west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Intramedullary" 24 results
  • External Fixation or Intramedullary Nailing For Tibial Shaft Fractures in Adults: A Systematic Review

    Objective To determine the efficacy and safety of external fixation versus intramedulllary nailing in the treatment of adult tibial shaft fracture. Methods We searched the specialized trials register of The Cochrane Collaboration’s Bone, Joint and Muscule Trauma Group, The Cochrane Library (CENTRAL), MEDLINE (1966 to March 2006), EMBASE (1980 to March 2006) and PUBMED (1966 to March 2006). We also handsearched some Chinese orthopedic journals. Randomized controlled trials (RCTs) and quasi-randomized trials (quasi-RCTs) comparing external fixation versus intramedullary nailing for tibial shaft fractures in adults were included. The quality of these trials was critically assessed. We used the Cochrane Collaboration’s RevMan 4.2.8 for data analyses. Result Three RCTs and two quasi-RCTs involving a total of 279 patients were included. The results of meta-analyses showed that external fixation for tibial shaft fractures in adults may increase the infection rate [RR 2.45, 95%CI (1.31,4.61), P=0.005], and the malunion rate [RR 2.85, 95%CI (1.20,6.79), P=0.02] but may reduce the duration of hospitalization [RR –5.50, 95%CI (–6.99,–4.01)]. The nonunion rate, delayed healing rate, and healing time, were comparable between external fixation and intramedulllary nailing. Conclusion The trials available for this systematic review are too few and small for reliable estimates of the relative effects of external fixation and intramedulllary nailing. Further studies are needed to determine these effects , especially for patients who have GustiloШ C fractures.

    Release date:2016-08-25 03:35 Export PDF Favorites Scan
  • DESIGN AND CLINICAL APPLICATION OF SURGICAL DEVICE FOR CLOSED REDUCTION OF TIBIAL FRACTURE

    Objective To describe a surgical device for closed reduction of tibial fracture and investigate its clinical effectiveness. Methods Between June 2010 and December 2012, 24 cases of tibial fractures were treated with intramedullary nailing using a surgical device for closed reduction. There were 18 males and 6 females with an average age of 40 years (range, 20-64 years). All fractures were closed. There were 3 proximal third fractures, 12 middle third fractures, and 9 distal third fractures. According to AO classification, 12 cases were classified as type A, 8 cases as type B, and 4 cases as type C. The mean time between injury and operation was 3 days (range, 1-12 days). The intraoperative fluoroscopy frequency to confirm closed reduction and guide wire passing the fracture site, and the duration between fracture reduction and nail insertion were recorded. The injured limb alignment and fracture angular deformity were measured as described by Freedman et al. The fuction of affected limb was estimated by Johner-Wruhs criteria. Results Closed reduction was successfully performed in 24 patients. The mean fluoroscopy frequency to confirm closed reduction was 3 (range, 2-5). The fluoroscopy frequency to confirm guide wire passing the fracture site was 2. The mean duration between fracture reduction and nail insertion was 30 minutes (range, 20-42 minutes). No intraoperative or postoperative complication occurred, such as infection, vessel and nerve injuries. All incisions healed by first intention. Seventeen patients were followed up 6-16 months (mean, 10 months). Radiographic evidence showed that bridging callous was observed at 2-4 months (mean, 2.5 months). The injured limb alignment was normal on anteroposterial and lateral radiographs at 5 months postoperatively, no malalignment and obvious angular deformity was observed. The internal fixator had good position. According to Johner-Wruhs criteria for evaluation of the affected limb function, the results were excellent in 12 cases and good in 5 cases with an excellent and good rate of 100%. Conclusion The surgical device for closed reduction of tibial fracture is simple and easy to use, and has good effectiveness combined with intramedullary nailing.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF DIFFERENT TIBIAL INTRAMEDULLARY NAIL GUIDE ROD IN TOTAL KNEE ARTHROPLASTY

