recorded for both groups before aorta clamping, 2 h, 8 h, and 24 h after aorta declamping. Besides, ICU detention time, the amount of urine in 24 hours, and the amount of drainage in 24 hours after operation were also recorded. Blood samples were taken to determine serum cardial troponin I(cTnI), creatine kinase MB isoenzyme (CK-MB), malondialdehude (MDA), and superoxide dismutase (SOD) in both groups respectively at different times including after the induction of anesthesia, aorta opening, termination of CPB, end of operation, and one day after operation. Results There was no significant difference in hemodynamic parameters, the dosage of dopamine used, spontaneous recovery of heartbeat, and the amount of urine in 24 hours and drainage after operation for 24 hours between the two groups (Pgt;0.05). The rate of ventricular rhythm, blood lactic acid level, the time of assisted ventilation and ICU detention time for the trial group were significantly lower than those for the control group (Plt;0.05), while partial pressure of oxygen in artery(PaO2) was significantly lower in the trial group 8 h after aorta declamping (Plt;0.05). The levels of serum CK-MB, cTnI, and MDA after operation for both groups were higher than those before operation; and those levels for the trial group were significantly lower than the control group at various time points (Plt;0.05). The concentration of SOD decreased after operation in both groups (Plt;0.05), and it was higher in the trial group than the control group at different time points. The decrease of SOD level in the trial group was less than that in the control group. Conclusion Salvianolate can protect myocardium from ischemiareperfusion injury in cardiac valve replacement with CPB effectively, through promoting the activity of antioxidative enzymes and eliminating oxygen free radicals. Patients can be treated with salvianolate for antimyocardial ischemia reperfusion injury.

    Release date:2016-08-30 05:57 Export PDF Favorites Scan
  • Effects of Tight Blood Glucose Control on the Shortterm Prognosis of the Patients after Heart Valve Replacement

    Objective To investigate the effects of tight blood glucose control on the shortterm prognosis of the patients after heart valve replacement, in order to improve treatment effectiveness and lower postoperative complications. Methods A total of 240 patients including 150 males and 90 females underwent mitral valve replacement or mitral and aortic valve replacement were enrolled in this study from January 2007 to December 2008 at the cardiac surgery department of Renmin hospital of Wuhan university. The age of these patients ranged from 19 to 65 years old with an average age of 53.33 years. According to insulin administration time and blood glucose control level, they were randomly separated into two groups. In the experimental group, there were 121 patients who received continuous insulin infusion to maintain postoperative glucose level between 4.4 and 6.1 mmol/L, while 119 patients in the control group received insulin infusion when their glucose level went higher than 11.1 mmol/L to control the level between 6.1 and 11.1 mmol/L. Then the postoperative wound infection, malignant arrhythmia rate, the assisted ventilation time, intensive care unit(ICU) stay time and count of neutrophils were compared and analyzed. Results There was no hospitalized death in both groups. The rate of wound infection(3.31% vs.10.08%, χ2=4.430,P=0.035), the assisted ventilation time(9.02±2.73 h vs. 10.01±3.58 h, t=2.280,P=0.024), time for count of leukocytes to decrease to the normal level(11.04±3.16 d vs. 12.05±3.76 d, t=2.168,P=0.031), average hospitalization time(13.49±3.81 d vs. 14.51±4.02 d,t=2.017,P=0.045), and count of neutrophils on the third day(0.82±0.04 vs. 0.84±0.05, t=2.644,P=0.009) in the experimental group were significantly lower or shorter than those in the control group. But there was no significant difference between both groups in ICU stay time and the rate of malignant arrhythmia. Conclusion Tight blood glucose control can lower the rate of postoperative wound infection, shorten the assisted ventilation time and hospitalization time, and reduce the usage of antibiotics in patients after heart valve replacement. Accordingly, it can enhance the curative effect, reduce overall medical expenses, and improve prognosis.

    Release date:2016-08-30 05:59 Export PDF Favorites Scan
  • Diagnosis and Treatment for Prosthetic Valve Endocarditis

