west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Computer-assisted surgery" 1 results
  • ACCURACY IMPROVEMENT OF ACETABULAR COMPONENT PLACEMENT USING NONIMAGE BASED SURGICAL NAVIGATION SYSTEM

    Objective To improve the accuracy of the acetabular component placement using the nonimage based surgical navigation system. Methods Twenty-three patients (14 males, 9 females; age, 28-55 years;26 hips)with hip disease underwent the total hip arthroplasty (THA) using the nonimage based surgicalnavigation system from February 2004 to April 2006. Rheumatoid arthritis was found in 3 patients (3 hips), necrosis of the femoral head in 6 patients (6 hips), and osteoarthritis in 14 patients (16 hips). All the patients were randomly divided into the following 2 groups: the navigated group (11 patients, 13 hips), treated by THA using the nonimage based surgical navigation system; and the control group (12 patients, 13 hips), treated by the traditional THA. According to thedesign of the study, the acetabular component was placed in the best inclination angle (45°) and the anteversion angle (15°). The postoperative component position was examined. Results No fracture, dislocation, infection or injury to the sciatic nerve was found. In the navigated group, the inclination and the anteversion reached 15.4±1.4° and 45.5±1.3°, respectively. In the control group,the inclination and the anteversion were 13.9±7.6° and 43.7±6.4°, respectively. The inclination difference was considered statistically significant (Plt;0.01). All the patients were followed up for 10-40 months,averaged 26 months. In the navigated group, the postoperative average Harris hip score was 95 (range,85-110), with an excellent result in 11 hips and a good result in 2 hips. In the control group, the postoperative average Harris hip score was 92 (range,75-110), with an excellent result in 9 hips, a good result in 3 hips, and a fair result in 1 hip. The Harris hip score difference was considered statistically significant (Plt;0.05). There was a significantly better result obtained in the navigated group than in the control group. Conclusion The acetabular component can be implanted accurately by the nonimage based surgical navigation system, which can reduce the incidence of the loosening of the prostheses and has an important value in clinical practice.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content