    Objective To compare the effectiveness of the traditional center of tibial plateau as the entry point and digital technology in the design of intramedullary tibial nail point positioning method in total knee arthroplasty (TKA). Methods Between October 2011 and October 2012, 60 cases undergoing unilateral TKA and meeting the selection criteria were randomly divided into 2 groups: in group A (30 cases), the tibial plateau center as the entry point of tibial intramedullary positioning was used; in group B (30 cases), Mimics 10.01 software to simulate the guide rod point of tibial intramedullary positioning was used. There was no significant difference in gender, age, etiology, disease duration, sides, and preoperative knee range of motion, Hospital for Special Surgery (HSS) score, and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) between 2 groups (P gt; 0.05). Postoperative X-ray films were taken to measure the tibiofemoral angle and tibial angle; knee range of motion, and HSS and WOMAC scores were used to assess the activity of knee. Results The entry point of group B was located in front of the center of tibial plateau, which was inconsistent with the traditional entry point. The incision healed by first intention in all patients of 2 groups. The patients were followed up 6 to 12 months (mean, 8.6 months). The X-ray measurement at 1 week after operation showed no significant difference in tibiofemoral angle between 2 groups (t= — 6.65, P=0.72), but the anteroposterior and lateral tibial angles of group A were significantly lower than those of group B (P lt; 0.05). The knee range of motion, HSS score, and WOMAC score of 2 groups were significantly higher at 3 and 6 months after operation when compared with preoperative values (P lt; 0.05), and the values at 6 months were significantly increased than those at 3 months after operation (P lt; 0.05). HSS score and WOMAC score had no significant difference between 2 groups at 3 months after operation (P gt; 0.05), but the scores of group B were significantly higher than those of group A at 6 months (P lt; 0.05). The knee range of motion of group B was significantly better than that of group A at 3 months after operation (t=2.13, P=0.04), but no significant difference was found between 2 groups at 6 months (t=0.58, P=0.56). Conclusion Compared with the traditional intramedullary guide rod insertion point positioning, digital individualized design of entry point positioning has the advantages of more accurate lower limb force line, better recovery of knee function, and earlier 90°activities, but the long-term effectiveness needs further observation.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • COMPARISON OF TWO SURGICAL METHODS FOR ASEPTIC NONUNIONS OF FEMORAL SHAFT FRACTURES AFTER FEMORAL NAILING

    Objective To compare the outcomes between intramedullary nail change and augmentation plating with a retained intramedullary nail for aseptic nonunion of femoral shaft fractures after femoral nailing, and to analyze the cause so as to guide the clinical application. Methods Between June 2001 and June 2011, 28 patients with aseptic nonunion of femoral shaft fractures after femoral nailing were treated with intramedullary nail change (11 patients, group A) and augmentation plating with a retained intramedullary nail (17 patients, group B), and the clinical data were analyzed retrospectively. There was no significant difference in age, gender, smoking, location of fracture, Association for the Study of Internal Fixation (AO/ASIF) classification, type of injury, associated injury, type of nonunion, and time of nonunion between 2 groups (P gt; 0.05). The patients were followed up by imaging and the clinical function at regular intervals to observe the callus growth and the recovery condition of the affected limb function, and clinical curative effectiveness was evaluated by Tohner-Wrnch standard. Results The operation time, intraoperative bleeding volume, and intraoperative erythrocyte-transported volume in group A were significantly higher than those in group B (P lt; 0.05). There was no significant difference in postoperative drainage volume and hospitalization days between 2 groups (P gt; 0.05). All the incisions healed by first intention, and no nerve and blood vessel injury occurred. All patients were followed up 18.6 months on average (range, 12-36 months). All cases obtained bone union, and time of clinical and radiological bone healing in group B was significantly shorter than those in group A (P lt; 0.05). During follow-up, no following complication occurred: deep incision infection, injuries of blood vessels and nerves, loosening and breakage of internal fixation, loss of reduction, angulated and rotational malunion. According to Tohner-Wrnch standard at last follow-up, the results were excellent in 6 cases, good in 3 cases, and poor in 2 cases, with an excellent and good rate of 81.8% in group A; the results were excellent in 12 cases, good in 5 cases, with an excellent and good rate of 100% in group B; and difference was significant between 2 groups (Z= — 2.623, P=0.021). Conclusion Augmentation plating with a retained intramedullary nail is an ideal treatment for aseptic nonunion of femoral shaft fractures after femoral nailing and can achieve satisfactory clinical outcomes because it has simpler operation, shorter operation time, less blood loss, and less trauma than intramedullary nail change.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • ANTIBIOTIC-IMPREGNATED CEMENT TEMPORARY SPACER FOR SURGICAL TREATMENT OF OSTEOMYELITIS AND NONUNION OF BONE CAUSED BY INTRAMEDULLARY NAILING