    Abstract: Objective To summarize the experiences of treatment for prosthetic valve endocarditis (PVE), paying special emphasis on some interrelated conceptions of PVE, its microbiology, diagnosis, prevention and treatment. Methods From September 1979 to September 2009, 33 patients diagnosed to have PVE were treated in our department. There were 17 males and 16 females. Their age ranged from 19 to 57 years old with an average age of 34 years. The incidence of PVE was 1.48% (33/2 236)including 1.03%(16/1 551), 3.00%(7/233), 2.28%(10/438), and 0% of PVE in mitral valve replacement (MVR), aortic valve replacement (AVR), double valve replacement (DVR), tricuspid valve replacement (TVR), respectively. Pure medical treatment (Penicillin or Vancomycin with other broadspectrum antibiotics, Fluconazole and Amphotericin) was performed on 22 patients. Combined medical and surgical treatment was performed in 11 patients. The patients underwent operation after adequate antibiotics treatment and general condition improvement. The infective tissue and vegetation were completely debrided after the infective prosthetic valve was removed. Before the new valve was transplanted, paravalvular tissue was cleaned with antibiotics, iodine solution and normal saline. Results Hospital death occurred in 19 patients (86.36%) and only 3 patients (13.64%) recovered in the group with pure medical treatment. The main reasons for death were infective shock and cardiac failure in 9 patients, and cerebral complications including embolism, bleeding and multipleorgan failure in 10 patients. For the group with combined medical and surgical treatment, 10 patients (90.91%) survived and only one patient (9.09%) died of multipleorgan failure. Follow-up was done in 13 patients for 6 months to 15 years averaging 41 months. During the follow-up, only one patient was reoperated because of the paravalvular leak eight year later. There was no PVE recurrence in all the rest patients. Conclusion Compared with pure medical treatment, combined medical and surgical treatment is a better solution for PVE.

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
  • Progress in Perioperative Treatments of Cardiac Valve Replacement during Pregnancy

    Abstract:  There is a 1% - 4% incidence of cardiac disease in pregnancy, and rheumatic heart disease is the most common diagnosis. On the condition that medical treatment is inefficacious, an open heart surgery should be performed. Because of the changes in physiological functions, there is a major difference between pregnant patients and the general population in perioperative management of valve replacement. Now , the pregnancy is not an absolute contraindication for cardiopulmonary bypass, though the incidence of mortality and birth defects remains high. It is helpful in decreasing complications and increasing survival rate by improving themethods of cardiopulmonary bypass, postoperative monitoring, anticoagulation etc. In this article, the progress in t reatments of perioperative period of cardiac valve replacement during pregnancy is reviewed.

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • The Effective Orifice Area and Haemodynamics of 19mm St. Jude Regent Valve——An Early in Vivo Study

    Abstract: Objective To investigate the in vivo effective orifice area (EOA) and whether prosthesispatient mismatch (PPM) is going to happen after 19mm St.Jude Regent valves replacement were performed. Methods Twentythree patients with valvular heart diseases were divided into 2 groups according to aortic annular diameter. 19mm St. Jude Regent valves were replaced in aortic valve place (Regent valve group), and 21mm other doubleleaflet mechanical valves were replaced in aortic place (other valves group). All of the operations were accomplished under cardiopulmonary bypass in West China Hospital. All of the patients were followed up in 3 to 6 months after their surgery processes. Color Doppler echocardiography was used to measure the hemodynamic parameters in their followup. Then left ventricular mass (LV mass), EOA and effective orifice area index (EOAI) etc. were calculated and compared by using SPSS 12.0. Results No cardiac episodes were detected during the perioperative period and 36 months after operation. LVmass reduced in 36 months after operation in both groups. No statistical significance of EOA, EOAI and LVmass reduction were detected between the two groups. Conclusions (1)The EOA and in vivo hemodynamic effects of 19mm Regent valve are similar to 21mm other double leaflet mechanical valve. (2)It is safe to use 19mm Regent valve in those patients whose aortic annular diameter are small and need double valve replacement. Using 19mm Regent valve will not cause short time cardiac episodes and PPM. (3)More further works should be done to make sure what is the standard of PPM in Chinese people, such as enlarging the patients number and prolonging the followup time. (4) Further clinical and followup works should be done to make St.Jude Regent valve’s feature out.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • Comparative Study of Efficacy Between 6-Epsilon-aminocaproic Acid and Aprotinin on Reducing Bleeding after Cardiac Valve Replacement

    Objective To compare the efficacy of 6-epsilon-aminocaproic acid (EACA) with aprotinin on reducing postoperative bleeding in cardiac valve replacement procedures, and to investigate its influence on the possible thromboembolism and the renal function. Methods Seventy-nine patients who underwent cardiac valve replacement were randomly divided into two groups: EACA group (n = 39) and aprotinin group (n = 40), which were given EACA and aprotinin separately in operations. The volumes of drainage to body surface area (BSA), blood transfusion were recorded during 24 h after operations. The concentrations of serum D-dimer and α2-antiplasmin (a2- AP) were measured before, during operation and at 72h post-operatively. The serum creatinine levels before operation and at the 72 h after operation were also measured. Results The volume ratio of drainage to BSA in EACA group was significantly higher than that in the aprotinin group at 24 h after operation (P = 0. 019). However, there was no significant difference in the volumes of blood transfusion between two groups (P〉0. 05). Also no statistical difference in the concentrations of D-dimer and a2-AP were found between two groups whether preoperatively or at 72h post-operatively (P= 0. 960,0. 485), D-dimer and a2-AP of the aprotinin group were higher than those in the EACA group after aortic off-clamping (P = 0. 001,0. 000). There was no statistically difference of △CrCl72 in both groups (P〉0. 05). No patient with thrombosis or thromboembolism was detected in two groups.Conclusion Although the efficacy of EACA in reducing postoperative bleeding in cardiac valve replacement can not compare favorably with that of aprotinin, the blood transfusion volume would not increase when EACA is used introoperatively. Proper usage of EACA will not cause thrombosis and renal damage.

