目的 探讨多层螺旋CT血管成像(MSCTA)技术对下肢闭塞性动脉硬化症(ASD)的应用价值。 方法 对2007年1月-2009年12月收治的31例ASD患者进行检查,将数据在ADW4.1工作站行容积再现(VR)、最大密度投影(MIP)、多平面重组(MPR)、曲面重组(CPR)等后处理技术并结合原始图像进行综合分析。 结果 血管重建图像31例显示良好,存在不同程度的阻塞,闭塞动脉周围有代偿侧支血管。 结论 MSCTA可清楚地观察下肢动脉的血管形态及管壁的钙化斑块,狭窄程度及闭塞情况。
ObjectiveTo evaluate short-term effectiveness of revision total knee arthroplasty (TKA) with porous-coated metaphyseal Sleeve and MBT implant.MethodsA clinical data of 23 patients (24 knees) who underwent revision TKA by using porous-coated metaphyseal Sleeve combined with MBT implant between March 2015 and April 2017 was retrospectively analyzed. There were 8 males (8 knees) and 15 females (16 knees). The age ranged from 48 to 85 years (mean, 65.4 years). The cause of revision TKA included infection in 14 knees, aseptic loosening in 8 knees, instability in 1 knee, and stiff knee in 1 knee. Bone defects were classified according to the Anderson Orthopaedic Research Institute (AORI) bone defect classification. The femoral defect was rated as type ⅡA in 5 knees, type ⅡB in 17 knees, and type Ⅲ in 2 knees; the tibial defect was rated as type ⅡA in 2 knees, type ⅡB in 20 knees, and type Ⅲ in 2 knees. The mean time between primary TKA and revision TKA was 30.6 months (range, 6-86 months). The preoperative range of motion (ROM) was (56.0±24.9)°. The preoperative Hospital for Special Surgery (HSS) total score was 41.9±14.2; and the pain and function scores were 8.5±5.2 and 33.4±13.5, respectively.ResultsAll patients were followed up 12-39 months (mean, 25.6 months). The mean operation time was 2.2 hours (range, 1.6-2.9 hours). The mean intraoperative blood loss was 580 mL (range, 400-1 000 mL). There were 2 knees (8.3%) of intraoperative fracture associated with Sleeve insertion and 1 knee (4.2%) of acute postoperative infection at 25 days after revision TKA. All incisions healed by first intention. No deep venous thrombosis of lower extremity occurred. X-ray film showed that all implants were stable. At last follow-up, slight discomfort after exercise occurred in 4 knees (16.7%); end-of-stem pain in the tibia occurred in 1 knee (4.2%). The ROM was (114.6±5.1)°, which had significant improvement compared with the preoperative result (t=11.698, P=0.000). The HSS total score (89.0±10.9), pain score (26.9±6.6), and function score (62.1±5.8) also had significant improvement compared with the preoperative results (t=15.616, P=0.000; t=12.522, P=0.000; t=10.076, P=0.000).ConclusionThe porous-coated metaphyseal Sleeve combined with MBT implant in revision TKA has a significant improvement in short-term effectiveness and no signs of implant loosening.