Reconstructing three-dimensional (3D) models from two-dimensional (2D) images is necessary for preoperative planning and the customization of joint prostheses. However, the traditional statistical modeling reconstruction shows a low accuracy due to limited 3D characteristics and information loss. In this study, we proposed a new method to reconstruct the 3D models of femoral images by combining a statistical shape model with Laplacian surface deformation, which greatly improved the accuracy of the reconstruction. In this method, a Laplace operator was introduced to represent the 3D model derived from the statistical shape model. By coordinate transformations in the Laplacian system, novel skeletal features were established and the model was accurately aligned with its 2D image. Finally, 50 femoral models were utilized to verify the effectiveness of this method. The results indicated that the precision of the method was improved by 16.8%–25.9% compared with the traditional statistical shape model reconstruction. Therefore, the method we proposed allows a more accurate 3D bone reconstruction, which facilitates the development of personalized prosthesis design, precise positioning, and quick biomechanical analysis.
The geometric bone model of patients is an important basis for individualized biomechanical modeling and analysis, formulation of surgical planning, design of surgical guide plate, and customization of artificial joint. In this study, a rapid three-dimensional (3D) reconstruction method based on statistical shape model was proposed for femur. Combined with the patient plain X-ray film data, rapid 3D modeling of individualized patient femur geometry was realized. The average error of 3D reconstruction was 1.597–1.842 mm, and the root mean square error was 1.453–2.341 mm. The average errors of femoral head diameter, cervical shaft angle, offset distance and anteversion angle of the reconstructed model were 0.597 mm, 1.163°, 1.389 mm and 1.354°, respectively. Compared with traditional modeling methods, the new method could achieve rapid 3D reconstruction of femur more accurately in a shorter time. This paper provides a new technology for rapid 3D modeling of bone geometry, which is helpful to promote rapid biomechanical analysis for patients, and provides a new idea for the selection of orthopedic implants and the rapid research and development of customized implants.
A micro silicone oil liquid spring was designed and manufactured in this article. The performance of the liquid spring was studied by simulation analysis and mechanical test. A self-force source power-assisted knee orthosis was designed based on the liquid spring. This power-assisted knee orthosis can convert the kinetic energy of knee flexion into the elastic potential energy of liquid spring for storage, and release elastic potential energy to generate assisted torque which drives the knee joint for extension. The results showed that the average maximum reset force of the liquid spring was 1 240 N, and the average maximum assisted torque for the knee joint was 29.8 N·m. A musculoskeletal multibody dynamic model was used to analyze the biomechanical effect of the knee orthosis on the joint during knee bending (90°knee flexion). The results showed that the power-assisted knee orthosis could effectively reduce the biomechanical load of the knee joint for the user with a body weight of 80 kg. The maximum forces of the femoral-tibial joint force, patellar-femoral joint force, and quadriceps-ligament force were reduced by 24.5%, 23.8%, and 21.2%, respectively. The power-assisted knee orthosis designed in this article provides sufficient assisted torque for the knee joint. It lays a foundation for the subsequent commercial application due to its small size and lightweight.
Posterior-stabilized total knee prostheses have been widely used in orthopedic clinical treatment of knee osteoarthritis, but the patients and surgeons are still troubled by the complications, for example severe wear and fracture of the post, as well as prosthetic loosening. Understanding the in vivo biomechanics of knee prostheses will aid in the decrease of postoperative prosthetic revision and patient dissatisfaction. Therefore, six different designs of posterior-stabilized total knee prostheses were used to establish the musculoskeletal multibody dynamics models of total knee arthroplasty respectively, and the biomechanical differences of six posterior-stabilized total knee prostheses were investigated under three simulated physiological activities: walking, right turn and squatting. The results showed that the post contact forces of PFC Sigma and Scorpio NGR prostheses were larger during walking, turning right, and squatting, which may increase the risk of the fracture and wear as well as the early loosening. The post design of Gemini SL prosthesis was more conductive to the knee internal-external rotation and avoided the edge contact and wear. The lower conformity design in sagittal plane and the later post-cam engagement resulted in the larger anterior-posterior translation. This study provides a theoretical support for guiding surgeon selection, improving posterior-stabilized prosthetic design and reducing the prosthetic failure.
The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients’ walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427−0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.
The use of a filling block can improve the initial stability of the fixation plate in the open wedge high tibial osteotomy (OWHTO), and promote bone healing. However, the biomechanical effects of filling block structures and materials on OWHTO remain unclear. OWHTO anatomical filling block model was designed and built. The finite element analysis method was adopted to study the influence of six filling block structure designs and four different materials on the stress of the fixed plate, tibia, screw, and filling block, and the micro-displacement at the wedge gap of the OWHTO fixation system. After the filling block was introduced in the OWHTO, the maximum von Mises stress of the fixation plate was reduced by more than 30%, the maximum von Mises stress of the tibia decreased by more than 15%, and the lateral hinge decreased by 81%. When the filling block was designed to be filled in the posterior position of the wedge gap, the maximum von Mises stress of the fixation system was 97.8 MPa, which was smaller than other filling methods. The minimum micro-displacement of osteotomy space was –2.9 μm, which was larger than that of other filling methods. Compared with titanium alloy and tantalum metal materials, porous hydroxyapatite material could obtain larger micro-displacement in the osteotomy cavity, which is conducive to stimulating bone healing. The results demonstrate that OWHTO with a filling block can better balance the stress distribution of the fixation system, and a better fixation effect can be obtained by using a filling block filled in the posterior position. Porous HA used as the material of the filling block can obtain a better bone healing effect.
Aiming at comparing the pre-operative and post-operative gait characteristics and therefore establishing post-operative rehabilitation guidance for patients with end-stage knee osteoarthritis (KOA) merged with varus deformity, this study captured the level walking and sit-to-stand trials of 9 patients with 3-dimensional motion analysis system and after which musculoskeletal multi-body dynamic analysis was conducted. The study indicated that the average range of motion (ROM) of the proposed-surgical knee was 24.4°–57.6° and that of the non-surgical knee was 22.5°–71.5°. The knee ROM of control group during level walking was 7.2°–62.4°. When the unilateral KOA patients stood up from chair to complete the sit-to-stand movement, the ground reaction forces (GRFs) symmetry was 0.72–0.85, which means that the non-surgical limb bear the majority of body weight. The GRFs of the bilateral KOA patients were smallest during the sit-to-stand movement. The strategy that the non-surgical limb dominates in loading bearing taken by the unilateral KOA patients to cover most post-operative daily activities could increase the risk of KOA among non-surgical side joints as a result of long-term excessive loading-bearing. The study, on kinematics and biomechanical characteristics of patients with KOA merged with varus deformity, could help to understand the pathogenesis of KOA merged with varus deformity from the perspective of biomechanics and to provide strong clinic guidance for the pre-operative evaluation, prevention and post-operative recovery for patients.
To investigate the biomechanical effects of direct ventricular assistance and explore the optimal loading mode, this study established a left ventricular model of heart failure patients based on the finite element method. It proposed a loading mode that maintains peak pressure compression, and compared it with the traditional sinusoidal loading mode from both hemodynamic and biomechanical perspectives. The results showed that both modes significantly improved hemodynamic parameters, with ejection fraction increased from a baseline of 29.33% to 37.32% and 37.77%, respectively, while peak pressure, stroke volume, and stroke work parameters also increased. Additionally, both modes showed improvements in stress concentration and excessive fiber strain. Moreover, considering the phase error of the assist device's working cycle, the proposed assist mode in this study was less affected. Therefore, this research may provide theoretical support for the design and optimization of direct ventricular assist devices.