west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "DAIMin" 6 results
  • EFFECT OF LANTHANUM CHLORIDE ON CYTOKINES EXPRESSION OF RAW264.7 INDUCED BY ALUMINA CERAMIC PARTICLES

    ObjectiveTo investigate the relationship between alumina ceramic particles and aseptic loosening of the joint prosthesis and the effect of lanthanum chloride on the secretion of interleukin 1β (IL-1β) and tumor necrosis factor α (TNF-α) of macrophage RAW264.7 induced by alumina ceramic particles. MethodsRAW264.7 cells were cultured in vitro and divided randomly into 4 groups according to different culture solutions:blank control group (group A),1 mg/mL alumina ceramic particles (group B),1 mg/mL alumina ceramic particles and 10 μmol/L lanthanum chloride (group C),and 10 μmol/L lanthanum chloride (group D).The cell growth was detected by MTT,and ELISA,RT-PCR,and Western blot were used to test the expressions of IL-1β,TNF-α,and nuclear factor κB (NF-κB). ResultsThere was no significant difference in cell growth among all groups by MTT (F=2.180,P=0.142).RT-PCR results showed that the expressions of IL-1β,TNF-α,and NF-κB mRNA in group B were significantly higher than those in the other 3 groups (P<0.05); the expressions in group D were significantly lower than those in group A (P<0.05).ELISA results showed that the contents of IL-1β and TNF-α in group B were significantly higher than those in the other 3 groups (P<0.05); the contents in group D were significantly lower than those in group A (P<0.05).Western blot analysis revealed that the expression of NF-κB protein in group B was significantly higher than that in the other 3 groups (P<0.05). ConclusionAlumina ceramic particles can stimulate the secretion of IL-1β and TNF-α of macrophage,and lanthanum chloride can inhibit the secretion of IL-1β and TNF-α of macrophage.

    Release date: Export PDF Favorites Scan
  • CORRELATION OF LUMBAR FACET JOINT DEGENERATION AND SPINE-PELVIC SAGITTAL BALANCE

    ObjectiveTo investigate the relationship between lumbar facet joint degeneration of each segment and spine-pelvic sagittal balance parameters. MethodsA retrospective analysis was made the clinical data of 120 patients with lumbar degenerative disease, who accorded with the inclusion criteria between June and November 2014. There were 58 males and 62 females with an average age of 53 years (range, 24-77 years). The disease duration ranged from 3 to 96 months (mean, 6.6 months). Affected segments included L3, 4 in 32 cases, L4, 5 in 47 cases, and L5, S1 in 52 cases. The CT and X-ray films of the lumbar vertebrae were taken. The facet joint degeneration was graded based on the grading system of Pathria. The spine-pelvic sagittal balance parameters were measured, including lumbar lordosis (LL), upper lumbar lordosis (ULL), lower lumbar lordosis (LLL), pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). According to normal range of PI, the patients were divided into 3 groups: group A (PI was 1ess than normal range), group B (PI was within normal range), and group C (PI was more than normal range). The facet joint degeneration was compared;according to the facet joint degeneration degree, the patients were divided into group N (mild degeneration group) and group M (serious degeneration group) to observe the relationship of lumbar facet joint degeneration of each segment and spine-pelvic sagittal balance parameters. ResultsAt L4, 5 and L5, S1, facet joint degeneration showed significant difference among groups A, B, and C (P<0.05), more serious facet joint degeneration was observed in group C;no significant difference was found in facet joint degeneration at L3, 4 (P>0.05). There was no significant difference in the other spine-pelvic sagittal balance parameters between groups N and M at each segment (P>0.05) except for PT (P<0.05). ConclusionPI of more than normal range may lead to or aggravate lumbar facet joint degeneration at L4, 5 and L5, S1;PT and PI are significantly associated with facet joint degeneration at the lower lumbar spine.

