west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Coronary stent" 3 results
  • Safety and Effectiveness of Nicorandil for Preventing No-Reflow: A Systematic Review

    Objective To evaluate the clinical efficacy and safety of nicorandil injection for preventing slow-flow/ no-reflow phenomenon after coronary stent implantation. Methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (Issue 2, 2009), PubMed, MEDLINE, EMbase, CBM, CNKI, VIP, Wanfang database, etc. from their inception to April 2009. Some relevant journals were handsearched as well. Two reviewers independently evaluated the quality of included studies and extracted the data. Meta-analysis was performed by RevMan 5.0 software. Results Seven randomized controlled trials (RCTs) involving 630 patients were included. The results of meta-analyses showed that intracoronary and intravenous nicorandil could reduce the incidence of no-reflow/ low-flow, reduce Corrected TIMI Frame Count (CTFC), and improve left ventricular ejection fraction (LVEF). Intravenous nicorandil could reduce the incidence of ventricular tachycardia/ventricular fibrillation (VT/VF), pericardial effusion, heart failure, but couldn’t reduce the incidence of death and recurrent myocardial infarction (MI) death. Conclusion Evidence shows that intracoronary nicorandil could prevent no-reflow/ slow-flow, reduce CTFC, improve LVEF, and reduce adverse reaction in patients after coronary stent implantation. However, there is a moderate possibility of selection bias, performance bias and publication bias in this review because of the small number of the included studies, which weakens the strength of the evidence of our results. More large sample size, high-quality RCTs are needed.

    Release date:2016-09-07 11:23 Export PDF Favorites Scan
  • Drug Therapy for No-reflow Phenomenon Following Coronary Stent Implantation: A Systemic Review

    Objectives To evaluate the clinical efficacy and safety of coronary artery drug injection for slow flow/no-reflow phenomenon after coronary stent implantation. Methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 2, 2009), PubMed, EMbase, CBM, CNKI, VIP, and WanFang databases from their inception to April 2009. Two reviewers independently evaluated the quality of the included studies and extracted the data. Meta-analyses were performed by RevMan 5.0 software. Results Eight randomized controlled trials (RCTs) involving 593 patients were included. The results of meta-analyses showed that urokinase, adenosine, and anisodamine could significantly improve the thrombolysis in myocardial infartion (TIMI) flow. In addition, anisodamine could improve the coronary blood pressure. Urokinase significantly reduced the incidence of malignant ventricular arrhythmias and non-fatal of heart failure during hospitalization, but it could not change the mortality and the incidence of unstable angina, recurrence of myocardial infarction, and ischemic target revascularization. Conclusion Evidence shows that anisodamine, urokinase, urapidil and adenosine can improve TIMI flow and improve myocardial perfusion on the no-reflow patients post coronary stent implantation and urokinase can significantly reduce the incidence of main adverse cardiovascular events. Their clinical application is worthy to be advocated.

    Release date:2016-09-07 02:10 Export PDF Favorites Scan
  • Influence of bionic texture coronary stent on hemodynamics after implantation

    To explore the influence of bionic texture coronary stents on hemodynamics, a type of bioabsorbable polylactic acid coronary stents was designed, for which a finite element analysis method was used to carry out simulation analysis on blood flow field after the implantation of bionic texture stents with three different shapes (rectangle, triangle and trapezoid), thus revealing the influence of groove shape and size on hemodynamics, and identifying the optimal solution of bionic texture groove. The results showed that the influence of bionic texture grooves of different shapes and sizes on the lower wall shear stress region had a certain regularity. Specifically, the improvement effect of grooves above 0.06 mm on blood flow characteristics was poor, and the effect of grooves below 0.06 mm was good. Furthermore, the smaller the size is, the better the improvement effect is, and the 0.02 mm triangular groove had the best improvement effect. Based on the results of this study, it is expected that bionic texture stents have provided a new method for reducing in-stent restenosis.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content