west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "FAN Cunyi" 10 results
  • HISTOLOGICAL STUDY ON SCIATIC NEVER REPAIR AT DIFFERENT ANGLES IN RATS

    Objective To discuss the effect of sciatic never repair at different angles on the neural regeneration in rats. Methods Seventy-two male Sprague Dawley rats were randomly divided into groups A, B, C, and D with 18 rats in each group. The right sciatic nerve was transected at 30, 45, 60, and 90° in groups A, B, C, and D, respectively, and then was repaired. The morphologic assessment of nerve regeneration was performed by gross observation, the wet weight recovery rateof gastrocnemius, histological and ultrastructural observations at 1, 2, and 3 months after operation. Results Three months later, the wet weight recovery rate of gastrocnemius, motor nerve conduction velocity and action potential of sciatic nerve, axonal diameter, medullary sheath thickness, and medullated nerve fiber counting in groups A and B were significantly better than those in groups C and D (P lt; 0.01); but no significant difference was found between group A and group B (P gt; 0.05), and between group C and group D (P gt; 0.05). Conclusion End-to-end neurorrhaphy at 30-45° can effectively promote the sciatic nerve regeneration in rats.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • IN VIVO EXPERIMENTAL STUDY ON ANTIBACTERIAL AND OSTEOGENIC CAPABILITIES OF HYDROXYAPATITE ANTIMICROBIAL COATING WITH SILVER

    Objective To investigate the antibacterial and osteogenic capabil ities in vivo of hydroxyapatite (HA)/silver (Ag) coating. Methods HA/Ag coating (Ag qual ity percentage was 3%) and HA coating were deposited to external fixator Schanz screws. The tibial fracture model was establ ished in right hindl imb of 18 adult male Beagle dogs (weighing 15-20 kg). Thetibia was stabil ized with an external fixator and 2 Schanz screws of HA coating at proximal tibia (control group, n=18) and HA/Ag coating at distal tibia (experimental group, n=18), and every screw incision was infected with Staphylococcus aureus. Infection in screw holes and the changes of bone-screw interface were observed by wound grading and X-ray films. Results In control group, wounds infection became worse with time (χ2=13.492, P=0.001), while in experimental group, no obvious change was observed (χ2=0.208, P=0.901). The wound grading of experimental group was significantly better than that of the control group at 1, 2, and 3 weeks (P lt; 0.05). Laser scanning confocal microscope showed that there was bacterial adhesion on the surface of screws in 2 groups, viable becteria mainly in control group and non-viable becteria mainly in experimental group. The scanning electron microscope (SEM) observation results of the fractured sclerous tissue section showed that an obvious transparent boundary between screw and bone in control group, but no obvious boundary in experimental group. The osseointegration ratios were 76.23% ± 15.54% in control group and 93.42% ± 5.53% in experimental group, showing significant difference (t=8.843, P=0.000). The SEM observation showed that HA/Ag coating integrated with new bone and the surface of implant was filled with new bone in experimental group; obvious interspace was seen between the HA coating and new bone in control group. Conclusion HA/Ag coating has good antibacterial and osteogenic capabil ities, so it can take effects in preventing infection in screw holes and loosening of implants.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • EFFECTS OF DIFFERENT STRESS ENVIRONMENTS ON GROWTH OF TISSUE ENGINEERING BLOOD VESSELS

    Objective To explore the influence of different stress environmentson the growth of tissue engineering blood vessels in vivo. Methods The engineering vascular scaffolds were prepared with the porcine small intestinal submucosa(SIS) wrapping vascular endothelial cells and smooth muscle cells,which were implanted into the subcutaneous tissue(subcutaneous group), the femoral quadriceps(intramuscular group), and sheathed the femoral artery(perivascular group) respectively. Four weeks postoperatively, these cultured tissues were harvested, and evaluated by macroscopic observation and histology detection. Results The cultivated tissues in different stress environments had obvious difference in respectof the tubular configuration, cellular proliferation and tissue shape. In subcutaneous group, the wall structure integrity, seed cell proliferation and SIS scaffold decomposition were poor, lumen surface was covered without endothelial cells; in intramuscular group, integrity tubular structure had formed, seed cell proliferation was found to a certain extent, lumen surface was covered with sparseendothelial cells, and a little SIS scaffold was found, cellular and fiber structured arranged irregularly; in perivascular group, vascular-like structure formed, the seed cell growth and proliferation were good, the lumen surface was completely covered with endothelial cells, the smooth muscle cells were in good morphologicaldistribution, the antihydrostatic pressure was 247.0±35 kPa,showingsignificant differences when compared with subcutaneous group(67.0±5.8 kPa) and intramuscular group(104.0±7.6 kPa) (Plt;0.01).The total scoring of tissue engineering blood vessel formation in subcutaneous group, intramuscular group and perivascular group were 5.529±0.272,8.875±0.248 and 14.824±0.253 respectively, and the differences among them were significant (P lt; 0.05). Conclusion Stress excitation has a great influence on the cellular proliferation and the growth of tissue engineering blood vessel in vivo.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Treatment of elbow joint stiffness by open release combined with distal radius fixation hinged external fixation