    Release date:2016-08-30 06:22 Export PDF Favorites Scan
  • Research Status of Prosthesis-patient Mismatch

    Abstract:Since 1978 the definition of prosthesis-patient mismatch(PPM) was first introduced by Rahimtoola, it has attracted the attention of foreign researchers. The PPM phenomenon is concerned to be an important factor which will affect patients' survival rate and quality of life. Till now, a lot of effort should still be put on this problem. But unfortunately, this problem is still being neglected in our country. This paper is a review of PPM from it's many aspects, such as definition, current research status, prevention, and it's research prospect. We hope this paper will intensify the clinicians' knowledge on PPM.

    Release date:2016-08-30 06:23 Export PDF Favorites Scan
  • Effect of early postoperative enteral nutrition support on the levels of free amino acids in plasma for patients with cardiac valve replacement

    Objective To investigate the effect of early postoperative enteral nutrition support on the balance of free amino acid spectrum in plasma for patients with cardiac valve replacement during perioperative period. Methods (Forty-seven) patients undergoing cardiac valve replacement were divided into two groups randomly, the routine diet group and the Nutrison Fibre group. The levels of free amino acids in plasma were measured with pre-column derivatization of high-performance liquid chromatography. Results During perioperative period most free amino acids in plasma decreased significantly in the routine diet group (Plt;0.05). Despite some free amino acids in plasma decreased significantly in the Nutrison Fibre group(Plt;0.05), all free amino acids in plasma returned to (Pgt;05) or were higher than the preoperative levels in the postoperative sixth day (Plt;0.05). At the same postoperative points, most free amino acids in plasma in the Nutrison Fibre group were higher than that of the routine diet group (Plt;0.05). Conclusions The levels of free amino acids in plasma decrease significantly in patients with cardiac valve replacement after operation. Early postoperative Nutrison Fibre enteral nutrition support is helpful for keeping the balance of free amino acids in plasma for patients with cardiac valve replacement.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • Changes of the perioperative brain natriuretic peptide concentrations in patients undergoing cardiac valve replacement

    Objective To investigate the perioperative changes of serum brain natriuretic peptide (BNP) concentrations in patients undergoing cardiac valve replacement. Methods There were 20 patients admitted to the study, the serum BNP concentrations were measured before cardiac surgery, 24 hours, 7days, 14 days, and 30 days after operation. The preoperative NYHA cardiac function and the left ventricular ejection fraction(LVEF) were measured by echocardiogram. Results The preoperative BNP level was the baseline, it elevated markedly and acutely to a peak value 24 hours after operation ( P =0.003), then the BNP decreased 7 days later, but was still higher than the concentration before operation ( P =0.015), 14 days later it reached to the concentration before operation, 30 days later it was mild lower than preoperative BNP level, but there was no significant difference. There was a positive correlation between NYHA and BNP ( r =0.69, P lt;0.05), but no correlation between LVEF and BNP( r =0.29, P gt;0 05). Conclusion The preoperative serum BNP concentration can reflect the preoperative cardiac function in patients undergoing cardiac valve replacement, the high BNP level indicates the poor cardiac function. The BNP sharply elevated in the early time after operation, then gradually decreased in the late phase postoperation.

    Release date:2016-08-30 06:27 Export PDF Favorites Scan
  • Anticoagulation therapy after mechanical heart valve replacement

    Hemorrhage and thromboembolism are the most important long-term complications of anticoagulation therapy after mechanical heart valve replacement. The anticoagulation therapy intensity should be lowered in order to decrease the hemorrhagic complication. In recent years, the chief progresses of anticoagulation therapy are the using of International Normalized Ratio (INR) in anticoagulation therapy monitoring and the low intensity anticoagulation therapy. The proper anticoagulation intensities at home are INR 1.5-2.0 and prothrombin time ratio (PTR) 1.3-1.5. It is beneficial to adopt this low intensity anticoagulation therapy for decreasing the death rate from hemorrhage, protecting pregnant women and new borns from hemorrhage and malformation, and improving the life qualities of the patients.

    Release date:2016-08-30 06:27 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content