west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HUANG Liqun" 2 results
  • EFFECT OF LOW FREQUENCY PULSED ELECTROMAGNETIC FIELDS ON LUMBAR BONE HISTOMORPHOMETRY IN OVARIECTOMIZED OSTEOPOROSIS RATS

    Objective To investigate the changes of lumbar bone histomorphometry after exposure to low frequency pulsed electromagnetic fields (PEMFs), and to further understand the effect of PEMFs on osteoporosis (OP) in ovariectomizedOP rats. Methods Sixty-six 3-month-old Sprague Dawley rats were randomly divided into 4 groups: group A(n=12), groupB (n=12), group C (n=12), and group D (n=30). In group A, the ovaries were not resected as sham-ovariectomy; in groupsB, C, and D, the ovaries were resected. At 12 weeks after ovariectomy, the rats were exposed to PEMFs at 8 Hz, 3.8 mT, and 40 minutes/ day for 30 days in group B; the rats were administered with premarin [0.065 mg/(kg·d) by gavage for 30 days] in group C; in group D, the rats were housed as ovariectomy control. The hair and activity of rats were observed; the levels of serum estradiol were determined. At 30 days after intervention, all rats were sacrificed to harvest the L4 vertebrae for bone histomorphometry. Results General observation showed hair loss and decreased activity in group D, and no abnormal appearances in groups A, B, and C. The level of serum estradiol in group A was significantly higher than that in group D [(54.93 ± 23.52) pg/mL vs. (31.99 ± 23.45) pg/mL] (t=2.345, P=0.029). Histological observation showed thinness of sclerotin, bigger medullary cavity, and sparse and thinner bone trabecula in group D; uniform bone trabecula with no breakage in groups A, B, and C at 30 days after intervention. The ratio of trabecular bone area in group B was significantly higher than that in group D (P lt; 0.05); it was higher than that in groups A and C, showing no significant difference (P gt; 0.05). The trabecular thickness in group B was significantly higher than that in group D (P lt; 0.05), but it was lower than that in groups A and C, showing no significant difference (P gt; 0.05). The trabecular number in group B was significantly lower than that in group D (P lt; 0.05), but it was higher than that in groups A and C, showing no significant difference (P gt; 0.05). The trabecular separation in group B was higher than that in group D and lower than that in groups A and C, showing no significant difference (P gt; 0.05). Conclusion PEMFs at 8 Hz and 3.8 mT can significantly improve the character of bone microstructure in ovariectomized OP rats, increase the ratio of bone trabecular area and trabecular thickness, and decrease the trabecular number.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • EFFECT OF PULSED ELECTROMAGNETIC FIELDS OF DIFFERENT TREATMENT TIME ON BONE MINERALDENSITY OF FEMUR IN OVARIECTOMIZED RATS

    To observe the effect of pulsed electromagnetic fields (PEMFs) of different treatment time on bone mineral density of femur in ovariectomized rats, so as to find out the treatment time for the best therapeutic efficacy. Methods Fifty female SD rats were randomly divided into 5 groups: sham-ovariectomized (SHAM) group (no PEMFs treatment), ovariectomy (OVX) control group (no PEMFs treatment), OVX I, II and III groups (PEMFs treatment at 8 Hz frequency with 3. 8 ×10-10A/m intensity 20, 40, and 60 minutes daily for 30 days, respectively). All rats were given bilateral ovariectomy except those in the SHAM control group. Bone mineral density (BMD) of femur was assessed at 30 days after PEMFs treatment. Results In OVX control group, hypotrichosis, hypoactivity and l istlessness were observed after operation; and in SHAM group, OVX I group, OVX II group and OVX III group, pilus, psyche and activity were normal. The BMD values were (0.226 ± 0.011), (0.210 ± 0.011), (0.231 ± 0.013), (0.231 ± 0.017) and (0.229 ± 0.013) g/cm2 in SHAM group, OVX control group, OVX I group, OVX II group and OVX III group respectively, showing significant differences between OVX control group and other groups (P lt; 0.05), but showing no significant differences between other 4 groups (P gt; 0.05). Conclusion P EMFs of the three different treatment times can maintain the BMD in ovariectomized rats. It shows that PEMFs have the same effect of maintaining BMD with increasing of treatment time at the range of 20-60 minutes in ovariectomized rats.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content