    ObjectiveTo observe the effectiveness of open release combined with distal radius fixation hinged external fixation for the treatment of elbow stiffness.MethodsA total of 77 patients with elbow stiffness caused by trauma were enrolled in this study between October 2014 and October 2015. The patients were divided into control group (39 cases) and observation group (38 cases) by random number table method. The patients in the observation group were treated with elbow joint opening and release combined with distal radial fixation hinged external fixation, while the control group was treated with traditional release. There was no significant difference in gender, age, disease causes, original damage diagnosis, the time from injury to operation, preoperative flexion and extension activity of elbow joint, and preoperative Mayo elbow joint function score between 2 groups (P>0.05). After operation, the function of elbow joint was evaluated by the flexion and extension activity of the elbow joint and the Mayo elbow joint function evaluation standard.ResultsThe incisions healed by first intention in 2 groups. In observation group, there were 1 case infection of nail tract, 2 cases ulnar nerve symptoms, 1 case elbow ossification, and 1 case moderate pain in the elbow; while in control group, there were 2 cases of infection of nail tract, 2 cases of ulnar nerve symptoms, and 3 cases moderate pain in the elbow. The patients in 2 groups were followed up 6 weeks to 12 months, with an average of 6 months. The flexion and extension activity of elbow joint and Mayo elbow joint function score at last follow-up were significantly improved when compared with preoperative ones (P<0.05); at last follow-up, the flexion and extension activity of elbow joint and Mayo elbow joint function score in observation group patients were significantly better than those in control group (P<0.05). According to the Mayo elbow function evaluation standard, the results were excellent in 27 cases, good in 10 cases, and fair in 1 case, with an excellent and good rate of 97.4% in observation group; and the results were excellent in 12 cases, good in 21 cases, fair in 4 cases, and poor in 2 cases, with an excellent and good rate of 84.6% in control group; showing no significant difference between 2 groups (P=0.108).ConclusionOpen release combined with distal radius fixation hinged external fixation can significantly improve the elbow function of patients with traumatic elbow stiffness, its recovery of elbow function was superior to the traditional release.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • ANTEGRADE EXTENDED PERONEAL ARTERY PERFORATOR FLAP FOR KNEE RECONSTRUCTION

    Objective To investigate the operative technique and cl inical results of repairing the soft tissue defects of knee with antegrade extended peroneal artery perforator flap. Methods From October 2007 to January 2008, 3 patients (2 men and 1 woman) with the soft tissue defects of knee were treated, with the ages of 18, 31 and 42 years, respectively. The first casesustained femur and pelvis fractures and soft tissue defect over his right popl iteal fossa, which were treated with open reduction and internal fixation (ORIF) and debridement of knee joint 2 weeks ago. The second case was necrosis of skin 3 weeks after ORIF for fracture of tibial plateau. The third case suffered from open fracture of tibial plateau and soft tissue defect, which were treated with external fixation and debridement 3 weeks ago. The defect sizes were 16 cm × 9 cm, 11 cm × 6 cm and 14 cm × 7 cm. The flap was raised by dividing the peroneal artery and veins distally and elevating them proximally, which covered for the defects of knee. The flaps were designed with the size of 18 cm × 10 cm, 12 cm × 7 cm and 15 cm × 8 cm. The pure vascular pedicle of the flap was 10 cm to 17 cm in length, including the peroneal vessels and one or two perforator branches. The donor site is covered by a spl it thickness skin graft. Results All flaps survived after surgery. The donor sites healed by first intention and the skin grafts survived. After following up for 6, 8 and 11 months, the appearance and function of the flaps were all satisfactory. Based on the modified HSS knee performance system, post-operative knee functional outcomes of three patients were excellent. Conclusion The antegrade extended peroneal artery perforator flap suppl ied by a pure vascular pedicle can be a good alternative for reconstruction of knee. The flap, with a long and thin pure vascular pedicle, could provide good texture and contour matching the recipient area.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • EXPERIMENTAL RESEARCH IN VITRO ON ANTIBACTERIAL PROPERTY AND BIOCOMPATIBILITY OF ILVERCONTAINING HYDROXYAPATITE COATING

