find Keyword "Foley catheter" 1 results
  • Clinical Analysis on 138 Cases of Removing Esophageal Foreign Bodies in Children by Utilizing Foley Catheter

    Objective To discuss the safety and effectiveness of removing esophageal foreign bodies in children by using Foley catheter. Method Retrospective analysis on the effect, operation method, complication and the types of foreign bodies of 138 cases of removing esophageal foreign bodies in children by using Foley catheter, which happened from January 1998 to January 2008 in Department of Otorhinolaryngology, the Third People’s Hospital of Chengdu. Result Among these 138 cases with esophageal foreign bodies, 126 cases (91.3%) were successfully taken out by using Foley catheter without anaesthesia, 7 cases were applied esophagoscopy under general anaesthesia, and 5 cases were cured owing to the slipping of foreign body into stomach. The operating time for Foley catheter was 5.1 minutes in average, and there’s no complicating disease in any case. The hard esophagoscope operation lasted for 15 minutes in average and one case was accompanied by dyspnea. The foreign bodies in 138 cases were coin (98 cases), button (14 cases), chess and I-go piece (13 cases), key-ring (4 cases), plastic bottle cap (3 cases), oblate battery (3 cases) and ring (3 cases), respectively. Conclusion Foley catheter is safe and effective for removing esophageal obtuse-rounded foreign bodies in children.

    Release date:2016-09-07 11:24 Export PDF Favorites Scan