    Release date: Export PDF Favorites Scan
  • NEW ANTEROLATERAL APPROACH OF DISTAL FEMUR FOR TREATMENT OF TYPE C DISTAL FEMORAL FRACTURES

    ObjectiveTo study the effectiveness of a new anterolateral approach of distal femur in the treatment of type C distal femoral fractures by comparing with traditional lateral and anterolateral approaches. MethodsThe clinical data of 51 patients with type C distal femoral fractures treated between January 2008 and August 2011 were retrospectively analyzed. Of 51 patients, 24 patients received the new anterolateral approach of distal femur combined with fixation of condylar buttress plate (modified group), and 27 patients underwent traditional lateral or anterolateral approach combined with fixation of condylar buttress plate (traditional group). There was no significant difference in gender, age, injury cause, American Society of Anesthesiologist (ASA) classification, side, fracture type, complication, and the time from injury to operation between 2 groups (P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, hospitalization time, fracture healing time, and Hospital for Special Surgery (HSS) scores of the knee at 3, 6, and 12 months were recorded. ResultsThe operation was successfully completed and the incision healed by first intention in all patients. The operation time and frequency of intraoperative fluoroscopy of modified group were significantly less than those of traditional group (P<0.05). But the intraoperative blood loss and the hospitalization time showed no significant difference between 2 groups (P>0.05). All patients were followed up 12-37 months (mean, 21.3 months). X-ray films showed all fractures were union. The fracture healing time was (12.92±2.24) weeks in the modified group and (13.24±2.52) weeks in the traditional group, showing no significant difference (t=0.476, P=0.637). The knee HSS scores of modified group were significantly higher than those of traditional group at 3, 6, and 12 months after operation (P<0.05). There was no significant difference in the incidence of knee varus or valgus, leg length discrepancy, internal fixator loosening, flexing dysfunction of knee, traumatic arthritis of knee, and total complications between 2 groups (P>0.05). ConclusionComparing with traditional lateral and anterolateral approaches, using the new anterolateral approach to treat type C distal femoral fractures has the advantages of less damage to soft tissue, excellent exposure, less operation time, and frequency of intraoperative fluoroscopy, and better postoperative rehabilitation of knee joint.

    Release date: Export PDF Favorites Scan
  • Targeted Surveillance of Nosocomial Infection in Neurosurgical Intensive Care Unit

    ObjectiveTo analyze targeted surveillance results of nosocomial infection in Neurosurgical Intensive Care Unit (ICU) and investigate the characteristics of nosocomial infection, in order to provide reference for constituting the intervention measures. MethodsWe monitored the incidence of nosocomial infection, the application and catheter-related infection of invasive operation, and the situation of multiple resistant bacteria screening and drug resistance characteristics of each patient who stayed more than two days in neurosurgical ICU during January to December 2013. ResultsThere were a total of 1 178 patients, and the total ICU stay was 4 144 days. The nosocomial infection rate was 4.92%, and the day incidence of nosocomial infection was 13.75‰. The nosocomial infection rate was significantly higher in January and between July and December compared with other months. Ventilator utilization rate was 9.75%; ventilator-associated pneumonia incidence density was 14.85 per 1 000 catheter-days; central line utilization rate was 28.40%; central line-associated bloodstream infection incidence density was 0.85 per 1 000 catheter-days; urinary catheter utilization rate was 97.90%; and the incidence density of catheter-associated urinary tract infection was 0.25 per 1 000 catheter-days. ConclusionThe nosocomial infection rate has an obvious seasonal characteristic in neurosurgical intensive care unit, so it is necessary to make sure that the hospital infection control full-time and part-time staff should be on alert, issue timely risk warning, and strengthen the risk management of hospital infection.