    Objective To prepare silver-containing hydroxyapatite coating (hydroxyapatite/Ag, HA/Ag) and investigate its antibacterial property and biocompatibil ity in vitro. Methods Vacuum plasma spraying technique was adopted to prepare HA/Ag coating on titanium alloy substrate (3% Ag). After incubating the HA/Ag and the HA coating under staphylococcus aureus and pseudomonas aeruginosa suspensions of 2% tryptic soy broth (TBS) medium for 2, 4 and 7 days, respectively, the biofilm on the coatings was examined by confocal laser scanning microscope, and the bacterial density and viable bacterial percentage of bacterial biofilm were calculated. Meanwhile, the micro-morphology of bacterial biofilm was observed by SEM, the cytotoxicity was detected via MTT and the biocompatibil ity of biofilm was evaluated by acute aemolysis test. Results Compared with HA coating, the bacterial biofilm’s thickness on the surface of HA/Ag coating witnessed no significant difference at 2 days after culture (Pgt; 0.05), but decreased obviously at 4 and 7 days after culture (P lt; 0.01). The bacterial density of the biofilm increased with time, but there was no significant difference between two coatings (P gt; 0.05) at 2, 4 and 7 days after culture. The viable bacterial percentage of the biofilms on the surface of HA/Ag coating decreased obviously compared with that of HA coating at 2, 4 and 7 days after cultureP lt; 0.01). The MTT notified the cytotoxic grade of both coatings was zero. The acute haemolysis assay showed that the hemolytic rate of HA/Ag and HA coating was 0.19% and 0.12%, respectively. Conclusion With good biocompatibil ity, significant antibacterial property against staphylococcus aureus and pseudomonas aeruginosa, no obvious cytotoxicity and no erythrocyte destruction, the vacuum plasma sprayed HA/Ag coating is a promising candidate for the surface of orthopedic metal implants to improve their osseointegration and antibacterial property.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • Clinical application progress of the Sauvé-Kapandji procedure

    Objective To review the clinical application progress of the Sauvé-Kapandji procedure. Methods The indications, techniques, effectiveness, and modifications of the Sauvé-Kapandji procedure were analyzed and evaluated by an extensive review of the relevant literature. Results The Sauvé-Kapandji procedure can be applied for various disorders of the distal radioulnar joint. Risk of series of complications exist, which might be reduced by modification of the procedure. Conclusion The Sauvé-Kapandji procedure, as a salvage operation, can be a good alternative by meticulous manipulation for appropriate cases with distal radioulnar joint disorders.

    Release date:2017-09-07 10:34 Export PDF Favorites Scan
  • REPAIR OF SOFT TISSUE DEFECTS OF LOWER EXTREMITY BY USING CROSS-BRIDGE CONTRALATERAL DISTALLY BASED POSTERIOR TIBIAL ARTERY PERFORATOR FLAPS OR PERONEAL ARTERY PERFORATOR FLAPS

    Objective To discuss the feasibil ity of repairing soft tissue defects of lower extremity with a distally based posterior tibial artery perforator cross-bridge flap or a distally based peroneal artery perforator cross-bridge flap. Methods Between August 2007 and February 2010, 15 patients with soft tissue defect of the legs or feet were treated. There were 14 males and 1 female with a mean age of 33.9 years (range, 25-48 years). The injury causes included traffic accident in 8 cases, crush injury by machine in 4 cases, and crush injury by heavy weights in 3 cases. There was a scar (22 cm × 8 cm atsize) left on the ankle after the skin graft in 1 patient (after 35 months of traffic accident). And in the other 14 patients, the defect locations were the ankle in 1 case, the upper part of the lower leg in 1 case, and the lower part of the lower leg in 12 cases; the defect sizes ranged from 8 cm × 6 cm to 26 cm × 15 cm; the mean interval from injury to admission was 14.8 days (range, 4-28 days). Defects were repaired with distally based posterior tibial artery perforator cross-bridge flaps in 9 cases and distally based peroneal artery perforator cross-bridge flaps in 6 cases, and the flap sizes ranged from 10 cm × 8 cm to 28 cm × 17 cm. The donor sites were sutured directly, but a spl it-thickness skin graft was used in the middle part. The pedicles of all flaps were cut at 5-6 weeks postoperatively. Results Distal mild congestion and partial necrosis at the edge of the skin flap occurred in 2 cases and were cured after dressing change, and the other flaps survived. After cutting the pedicles, all flaps survived, and wounds of recipient sites healed by first intention. Incisions of the donor sites healed by first intention, and skin graft survived. Fifteen patients were followed up 7-35 months with an average of 19.5 months. The color and texture of the flaps were similar to these of the reci pient site. According to American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system, the mean score was 87.3 (range, 81-92). Conclusion A distally based posterior tibial artery perforator cross-bridge flap or a distally based peronealartery perforator cross-bridge flap is an optimal alternative for the reconstruction of the serious tissue defect of ontralateral leg or foot because of no microvascular anastomosis necessary, low vascular crisis risk, and high survival rate.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF BIOACTIVE CPC LOADING rhBMP-2 IN REPAIRING BONE DEFECTS