    Objective To discuss the effectiveness of antibiotic-impregnated cement temporary spacer for osteomyel itis and nonunion of bone caused by intramedullary fixation. Methods Between June 2002 and May 2006, 12 patients with chronic osteomyel itis and nonunion of bone caused by intramedullary nail ing were treated, including 8 males and 4 females with an average age of 40.2 years (range, 26-53 years). The fracture locations included tibia in 7 cases and femur in 5cases. Infection occurred within 2 weeks after intramedullary fixation in 7 cases and within 3 months in 5 cases. The mean time from infection to admission was 5 months (range, 1-24 months). The results of bacteria culture were positive in 10 cases and negative in 2 cases. White blood cell (WBC) count, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were higher than normal values. An antibiotic-impregnated cement temporary spacer was inserted after removal of biomembrane and internal fixator, thorough debridement and irrigation. After osteomyel itis was controlled by antibiotic therapy postoperatively, two-stage bone transplantation and internal fixation were performed after 3 to 6 months. Results All wounds healed by first intention without early compl ication. All cases were followed up 24 to 48 months (mean, 34 months). WBC count, ESR, and CRP were normal at 3 months postoperatively. The X-ray films showed the fracture heal ing at 10-14 weeks after operation (mean, 12 weeks). Expect one patient had knee range of motion of 90°, the lower l imb function of the others returned to normal. No infection recurred during follow-up. Conclusion Antibiotic-impregnated cement temporary spacer could control osteomyelitis and nonunion of bone caused by intramedullary nail ing, and two-stage bone transplantation and internal fixation after osteomyelitis is an effictive and ideal way to treat osteomyelitis and nonunion of bone caused by intramedullary nail ing.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • BIOMECHANICAL TEST OF INTRAMEDULLARY CONTROLLED DYNAMIC NAILING

