west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Individualized" 18 results
  • Single Nucleotide Polymorphism and Chemotherapy Response of Breast Cancer

    Objective To investigate the relationship between single nucleotide polymorphism (SNP) and therapy response of some conventional chemotherapy drugs in breast cancer, and to explore the value of SNP in guiding individualized treatment. Methods Pub-Medline and Chinese CHKD periodical electronic databases were searched. Representative researches in this field were sorted out and concluded. Results Varied genes related to drug metabolism have SNP phenomenon, which are closely associated with interindividual diversity in drug response. Race, section, environment, and drug-drug or gene-gene interactions may have effect on the association.Conclusion The study on SNP has important application prospect in optimizing the individual drug-delivery. However, the combinatorial analyses of multi-SNPs and multi-genes and the prospective studies with large-scale samples and random controls are still needed.

    Release date: Export PDF Favorites Scan
  • Individualized Protamine Reduces Postoperative Blood Loss after Open Heart Surgery Undergoing Cardiopulmonary Bypass

    Abstract: Objective To compare individualized protamine with protamine based on weight in terms of postoperative bleeding and blood transfusion dose, in order to reduce postoperative bleeding complications. Methods Forty adult patients scheduled to elective open heart surgery under cardiopulmonary bypass (CPB) were randomly divided into two groups. For patients in the experimental group, we gave them protamine based on heparinprotamine titration result, while patients in the control group received the same amount of protamine as the heparin administered before operation. Pleural drainage and required transfusion were recorded at 1, 2 and 24 hours after surgery. Results Protamine dose given to the experimental group was significantly higher than the control group (Plt;0.05), while pleural drainage was significantly lower at 1 h(180±83 ml vs. 285±156 ml,P=0.012), 2 h (74±31 ml vs. 114±44 ml,P=0.002), and 24 h (465±167 ml vs. 645±207 ml,P=0.004) than that in the control group after surgery, and the required red blood cell suspension was also significantly lower than the control group (0.15±0.27 U vs.0.80±0.96 U,P=0.018). Conclusion Compared with protamine dose based on heparin administered before CPB, individualized protamine based on titration can reduce postoperative pleural drainage (blood loss) and red blood cell suspension requirement. 

    Release date:2016-08-30 06:01 Export PDF Favorites Scan
  • VALIDATION STUDY ON PRECISION OF DIGITIZED CUSTOM-MADE RADIAL HEAD PROSTHESIS BY THREE-DIMENSIONAL VISUALIZATION OF VIRTUAL SURGERY

    Objective To study digitize design of custom-made radial head prosthesis and to verify its matching precision by the surgery of preoperative three-dimensional (3-D) virtual replacement. Methods Six healthy adult volunteers (3 males and 3 females, aged 25-55 years with an average of 33 years) received slice scan of bilateral elbow by Speed Light 16-slice spiral CT. The CT Dicom data were imported into Mimics 10.0 software individually for 3-D reconstruction image, and the left proximal radial 3-D image was extracted, the mirror of the image was generated and it was split into 2 pieces: the head and the neck. The internal diameter and the length of the radial neck were obtained by Mimics 10.0 software measurement tools. In Geomagic Studio 12 software, the radial head was simulated to cover the cartilage surface (1 mm thickness) and generated to an entity. In UG NX 8.0 software, the stem of prosthesis was designed according to the parameters above and assembled head entity. Each custom-made prosthesis was performed and verified its matching precision by the surgery of preoperative 3-D virtual replacement. Results Comparing the morphology of 6 digitize custom-made prostheses with ipsilateral radial heads by the 3-D virtual surgery, the error was less than 1 mm. The radial head prosthesis design on basis of the contralateral anatomy was verified excellent matching. Conclusion The 3-D virtual surgery test and the digitized custom-made radial head prosthesis will be available for clinical accurate replacement.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • Individualized Assessment Method of Evidence-Based Goal Attainment Scale Produced in TCM

    To aim directly at the individualized character and tendency about clinical assessment of Traditional Chinese Medicine (TCM), we draw off a new pathway which is evidence-based goal attainment scale(EBGAS) in the text. i.e., we will develop clinical individualized assessment method of TCM on account of GAS by the approach of evidence based medicine.

    Release date:2016-09-07 02:16 Export PDF Favorites Scan
  • Multiple Minimally Invasive Therapy and Individualized Treatments Combination for Patients with Severe Acute Pancreatitis

    Objective To evaluate the efficacy of multiple minimally invasive therapy and individualized treatments combination in severe acute pancreatitis. Methods The data of sixty-seven patients with severe acute pancreatitis between September 1998 and October 2008 undergoing multiple minimally invasive therapy and individualized treatments were analyzed retrospectively. The changes of APACHE Ⅱ score, CT score, WBC count, total bilirubin, AST, blood glucose, amylase, lypase, C-reactive protein, tumor necrosis factor-α, blood urea nitrogen, creatinine, and oxygenation index (PaO2/FiO2) were observed and compared between before and after treatment. Time of abdominal pain relieved, laparotomy rate, mortality rate, recovery rate, hospital stay, and cost of hospitalization were also observed. Results All the detected indexes improved significantly after treatments compared with those before treatments (Plt;0.001). Time of abdominal pain relieved was (20.17±14.16) h. Laparotomy rate was 6.0% (4/67). Mortality rate was 7.5% (5/67). Recovery rate was 92.5% (62/67). Hospital stay was (30.85±28.37) d and cost of hospitalization was (59 295.78±34 564.44) yuan. Conclusions Multiple minimally invasive therapy and individualized treatments for cases of severe acute pancreatitis with different causes, course, severity of disease, and complications, could significantly improve the clinical indexes and recovery rate of severe acute pancreatitis.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
  • Impact of Individualized Diabetes Education Prescription on Glycemic Control in Out-patients with Diabetes