    Objective To investigate the cl inical appl ication of self-setting CPC loading rhBMP-2 for repair of bone defects and to evaluate the cl inical effect and safety. Methods From June 2006 to September 2007, 112 bone defects patients were treated by CPC loading rhBMP-2 (rhBMP-2/CPC group) or CPC (control group). The range of bone defect was from1 cm × 1 cm × 1 cm to 4 cm × 3 cm × 3 cm. In the control group, 63 patients included 31 males and 32 females, aging from 17 to 70 years with an average of 47.4 years. The bone defects were located as follows: calcaneus in 19 patients, tibial plateau in 20 patients, proximal humerus in 8 patients, distal radius in 9 patients and thoracolumbar vertebrae in 7 patients. In the rhBMP-2/CPC group, 49 patients included 31 males and 18 females, aging from 16 to 68 years with an average of 45.6 years. The bone defects were located as follows: calcaneus in 11 patients, tibial plateau in 16 patients, proximal humerus in 7 patients, distal radius in 2 patients, distal tibia in 2 patients and thoracolumbar vertebrae in 11 patients. All defects were repaired with rhBMP-2/CPC (2-5 g) and CPC (2-50 g) in the rhBMP-2/CPC group and the control group, respectively. Results A total of 108 patients got primary heal ing after operation. Incisions oozing l ight yellow fluids were found in 4 patients (control group in 1, rhBMP-2/CPC group in 3), and then healed through dressing changes and taking glucocorticoid. There were no allergic or toxic reaction, no rush or high fever, no fluctuation of hepatic and renal function, blood routine, CRP and urine routine. All patients were followed up for 12 to 24 months (mean 13.2 months). The X-ray examination showed that the implanted material was firmly bonded to the bone at the interface and the anatomic contour of the bone at the sites of defects was successfully restored, and no ablation occurred. All patients got bone union after 3 months of operation. The movement and function of flexion and extension of affected l imbs recovered to the normal level. Conclusion Repairing bone defects with rhBMP-2/CPC is safe and effective. Using rhBMP-2/CPC is a promising therapy to deal with bone defects.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • MANUFACTURE AND BIOCOMPATIBILITY STUDY OF POLY-D,L-LACTIC ACID PLATE CONTAINING rhBMP-2

    【Abstract】 Objective To investigate the manufacture and biocompatibil ity of a bioabsorbable poly-D,L-lactic acid(PDLLA) plate containing rhBMP-2. Methods rhBMP-2 was composited with PDLLA (0.05 mg/plate) through vacuum to repare PDLLA plate containing rhBMP-2. Thirty-two New Zealand rabbits (male or female) weighted (3.0 ± 0.5) kg were used in he study. A 2.5 mm middle ulna osteotomy was made bilaterally. The bones as well as periosteum were removed. The right side of all the animals was experimental side (n=32), was fixed internally by PDLLA plate containing rhBMP-2.The left side of all the animals was control side (n=32), was fixed by common PDLLA plate. After a follow-up of 2, 4, 8 and 12 weeks, the ulnas were examined visually, radiographically, histologically, and by computer graph analysis to compare the biocompatibil ity. Re sults Po rosity of PDLLA plate containing rhBMP-2 was 90%, aperture was 150 μm, tensile strength was higher than 50 MPa, three point flexural strength was higher than 90 MPa and intrinsic viscosity was 1.6 dL/g (chloroform solvent). All animals had a good heal ing 1 or 2 weeks after operation. All the animal’s diet and movement were normal. All the fractures were stable. The plates in the experimental group degraded faster than those in the control group. Relative values of callus density evaluated by X-ray at 2, 4, 8 and 12 weeks after operation in the experimental group were 39.22 ± 2.48, 48.79 ± 1.26, 63.78 ± 1.78 and 78.60 ± 1.25 respectively. Those in the control defects were 33.83 ± 1.13, 41.28 ± 1.25, 55.23 ± 0.68 and 66.54 ± 1.33. At each time point, the experimental side produced better and more trabeculae than the control side did (P < 0.01). Histological examination showed that the newbone formation in the experimental side at 2, 4, 8 and 12 weeks after operation was 0.106% ± 0.015%, 0.292% ± 0.019%, 0.457% ± 0.048% and 0.601% ± 0.037%, while those in the control side was 0, 0.193% ± 0.019%, 0.339% ± 0.029% and 0.574% ± 0.047%respectively. At each time point, the experimental side produced better new bone formation than the control side did (P lt; 0.05). The experimental side showed better compatibil ity between plates and surrounding tissue, faster bone formation, more bone regeneration mass and better medullary canal structure than the control side. Conclusion PDLLA plate containing rhBMP-2 has good biocompatibil ity and osteoinducibil ity to enhance fracture heal ing.