west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "DENG Weiwu." 1 results
  • The Differential Diagnostic Value of Major Fibrinolytic Parameters in Pleural Fluid

    【Abstract】Objective To explore the differential diagnostic value of major fibrinolytic parameters in pleural fluid. Methods Tissue-type plasminogen activator( t-PA) and plasminogen activator inhibitor-1( PAI-1) in pleural fluid at the first thoracentesis were measured with ELISA and D-dimer was measured with immunoturbidimetry. Results Eighty-four patients with pleural effusion were enrolled, among which 40 with malignant effusion, 33 with infectious effusion and 11 with transudative effusion. t-PA level was higher in malignant and transudative pleural fluid than that in infectious pleural fluid[ ( 52. 49 ±31. 46) ng /mL and ( 58. 12 ±23. 14) ng /mL vs ( 37. 39 ±22. 44) ng /mL, P lt; 0. 05] , but was not statistically different between malignant pleural fluid and transudative ( P gt; 0. 05) . PAI-1 level was higher in malignant and infectious pleural fluid than that in transudative [ ( 164. 86 ±150. 22) ng/mL and ( 232. 42 ±175. 77) ng/mL vs ( 46. 38 ±16. 13) ng/mL, P lt; 0. 01] , but was not statistically different between malignant and infectious pleural fluid( P gt;0. 05) . D-dimer levels in the three types of pleural fluid were significantly different, which was ( 23. 66 ±25. 18) mg/L, ( 6. 36 ±10. 87) mg/L and ( 66. 90 ±42. 17) mg/L in malignant, transudative and infectious pleural fluid, respectively. As single-item detection for malignant pleural fluid, the cutoff of t-PA was gt; 38. 7 ng/mL( area under ROC curve was 64. 0 ) , with sensitivity of 60. 0% , specificity of 63. 6%, positive predictive value of 66. 7%, negative predictive value of 56. 8% and accuracy of 61. 6% .The cutoff of D-dimer was lt; 27. 0 mg/L( area under ROC curve was 85. 5) , with sensitivity of 84. 8% ,specificity of 72. 5% , positive predictive value of 85. 3% , negative predictive value of 71. 8% and accuracy of78.1%. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of combined examination( t-PA + D-dimer) were 92. 5% , 60. 6% , 74. 0% , 87. 0% , 78. 1% , respectively.Conclusions The t-PA, PAI-1 and D-dimer levels are significantly different in the three types of pleural fluid. The detection of fibrinolytic parameters in pleural fluid, especially the value of D-dimer,may be helpful in the differential diagnosis of pleural effusion.

    Release date:2016-09-14 11:23 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content