west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "GUO Shengjie" 2 results
  • Progress in the method of tibial prosthesis rotation alignment in total knee arthroplasty

    ObjectiveTo summarize the methods of tibial prosthesis rotation alignment in total knee arthroplasty, and provide reference for clinicians to select and further study the methods of tibial prosthesis rotation alignment.MethodsThe advantages and disadvantages of various tibial prosthesis rotation alignment methods were analyzed and summarized by referring to the relevant literature at home and abroad in recent years.ResultsThere are many methods for tibial prosthesis rotation alignment, including reference to relevant anatomical landmarks, range of motion (ROM) technique, computer-assisted navigation, and personalized osteotomy. The inner one-third of the tibial tuberosity is a more accurate reference anatomical landmark, but the obesity, severe knee deformity and dysplasia have impacts on the precise placement of the tibial prosthesis. ROM technique do not need to refer to the anatomical landmark of the tibia, and aren’t affected by landmark variation. It can be used for severe knee valgus deformity and the landmarks that are difficult to identify. However, it may cause internal rotation of tibial prosthesis. Computer- assisted navigation and personalized osteotomy can achieve more accurate alignment in sagittal, coronal, and rotational alignment of femoral prosthesis. However, due to the lack of reliable anatomical landmarkers related to tibia fixation, it is still controversial whether it can help the alignment of tibial prosthesis rotation.ConclusionThe surgeon should master the methods of rotation and alignment of tibial prosthesis, make preoperative plans, select appropriate alignment methods for different patients, and achieve individualization. Meanwhile, several anatomical landmarkers should be referred to properly during the operation, which can be used to detect the correct placement of tibial prosthesis and avoid large rotation error.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Short-term effectiveness of novel computer navigation system assisted total knee arthroplasty

    ObjectiveTo investigate the short-term effectiveness of novel computer navigation system (Knee 3 software; Brainlab, Germany) assisted total knee arthroplasty (TKA).MethodsBetween July 2020 and December 2020, 19 patients underwent unilateral TKA assisted with Knee 3 software. There were 4 males and 15 females. The mean age was 66.3 years (range, 52-79 years). Eighteen patients were diagnosed with osteoarthritis and 1 patient with rheumatoid arthritis. Sixteen patients had varus knees and 3 patients had valgus knees. Preoperative Western Ontario and McMaster University Osteoarthritis Index (WOMAC) pain, stiffness, function, and total scores were 12.4±3.4, 2 (1, 4), 22 (18, 29), and 37 (29, 43), respectively. Intraoperatively, the medial and lateral gaps in knee extension and in 90° of knee flexion were recorded. The operation time, intraoperative blood loss, blood transfusion, and complications were recorded. The hip-knee-ankle angle (HKA), lateral distal femoral angle, and medial proximal tibial angle were measured to evaluate lower limb alignment and prostheses’s alignment using X-ray films at 6 weeks after operation. Patient’s satisfaction rate and WOMAC pain, stiffness, function, and total scores were investigated.ResultsEighteen patients (94.7%) had medial- lateral gap balancing in knee extension, 18 patients (94.7%) had medial-lateral gap balancing in 90° of knee flexion, 19 patients (100%) had medial gap balancing between knee extension and 90° of knee flexion, and 18 patients (94.7%) had lateral gap balancing between knee extension and 90° of knee flexion. The mean operation time was 126 minutes (range, 100-200 minutes). The mean intraoperative blood loss was 205 mL (range, 100-400 mL). Patients were followed up 4-8 months, with an average of 6.2 months. Postoperative complications included 1 deep vein thrombosis of lower extremities and 1 cerebral infarction. X-ray films showed that the mean HKA, lateral distal femoral angle, and medial proximal tibial angle were 179.8° (range, 178°-182°), 83.5° (range, 80°-87°), and 89.5° (range, 87°-93°), respectively. At last follow-up, WOMAC pain, stiffness, function, and total scores were 3.6±1.9, 0 (0, 2), 4 (2, 6), and 9 (5, 10), respectively, which improved when compared with preoperative scores (P<0.05). Twelve patients were very satisfied with the operation results and 7 patients were satisfied with the operation results. The overall satisfaction rate was 100%.ConclusionKnee 3 software can help to obtain good gap balancing and optimal lower limb alignment, with high patient’s satisfaction and good short-term effecectiveness.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content