    【Abstract】 Objective To explore the biomechanical properties of a new intramedullary controlled dynamicnail ing (ICDN). Methods Ten pairs of specimens of adult femurs, with the age of 18 to 55 years, were divided into twogroups (groups A1 and B2, n=10). The length of the specimens was (438 ± 10) mm , and the external diameter was (26.4 ± 1.5) mm. The specimens of the two groups were osteotomized transversely after the biomechanical test. ICDNs and GK nails were randomly implanted into the femurs, respectively (groups A2 and B2). Torsional, bending and axial compressive tests were made in each group, and the effect of dynamic compression between the fracture fragments was tested. Results The resistance to compression of groups A1, B1, A2 and B2 were (0.19 ± 0.18) × 106, (0.22 ± 0.12) × 106, (1.67 ± 0.68) × 106 and (0.86 ± 0.32) × 106 N/mm, respectively. There was statistically significant difference between groups A2 and B2 (P lt; 0.01). The bending stiffnesses of coronal section of groups A1, B1, A2 and B2 were (0.94 ± 0.25) × 103, (1.10 ± 0.21) × 103, (0.70 ± 0.22) × 103, (0.64 ± 0.21) × 103 N/mm, respectively. The bending stiffness of sagittal plane of groups A1, B1, A2 and B2 were (1.06 ± 0.26) × 103, (0.96 ± 0.25) × 103, (0.67 ± 0.25) × 103, (0.61 ± 0.18) × 103 N/mm, respectively. There were no statistically significant differences between groups A1 and B1 or between groups A2 and B2 (P gt; 0.05). When the torque was 5 Nm, the torsional stiffness of groups A1, B1, A2 and B2 were (4.00 ± 2.54), (4.76 ± 1.93), (0.50 ± 0.63), (0.35 ± 0.31) Nm/°, respectively. When the torque was8 Nm, the torsional stiffness of groups A1, B1, A2 and B2 were (4.30 ± 3.27), (3.94 ± 2.01), (0.42 ± 0.52), (0.36 ± 0.18) Nm/°, respectively. There were statistically significant differences between groups A1 and A2 or between groups B1 and B2 (P lt; 0.05), and no statistically significant difference between between groups A2 and B2 (P gt; 0.05). The average maximal pressure generated between the fracture fragments which were fixed with ICDN was 21.6 N, and the pressure between the fracture fragments which were fixed with GK nail ing could not be tested. Conclusion The design of ICDN conforms to the special anatomical structure of the femur. ICDN could provide a completely different structure, a different fixation principal and a more balancedfixation than GK nail. ICDN incorporates the flexible and rigid fixation, which is l ikely to be the trend of the fracture fixation.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • FEMORAL SHAFT FRACTURE TREATED WITH CLOSED REDUCTION AND INTRAMEDULLARY NAILING

    【Abstract】 Objective To discuss the techniques and advantages of closed reduction and intramedullary nail ing intreating femoral shaft fracture without cannulated femoral reamer. Methods From January 2006 to June 2007, 24 cases offemoral shaft fracture were treated with closed reduction and intramedullary nail ing. Among them, there were 14 males and 10 females, with the average age of 38.3 years (ranging from 18 years to 63 years), with 7 left legs and 17 right legs. The average course of the disease was 7.6 days (ranging from 3 days to 20 days). According to the AO typing, there were 5 cases of type A, 6 of type B, 7 of type C1, 2 of type C2 and 4 of type C3. Closed reduction was achieved with manipulation and reaming of femoral canal was instructed by fluoroscopy. Results The operation time lasted from 100 minutes to 170 minutes, with the average time of 128.3 minutes. One patient was given a transfusion of 400 mL, and others were not. Twenty cases were followed up with the average time of 13.1 months (ranging from 6 months to 24 months). A mild to large amount of bony callus was showed on X-ray films 6 to 12 weeks postoperatively. Walking without crutches began at the average week of 22.2 (ranging from 15 to 30) postoperatively. Range of motion of the knee was 0° to 145.5°. No infection or break of the internal fixator occurred. Myositis ossificans with pain and insufficient flexion of hip (120°) happened in 1 case and the pain disappeared after non-steroid anti-inflammatory drugs were taken. Nonsymptomatic myositis ossificans occurred in 2 cases and no treatment was needed. Conclusion Closed reductionand intramedullary nail ing can help to protect the blood supply of fracture fragments and provide central fixation. The operation process will be more compl icated if cannulated femoral reamer is not available.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • DEVELOPMENT AND CLINICAL APPLICATION OF AN INTRAMEDULLARY CONTROLLED DYNAMIC NAI LING

