west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "DING Xiaohong" 2 results
  • Study on the characteristics of biology force line of proximal femur based on structural topology optimization

    Internal fixator is usually adopted in the treatment of bone fractures. In order to achieve anatomical reduction and effective fixation of fractures, the placement of internal fixators should comply with the biology force line of the bone and adapt to the specific anatomical morphological characteristics of the cortical bone. In order to investigate the distribution characteristics and formation regularity of biology force line and cortical thickness of human bone, three-dimensional model of proximal femur is established by using three-dimensional reconstruction technique in this paper. The normal physiological stress distribution of proximal femur is obtained by finite element analysis under three kinds of behavior conditions: one-legged stance, abduction and adduction. The structural topology optimization method is applied to simulate the cortex of the proximal femur under the combined action of three kinds of behavior conditions, and the anatomic morphological characteristics of the proximal femur are compared. The distribution trend of biology force line of proximal femur and the characteristics of cortex are analyzed. The results show that the biology force lines of bone structure and the morphological characteristics of cortex depend on the load of human activities. The distribution trend of biology force line is related to the direction of trabecular bone and the ridge trend and firmness of cortex when bone is loaded physiologically. The proposed analytical method provides a solution to determine the biology force line of bone and the distribution characteristics of cortex. The conclusions obtained may guide the reasonable placement of internal fixator components of fracture.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Structural design and evaluation of bone remodeling effect of fracture internal fixation implants with time-varying stiffness

    The stiffness of an ideal fracture internal fixation implant should have a time-varying performance, so that the fracture can generate reasonable mechanical stimulation at different healing stages, and biodegradable materials meet this performance. A topology optimization design method for composite structures of fracture internal fixation implants with time-varying stiffness is proposed, considering the time-dependent degradation process of materials. Using relative density and degradation residual rate to describe the distribution and degradation state of two materials with different degradation rates and elastic modulus, a coupled mathematical model of degradation simulation mechanical analysis was established. Biomaterial composite structures were designed based on variable density method to exhibit time-varying stiffness characteristics. Taking the bone plate used for the treatment of tibial fractures as an example, a composite structure bone plate with time-varying stiffness characteristics was designed using the proposed method. The optimization results showed that material 1 with high stiffness formed a columnar support structure, while material 2 with low stiffness was distributed at the degradation boundary and inside. Using a bone remodeling simulation model, the optimized bone plates were evaluated. After 11 months of remodeling, the average elastic modulus of callus using degradable time-varying stiffness plates, titanium alloy plates, and stainless steel plates were 8 634 MPa, 8 521 MPa, and 8 412 MPa, respectively, indicating that the use of degradable time-varying stiffness plates would result in better remodeling effects on the callus.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content