west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "GUO Renwen" 4 results
  • Research progress in unicompartmental knee arthroplasty

    ObjectiveTo summarize the clinical application and research progress in unicompartmental knee arthroplasty (UKA).MethodsThe literature related to UKA in recent years was reviewed and the emerging indications, implant options, comparisons between other surgical techniques, and recent advances were summarized.ResultsClinical studies show that UKA has many advantages, such as less trauma, faster recovery, and fewer postoperative complications. At present, the operative indication has been expanded. The body mass index more than 25 kg/m2, less than 60 years old, patellofemoral arthritis, and anterior cruciate ligament dysfunction are no longer considered as contraindications. The prosthesis type in UKA should be selected according to the patient’s condition. In recent years, the robot-assisted UKA can effectively improve the effectiveness, improve patient satisfaction, and reduce postoperative complications.ConclusionWith the development of surgical techniques, designs of prosthesis, and the robotic technology, UKA would be further applicated. As more long-term data on UKA become available, it will further guide clinicians in counseling patients on whether UKA should be performed.

    Release date:2020-02-20 05:18 Export PDF Favorites Scan
  • A comparative study of three different fixation methods after subtrochanteric shortening osteotomy in total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of the hip

    ObjectiveTo compare the effectiveness of three different fixation methods after subtrochanteric shortening osteotomy (SSO) in total hip arthroplasty (THA) for Crowe type Ⅳ developmental dysplasia of the hip (DDH). Methods A clinical data of 63 patients (78 hips) with Crowe type Ⅳ DDH, who underwent THA with SSO between November 2014 and May 2019, was retrospectively analyzed. Among them, 18 patients (20 hips) obtained stability by intramedullary pressure provided by the S-ROM modular prostheses (group A); 22 patients (30 hips) underwent prophylactic binding by stainless steel wire after osteotomy and before stem implantation (group B); 23 patients (28 hips) were fixed with autogenous cortical strut grafts and stainless steel wire or cables (group C). There was no significant difference in gender, age, body mass index, affected limb side, and preoperative Harris score between groups (P>0.05). The operation time, complications, imaging results, hip functional score of the three groups were recorded and compared. Results There was no significant difference in the operation time between groups (P>0.05). All incisions healed by first intention. All patients were followed up, and the follow-up time was 2.5-4.0 years (mean, 3.1 years) in group A, 1.5-5.5 years (mean, 3.2 years) in group B, and 1.0-5.0 years (mean, 1.6 years) in group C. There was no significant difference in Harris score or Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score between groups at 4 and 12 months after operation (P>0.05). X-ray films showed that there was no significant difference in osteotomy healing rate at 4, 8, and 12 months after operation and the osteotomy healing time between groups (P>0.05). There was no complications such as joint dislocation, prosthesis loosening, prosthetic joint infection, or heterotopic ossification during follow-up, except for the distal femoral fracture of 1 hip during operation in group B. Conclusion In THA for patients with Crowe type Ⅳ DDH, the stainless steel wire binding alone and autogenous cortical strut grafts combined with stainless steel wire or cable binding can not significantly promote the osteotomy healing compared with femoral prosthesis intramedullary compression fixation. For patients with nonmatched medullary cavity after SSO, it is recommended to apply autogenous cortical strut grafts with wire or cables for additional fixation.

    Release date: Export PDF Favorites Scan
  • Application of preoperative digital-template planning in total hip arthroplasty via direct anterior approach