    Objective To describe the design and application of a new intramedullary controlled dynamic nailing(ICDN).〓〖WTHZ〗Methods The new ICDN was made of a stainlesssteel alloy, consists of a nail shaft, innerrod, tensile screw, end cape and two interlocked screws. From December 2005 toFebruary 2007, 48 cases of femoral shaft fractures were treated with ICDN. There were 16 females and 32 males with a mean age of 36.6 years (range, 16-48years). Injury was caused by traffic accident in 26 cases, falling from a height in14, sportsrelated in 7 and crush injury in 1 case. According to Winquist classification, Thirtyseven cases were classified as typeⅠ(13 cases of typeⅠ-1,23 cases of Ⅰ-2 and 1 case of Ⅰ-3), eleven as type Ⅱ fracture ( 2 cases oftype Ⅱ-1, 8 cases of Ⅱ-2 and 1 case of Ⅱ-3). The time from injury to admission was an hour to a week. Emergency operation was performed in 19 cases and the other 29 patients were given operation within 3 days. Results All cases were followed up for an average of 5 months (3-12 months). Among them, the average healing period was 21 weeks (826 weeks) and no nonunion, delayed union and breakage of nailings occurred. The complications included 2 infections, 5 pains, and 4 deformities. Based on Johner and Wrubs standard, the results were excellent in 39 cases, good in 7 cases and fair in 2 cases, The excellent and good rate was 95.8%. Conclusions ICDN has excellent biomechanical characteristics which can provide a flexible fixation in treating femoral shaft fractures. The operation is simple and is one of the good techniquesin treating femoral shaft fractures.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Comparative Study on the Effect of Reamed and Nonreamed Intramedullary Nails on Treating Open Tibial Fractures

    Objective To compare the clinical effect of reamed and nonreamed intramedullary interlocking nails on treating open tibial fractures. Methods From February 2002 to February 2004, 92 cases of open tibial fractures (86 patients) were treated with intramedullary interlocking nails. Of the 86 patients, 65 were male and 21 were female. Their age ranged from 18 to 68 years (36.5 on average). Of the 92 cases, 54 were in the reamed group and 38 in the nonreamed group. Patients moved with the support of crutch after their wounds were healed. Results All patients were followed up regularly for 6 to 24months. Infection rate in the reamed group and nonreamed group was 20.3% and 5.3% respectively, and there was significant difference between them (Plt;0.05). The averagehealing time of the fractures was 22.5 weeks in reamed group and 19 weeks in nonreamed group, and there was no significant difference between them (P>0.05). Delayed unions occurred in 8 cases and 3 cases in reamed group and nonreamed group respectively. Conclusion Compared with reamed group, nonreamed intramedullary interlocking nails have lowerinfection rate and fewer delayed unions and ununions.

    Release date:2016-09-01 09:24 Export PDF Favorites Scan
  • CLINICAL STUDY OF PHALANGE FRACTURES TREATED BY ABSORBABLE INTRAMEDULLARY NAIL IN REPLANTATION OF SEVERED FINGER

    Objective To study the effect of internal fixation with absorbable intramedullary nail on the treatment of phalange fractures in replantation of severed finger. Methods From September 2001 to October 2003, 28 cases with industrial severed finger (21 males and 7 females, with the age of 18-35 years) were replanted within 1-6 hours. The severed locations were index fingers in 11 cases, middle fingers in 8 cases, ring fingers in 6 cases, little fingers in 3 cases. All cases of phalange fractures were fixed by absorbable intramedullary nails of poly-DL-lactic acid(PDLLA) that combined with chitosan. Out of the 28 cases, 15 cases were with proximal phalange, 11 cases were with middle phalange, 2 cases were with distal phalange. The bone marrow cavity of the phalanges were dilated, then the intramedullary nail was inserted with suitable diameter and length to fix the fracture. Postoperatively resin bandage was applied for 3-4 weeks.Results All the 28 patients survived the performance and postoperative follow-up ranged from 3 to 10 months(4 months in average). Rejection was observed in one case 3 weeks after operation, bone unions were obtained in other cases. According to the Chinese Medical Association’s evaluation standard for replantation of amputated finger, 18 fingers resulted in excellence, 9 fingers in good function and 1 with unsatisfactory function. The excellent and good rate was 96.4%. Conclusion Internal fixation with absorbable intramedullary nail of PDLLA combined with chitosan proves to be effective in the replantation of severed finger.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content