west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HU Xiaopeng" 5 results
  • Clinical Application of Homemade Flexible Annuloplasty Ring in Mitral Valve Repair

    Abstract: Objective To summarize the clinical results of homemade flexible annuloplasty ring in mitral valve repair, in order to discuss the appropriate ring size. Methods Sixtysix patients (55 males,and 11 females with a mean age of 44.62±15.94 years) with mitral insufficiency underwent mitral valve repair with homemade flexible annuloplasty ring from April 2002 to November 2009 in Fu Wai Hospital. In order to choose the ring with an appropriate size, we made and kept to the following principles: if the intercommissural distance was bigger than size 30, we chose a ring 2size smaller; if the measured distance was smaller than size 30, 1size smaller ring would be chosen. Patients were followed by echocardiography to observe the mitral valve function. Results All patients were cured and discharged from the hospital. The results of echocardiography showed mild to moderate regurgitation in 1 patient, mild regurgitation in 11 patients, and normal mitral function or trace regurgitation in the rest 54 patients. Mitral valve forward velocity was 1.40±0.30 m/s with no mitral stenosis or systolic anterior motion (SAM) of the anterior mitral leaflet. Fiftyone patients were followed up from 2 months to 7 years(24.60±25.90 months). The results of echocardiography on 38 patients showed that 1 patient had moderate regurgitation, 5 patients had mild to moderate regurgitation, 9 patients had mild regurgitation and others had normal mitral function or trace regurgitation. For these 38 patients included in the followup study, mitral valve forward velocity was 1.50±0.40 m/s with no mitral stenosis, SAM or left ventricular outlet tract obstruction. During the followup, the left atrium size (43.19±10.48 mm vs. 48.59±9.40 mm, t=4.524, P=0.000) and left ventricular end diastolic diameter (52.64±7.35 mm vs. 6269±8.77 mm, t=7.607, P=0.000) decreased significantly than the preoperative size and diameter respectively.  The application of restrictive homemade flexible annuloplasty ring in mitral valve annuloplasty had satisfactory, durable and stable clinical results.

    Release date: Export PDF Favorites Scan
  • Extraanatomic Aortic Bypass Grafting Through Median Sternotomy for Onestage Treatment of Aortic Coarctation and Associated Cardiac Diseases

    Objective To summarize the experience of extraanatomic aortic bypass grafting through median sternotomy for onestage treatment of aortic coarctation and associated cardiac diseases, and to improve surgical effect of the diseases. Methods Between July 1997 and July 2008, 31 consecutive patients(20 male,11 female; age 31.9±11.7 years) with aortic coarctation and associated cardiac anomalies underwent onestage surgical repair through median sternotomy. The associated cardiac anomalies included: aortic valve insufficiency or stenosis(n=22); mitral valve insufficiency or stenosis (n=9); patent ductus arteriosus (n=5); ascending aortic aneurysm (n=4); ventricular septal defect (n=3); coronary artery disease (n=2). Extra-anatomic aortic bypass grafting was used to repair the coarctation. Routing of the grafts was: ascendingto posterior pericardial descending aorta (n=9) and ascendingtoinfrarenal abdominal aorta (n=22). Concomitant cardiac procedures included: aortic valve replacement in 16; Bentall procedures in 6; mitral valve repair or replacement in 9; ascending aortic replacement or aortoplasty in 4; patent ductus arteriosus closure in 5; ventricular septal defect closure in 3 and coronary artery bypass grafting in 2. Results One patient died of septic shock 39 days after operation with an inhospital mortality of 3.2%. Mean systolic blood pressure gradient between upper and lower extremities decreased from 64.2±25.3 mm Hg preoperatively to 13.7±10.2 mm Hg postoperatively (Plt;0.05). Twentyseven patients were followed up from 4 to 73 months, there were no late deaths,reoperations or graftrelated complications. Conclusion Extraanatomic aortic bypass grafting can be performed simultaneously through median approach in patients with aortic coarctation and associated cardiac diseases. It is an effective and safe treatment option for onestage surgical repair in adults and adolescents. Both ascendingto posterior pericardial descending aorta and ascendingtoinfrarenal abdominal aorta bypass have favorable results.