    ObjectiveTo investigate the accuracy of preoperative digital-template planning in total hip arthroplasty (THA) via direct anterior approach (DAA) and its effect on the short-term effectiveness.MethodsThe clinical data of 77 patients (109 hips) with osteonecrosis of femoral head who underwent THA via DAA between January 2016 and May 2018 was retrospectively analyzed. According to the type of template, patients were divided into digital-template group (group A, 40 patients, 56 hips) and conventional-template group (group B, 37 patients, 53 hips). There was no significant difference in age, gender, body mass index, the stages of osteonecrosis of femoral head, and preoperative Harris hip score (HHS) (P>0.05). The operation time, intraoperative blood loss, frequencies of intraoperative fluoroscopy, and complications were recorded. Otherwise, the consistency rate of preoperative planning and practical prosthesis size was analyzed. Position of acetabular prosthesis and femoral prosthesis alignment were measured on anteroposterior X-ray film of the pelvis at 3 months after operation. HHS was used to evaluate clinical function.ResultsThe consistency rate of preoperative planning and practical acetabular prosthesis size was significantly higher in group A (80.4%, 45/56) than that in group B (62.3%, 33/53), showing significant difference (χ2=4.38, P=0.04). But there was no significant difference in the consistency rate of preoperative planning and practical femoral prosthesis size between group A (83.9%, 47/56) and group B (79.2%, 42/53)(χ2=0.40, P=0.53). The prosthesis abductions were (40.7±6.4)° in group A and (38.8±7.3)° in group B; the femoral prosthesis alignment deviations were (0.1±1.8)° in group A and (0.3±1.7)° in group B. There was no significant difference in the prosthesis abduction and femoral prosthesis alignment deviation between 2 groups (P>0.05). No prosthesis sinking or loosening occurred during follow-up. The operation time and frequencies of intraoperative fluoroscopy were less in group A than those in group B (P<0.05). But there was no significant difference in intraoperative blood loss between 2 groups (t=1.92, P=0.06). The complication occurred in 1 hip of group A and 6 hips of group B, with no significant difference (P=0.06). All patients were followed up 6-22 months (mean 13.8 months) in group A and 6-24 months (mean, 14.6 months) in group B. At last follow-up, the HHS scores were 91.8±3.1 in group A and 92.6±4.2 in group B, and the difference was not significant (t=1.14, P=0.26).ConclusionPreoperative digital-template planning in THA via DAA is accurate, which can reduce the operation time and frequencies of intraoperative fluoroscopy without enhancing the risk of complication.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
  • Measurement and analysis of leg length in adults with unilateral developmental dysplasia of the hip

    ObjectiveTo measure and analyze the radiographic characteristics of the leg length discrepancy in adult patients with unilateral developmental dysplasia of the hip (DDH).MethodsThe clinical data of 112 patients with unilateral DDH who met the selection criteria between January 2016 and June 2018 were retrospectively analyzed. There were 16 males and 96 females with an age of 20-76 years (mean, 42.9 years). According to the Crowe classification, there were 25 hips of type Ⅰ, 26 hips of type Ⅱ, 15 hips of type Ⅲ, and 46 hips of type Ⅳ (26 hips of type ⅣA without secondary acetabular formation, and 20 hips of type ⅣB with secondary acetabular formation). Full-length X-ray films of the lower limbs in the standing position were used to measure the following parameters: greater trochanter leg length (GTLL), greater trochanter femoral length (GTFL), lesser trochanter leg length (LTLL), lesser trochanter femoral length (LTFL), tibial length (TL), and intertrochanteric distance (ITD). The above parameters on the healthy and affected sides were compared and the difference of each parameter between the healthy and affected sides was calculated. Taking the difference of 5 mm between the healthy side and the affected side as the threshold value, the number of cases with the healthy side was greater than 5 mm and the affected side was greater than 5 mm were counted respectively. The difference of the imaging parameters between the healthy side and the affected side were compared between different Crowe types and between type ⅣA and type ⅣB.ResultsThere was no significant difference in GTLL and LTFL between healthy and affected sides (P>0.05); LTLL and TL of affected side were longer than healthy side, GTFL and ITD were shorter than healthy side, and the differences were significant (P<0.05). The constituent ratio of long cases on the affected side of TL and LTLL was greater than the constituent ratio of long cases on the healthy side, while the constituent ratio of long cases on the healthy side of GTFL and ITD was greater than the constituent ratio of long cases on the affected side; there was no obvious difference in the constituent ratio of long cases on the healthy side or the affected side of GTLL and LTFL. The comparison between different Crowe types showed that only the difference in TL between type Ⅰ and type Ⅳ was significant (P<0.05), the difference of each imaging parameter among the other types showing no significant difference (P>0.05). Compared with type ⅣB, the differences of GTLL, TL, and ITD of type ⅣA were bigger, and the differences were significant (P<0.05); the differences of other parameters between type ⅣA and type ⅣB were not significant (P>0.05).ConclusionIn adult unilateral DDH patients, the leg length on the healthy side and the affected side is different, and the difference mainly comes from the TL and ITD, which should be paid attention to in preoperative planning.

    Release date:2021-06-07 02:00 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content