    ObjectiveTo explore the effect of individualized health education prescription on glycemic control in out-patients with diabetes. MethodBetween January and May 2014, seventy-three out-patients with diabetes were given individualized health education prescription for 6 months. The we observed the change of HbA1c level, HbA1c standard rate and medication compliance of the patients. ResultsBefore the use of individualized health education prescription, HbA1c was (8.10±1.86)%, and HbA1c was (6.55±1.26)% after the intervention (P<0.001). HbA1c standard rate (72.6%) and medication compliance (the number of patients with high, medium, and poor compliance was 36, 27, and 10, respectively) after the intervention were both significantly better than those before (16.4%; 12, 42, and 19) the intervention (P<0.001). ConclusionsEducation prescription is effective in the management of blood glucose for patients with diabetes.

    Release date: Export PDF Favorites Scan
  • APPLICATION OF THREE-DIMENSIONAL PRINTING TECHNIQUE IN REPAIR AND RECONSTRUCTION OF MAXILLOFACIAL BONE DEFECT

    ObjectiveTo explore the application of three-dimensional (3-D) printing technique in repair and reconstruction of maxillofacial bone defect. MethodsThe related literature on the recent advance in the application of 3-D printing technique for repair and reconstructing maxillofacial bone defect was reviewed and summarized in the following aspects:3-D models for teaching, preoperative planning, and practicing; surgical templates for accurate positioning during operation; individual implantable prosthetics for repair and reconstructing the maxillofacial bone defect. Results3-D printing technique is profoundly affecting the treatment level in repair and reconstruction of maxillofacial bone defect. Conclusion3-D printing technique will promote the development of the repair and reconstructing maxillofacial bone defect toward more accurate, personalized, and safer surgery.

    Release date: Export PDF Favorites Scan
  • APPLICATION OF DIGITAL DESIGN AND THREE-DIMENSIONAL PRINTING TECHNIQUE ON INDIVIDUALIZED MEDICAL TREATMENT

    ObjectiveTo summarize the latest research development of the application of digital design and three-dimensional (3-D) printing technique on individualized medical treatment. MethodsRecent research data and clinical literature about the application of digital design and 3-D printing technique on individualized medical treatment in Xi'an Jiaotong University and its cooperation unit were summarized, reviewed, and analyzed. ResultsDigital design and 3-D printing technique can design and manufacture individualized implant based on the patient's specific disease conditions. And the implant can satisfy the needs of specific shape and function of the patient, reducing dependence on the level of experience required for the doctor. So 3-D printing technique get more and more recognition of the surgeon on the individualized repair of human tissue. Xi'an Jiaotong University is the first unit to develop the commercial 3-D printer and conduct depth research on the design and manufacture of individualized medical implant. And complete technological processes and quality standards of product have been developed. ConclusionThe individualized medical implant manufactured by 3-D printing technique can not only achieve personalized match but also meet the functional requirements and aesthetic requirements of patients. In addition, the individualized medical implant has the advantages of accurate positioning, stable connection, and high strength. So 3-D printing technique has broad prospects in the manufacture and application of individualized implant.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESSES OF SINGLE-BUNDLE AND DOUBLE-BUNDLE ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BY TWO METHODS

    ObjectiveTo compare the effectiveness of single-bundle and double-bundle anterior cruciate ligament (ACL) reconstruction by two methods. MethodsQualified for the selective standard, 120 patients with ACL injury between May 2010 and April 2013 were divided into 4 groups: double-bundle reconstruction was performed by the conventional procedure in 30 cases (group A); anatomic double-bundle reconstruction was performed in the original ACL residual footprints in 30 cases (group B); single-bundle reconstruction was performed by the conventional procedure in 30 cases (group C); and anatomic single-bundle reconstruction was performed in the original ACL residual footprints in 30 cases (group D). There was no significant difference in gender, age, disease duration, pathogenesis, injury side, Lysholm scores, International Knee Documentation Committee (IKDC) ratings, Lachman test, anterior drawer test, and pivot shift test among groups (P>0.05). The impingement between the ACL implants and intercondylar notch was evaluated with postoperative immediate MRI scan and the three-dimensional digital model. Lachman test, anterior drawer test, and pivot shift test results, Lysholm scores, and IKDC ratings were used to compare the effectiveness among groups after operation. ResultsThree-dimensional digital model after operation showed impingement in 11 cases (36.7%) of group A, 1 case (3.3%) of group B, 9 cases (30.0%) of group C, and no impingement in group D. The impingement rates of groups A and C were significantly higher than that of groups B and D (P<0.05), but no significant difference was found between groups A and C, and between groups B and D (P>0.05). All incisions healed by first intention, and no early complication was found. The patients were followed up 24-30 months (mean, 26 months). Lysholm scores, Lachman test, anterior drawer test, and pivot shift test results at 24 months after operation were significantly better than preoperative ones in 4 groups (P<0.05), but no significant difference was shown among groups (P>0.05). The IKDC ratings of groups B and D were significantly better than that of groups A and C (P<0.05); but there was no significant difference between groups A and C, and between groups B and D (P>0.05). ConclusionCompared with the conventional procedure, the individual anatomic single- and double-bundle reconstruction in the original ACL residual footprints has decreased impingement rate and increased IKDC rating.

    Release date: Export PDF Favorites Scan
  • COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS

    ObjectiveTo study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. MethodsOne adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. ResultsAccording to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. ConclusionCustomized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content