    Release date:2016-08-30 06:06 Export PDF Favorites Scan
  • Diagnosis and Surgical Treatment of Primary Pulmonary Artery Tumor

    Abstract: Objective To investigate the clinical features, differential diagnosis, surgical treatment and outcome of primary pulmonary artery sarcoma. Methods Between January 1994 and December 2004, 5 patients with primary pulmonary artery sarcoma were identified at operation and treated by surgical resection. Pulmonary valve stenosis were initially diagnosed in 3 patients, and chronic pulmonary embolism were initially diagnosed in 2 patients. Tumor resection from the vascular bed was performed in 1 patient and tumor resection and homograft reconstruction of pulmonary arteries were performed in 4 patients. Results One patient died of postoperative refractory pulmonary hypertension, 2 patients died 4 months after operation because of brain metastases, 1 patient was alive for 9 months after operation with recurrent pulmonary tumor, and 1 patient was alive for 2 years after operation without clinical or radiological signs of tumor recurrence or metastasis. Histological examinations showed 4 malignant mesenchymomas and 1 fibrosarcoma. Conclusions Primary pulmonary artery sarcomas are rare and usually fatal tumors of the cardiovascular system. The diagnosis is difficult and this disease is frequently misdiagnosed as chronic pulmonary hromboembolism and pulmonary valve stenosis. Early diagnosis can be improved by computerized tomography scanning and magnetic resonance imaging. Radical surgical resection was the most effective modality for shortterm palliation. The prognosis of pulmonary artery sarcoma is poor. The survival time after resection varies from several months to several years depending on the presence of recurrence or metastasis.

    Release date:2016-08-30 06:13 Export PDF Favorites Scan
  • Contrast-zero ultrasound-guided transcatheter aortic valve replacement: A case report

    Conventional transcatheter aortic valve replacement is normally recommended with transthoracic echocardiography, and contrast agent mediated fluoroscopy under anesthesia to guide a better implantation of the transcatheter valve. However, iodine-containing contrast agent possibly damages the patient’s kidney, and even induces the acute kidney injury. We reported a 75-year-old patient diagnosed with severe aortic valve stenosis, moderate regurgitation, and chronic renal failure. We performed the aortic valve replacement under the guidance of fluoroscopy and transesophageal ultrasound without contrast agent. Seven days after surgery, the patient recovered well and discharged with alleviated aortic stenosis and fixed transcatheter aortic valve.

    Release date: Export PDF Favorites Scan
  • Primary practice of transcatheter edge-to-edge repair for mitral regurgitation: Early results of MitraClip in multiple centers

    ObjectiveTo investigate the early clinical results of MitraClip system in domestic patients. Methods We retrospectively analyzed the clinical data of 36 patients who underwent transcatheter edge-to-edge repair procedure using MitraClip system in Beijing Fuwai Hospital, Shenzhen Fuwai Hospital and Fuwai Yunnan Cardiovascular Hospital between January and June 2021. There were 24 males and 12 females, with a median age of 70 (47-86) years. Ten (27.8%) patients had 3+ mitral regurgitation (MR) and 26 (72.2%) patients had 4+ MR preoperatively. ResultsAll procedures were successfully performed. The reduction in MR was 2+ at least immediately after surgery, and 91.7% of patients had MR≤2+ at 3 days postoperatively. There was no statistical difference in left ventricular ejection fraction change postoperatively. Forward velocity and peak gradient of mitral valve were increased after the procedure. Mean gradient of mitral valve were increased at 3 days postoperatively than immediately after surgery (P<0.001). Two patients had acute pericardial effusion intraoperatively, and received pericardial puncture and drainage immediately. ConclusionMitraClip system has been applied well in domestic patients and can significantly improve MR. This sutdy has a good consistency with foreign studies, and the early results are satisfactory.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content