    Release date: Export PDF Favorites Scan
  • CLINICAL APPLICATION OF UNILATERAL PEDICLE SCREW FOR LUMBAR INTERVERTEBRAL DISC PROTRUSION

    ObjectiveTo explore the feasibility and effectiveness of unilateral pedicle screw rod and single poly (ether-ether-ketone) (PEEK) Cage for lumbar intervertebral disc protrusion. MethodsA total of 126 cases of single segment of lumbar intervertebral disc protrusion between January 2006 and June 2012 were divided into 2 groups in the randomized clinical trial. Unilateral pedicle screw fixation and single PEEK Cage was used in 63 cases (research group), and bilateral pedicle screw fixation and single PEEK Cage in 63 cases (control group). There was no significant difference in gender, age, disease duration, side, and affected segment between 2 groups (P>0.05). Schulte evaluation criterion was used to assess bone graft fusion, Oswestry disability index (ODI) to estimate the quality of life situation, and visual analogue scale (VAS) to evaluate the improvements of lower back pain. Macnab standards was applied to assess postoperative effectiveness, and Emery ways to measure the height of intervertebral space. ResultsThe incision length, operation time, intraoperative blood loss, hospitalization time, and hospitalization fee in research group were significantly less than those in control group (P<0.05). The patients were followed up 12-79 months (mean, 21.3 months) in research group, and 15-73 months (mean, 22.6 months) in control group. The postoperative lordosis was recovered well, and the height of intervertebral space was increased. No loosening or breakage of internal fixation occurred. The time of bone graft fusion was (6.8±1.3) months in research group and was (7.1±1.2) months in control group, showing no significant difference (t=1.153, P=0.110). The height of intervertebral space, ODI score, and VAS score were significantly improved when compared with preoperative ones in 2 groups (P<0.05), but no significant difference was found between 2 groups at preoperation and last follow-up (P>0.05). At 3 months after operation, postoperative effectiveness was assessed according to Macnab criterion, the excellent and good rate was 95.23% in research group (excellent in 13 cases, good in 47 cases, and fair in 3 cases) and was 71.42% in control group (excellent in 7 cases, good in 38 cases, fair in 15 cases, and poor in 3 cases); the research group was significantly superior to control group (χ2=6.110, P=0.006). ConclusionUnilateral pedicle screw fixation and single PEEK Cage has the advantages of small trauma, reliable fixation, shorter operation time, less bleeding, less economic cost, and early off-bed activity time. It can provide a simple and reliable choice in single segmental lumbar intervertebral disc protrusion.

    Release date: Export PDF Favorites Scan
  • Lung Cancer Screening: An Overview of Systematic Reviews

    ObjectiveTo evaluate the risk of bias and reliability of conclusions of systematic reviews (SRs) of lung cancer screening. MethodsWe searched PubMed, EMbase, The Cochrane Library (Issue 2, 2016), Web of Knowledge, CBM, WanFang Data and CNKI to collect SRs of lung cancer screening from inception to February 29th, 2016. The ROBIS tool was applied to assess the risk of bias of included SRs, and then GRADE system was used for evidence quality assessment of outcomes of SRs. ResultsA total of 11 SRs involving 5 outcomes (mortality, detection rate, survival rate, over-diagnosis and potential benefits and harms) were included. The results of risk of bias assessment by ROBIS tool showed:Two studies completely matched the 4 questions of phase 1. In the phase 2, 6 studies were low risk of bias in the including criteria field; 8 studies were low risk of bias in the literature search and screening field; 3 studies were low risk of bias in the data abstraction and quality assessment field; and 5 studies were low risk of bias in the data synthesis field. In the phase 3 of comprehensive risk of bias results, 5 studies were low risk. The results of evidence quality assessment by GRADE system showed:three studies had A level evidence on the outcome of mortality; 1 study had A level evidence on detection; 1 study had A level evidence on survival rate; 3 studies on over-diagnosis had C level evidence; and 2 studies on potential benefits and harms had B level evidence. ConclusionThe risk of bias of SRs of lung cancer screening is totally modest; however, the evidence quality of outcomes of these SRs is totally low. Clinicians should cautiously use these evidence to make decision based on local situation.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content