find Keyword "Ken-Valve prosthesis" 1 results
  • Transapical transcatheter aortic valve replacement using Ken-Valve for severe aortic stenosis combined with severe aortic regurgitation: A case report

    Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. The use of new heart valves prosthesis has improved surgical safety and efficacy. This report described a 72-year-old male patient with severe aortic stenosis combined with severe aortic regurgitation, who was evaluated at moderate-high risk of surgery and received a transapical TAVR using the Ken-Valve heart valve. The transcatheter operation time was 8 min, and the blood loss was 50 mL. The tracheal intubation was removed immediately after the surgery. Transesophageal echocardiography on the 4th postoperative day showed that the aortic valve leaflets worked well, and there was no valve orifice and paravalvular leakage. The patient was discharged on the 5th day after the surgery without complications. Transapical TAVR using Ken-Valve was an easy surgical procedure for aortic valve disease, and had short operation time.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next