find Author "JI Zhong" 4 results
  • The research of near-infrared blood glucose measurement using particle swarm optimization and artificial neural network

    Existing near-infrared non-invasive blood glucose detection modelings mostly detect multi-spectral signals with different wavelength, which is not conducive to the popularization of non-invasive glucose meter at home and does not consider the physiological glucose dynamics of individuals. In order to solve these problems, this study presented a non-invasive blood glucose detection model combining particle swarm optimization (PSO) and artificial neural network (ANN) by using the 1 550 nm near-infrared absorbance as the independent variable and the concentration of blood glucose as the dependent variable, named as PSO-2ANN. The PSO-2ANN model was based on two sub-modules of neural networks with certain structures and arguments, and was built up after optimizing the weight coefficients of the two networks by particle swarm optimization. The results of 10 volunteers were predicted by PSO-2ANN. It was indicated that the relative error of 9 volunteers was less than 20%; 98.28% of the predictions of blood glucose by PSO-2ANN were distributed in the regions A and B of Clarke error grid, which confirmed that PSO-2ANN could offer higher prediction accuracy and better robustness by comparison with ANN. Additionally, even the physiological glucose dynamics of individuals may be different due to the influence of environment, temper, mental state and so on, PSO-2ANN can correct this difference only by adjusting one argument. The PSO-2ANN model provided us a new prospect to overcome individual differences in blood glucose prediction.

    Release date:2017-10-23 02:15 Export PDF Favorites Scan
  • Study on noninvasive blood glucose detection method using the near-infrared light based on particle swarm optimization and back propagation neural network

    Most of the existing near-infrared noninvasive blood glucose detection models focus on the relationship between near-infrared absorbance and blood glucose concentration, but do not consider the impact of human physiological state on blood glucose concentration. In order to improve the performance of prediction model, particle swarm optimization (PSO) algorithm was used to train the structure paramters of back propagation (BP) neural network. Moreover, systolic blood pressure, pulse rate, body temperature and 1 550 nm absorbance were introduced as input variables of blood glucose concentration prediction model, and BP neural network was used as prediction model. In order to solve the problem that traditional BP neural network is easy to fall into local optimization, a hybrid model based on PSO-BP was introduced in this paper. The results showed that the prediction effect of PSO-BP model was better than that of traditional BP neural network. The prediction root mean square error and correlation coefficient of ten-fold cross-validation were 0.95 mmol/L and 0.74, respectively. The Clarke error grid analysis results showed that the proportion of model prediction results falling into region A was 84.39%, and the proportion falling into region B was 15.61%, which met the clinical requirements. The model can quickly measure the blood glucose concentration of the subject, and has relatively high accuracy.

    Release date: Export PDF Favorites Scan
  • Processing of impedance cardiogram differential for non-invasive cardiac function detection

    The precise recognition of feature points of impedance cardiogram (ICG) is the precondition of calculating hemodynamic parameters based on thoracic bioimpedance. To improve the accuracy of detecting feature points of ICG signals, a new method was proposed to de-noise ICG signal based on the adaptive ensemble empirical mode decomposition and wavelet threshold firstly, and then on the basis of adaptive ensemble empirical mode decomposition, we combined difference and adaptive segmentation to detect the feature points, A, B, C and X, in ICG signal. We selected randomly 30 ICG signals in different forms from diverse cardiac patients to examine the accuracy of the proposed approach and the accuracy rate of the proposed algorithm is 99.72%. The improved accuracy rate of feature detection can help to get more accurate cardiac hemodynamic parameters on the basis of thoracic bioimpedance.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Realization of non-invasive blood glucose detector based on nonlinear auto regressive model and dual-wavelength

    The use of non-invasive blood glucose detection techniques can help diabetic patients to alleviate the pain of intrusive detection, reduce the cost of detection, and achieve real-time monitoring and effective control of blood glucose. Given the existing limitations of the minimally invasive or invasive blood glucose detection methods, such as low detection accuracy, high cost and complex operation, and the laser source's wavelength and cost, this paper, based on the non-invasive blood glucose detector developed by the research group, designs a non-invasive blood glucose detection method. It is founded on dual-wavelength near-infrared light diffuse reflection by using the 1 550 nm near-infrared light as measuring light to collect blood glucose information and the 1 310 nm near-infrared light as reference light to remove the effects of water molecules in the blood. Fourteen volunteers were recruited for in vivo experiments using the instrument to verify the effectiveness of the method. The results indicated that 90.27% of the measured values of non-invasive blood glucose were distributed in the region A of Clarke error grid and 9.73% in the region B of Clarke error grid, all meeting clinical requirements. It is also confirmed that the proposed non-invasive blood glucose detection method realizes relatively ideal measurement accuracy and stability.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan