Objective To evaluate the short-term effectiveness after static anatomical reconstruction of posterolateral complex (PLC) in the treatment of traumatic multi-ligament injury of the knee. Methods Between June 2007 and July 2011, 23 cases of multi-ligament injury of the knee were treated. There were 15 males and 8 females with an average age of 41 years (range, 19-56 years). The injury was caused by traffic accident in 9 cases, sprain in 7 cases, bruise in 3 cases, and falling from height in 4 cases. The time between injury and operation was 13-78 days (mean, 32 days). The results of posterior drawer test and Lachman test were positive, and all cases complicated by varus and external rotation instability. The Lysholm score of the knee was 43.4 ± 5.7. According to International Knee Documentation Committee (IKDC) scoring, all were rated as grade D. According to Fanelli typing, all were classified as type C. The X-ray films showed that load-induced posterior motion of the knee was (13.3 ± 4.2) mm; the lateral joint space was (15.1 ± 2.4) mm. Anterior cruciate ligament/posterior cruciate ligament and PLC were reconstructed simultaneously with auto-semitendinosus, gracilis tendon, and allogeneic tendon. Results All incisions healed by first intention, and no complication occurred. All patients were followed up 12-56 months (mean, 28 months). At last follow-up, the results of posterior drawer test and Lachman test were negative; 3 cases had varus instability, and 2 cases had external rotation instability. The Lysholm score of the knee was 85.6 ± 16.7, showing significant difference when compared with preoperative score (t=11.469, P=0.000). According to IKDC scoring, 7 cases were rated as grade A, 12 as grade B, and 4 as grade C; significant difference was found when compared with preoperative value (Z=4.285, P=0.000). The load-induced posterior motion of the knee was (5.1 ± 4.4) mm, the lateral joint space was (3.2 ± 2.8) mm, showing significant differences when compared with preoperative ones (P lt; 0.05). Conclusion In the treatment of traumatic multi-ligament injury of the knee, the anatomical reconstruction of the PLC using auto-semitendinosus, gracilis tendon, or allogeneic tendon can obtain good short-term effectiveness.
Objective To summarize the anatomic features of the posterior septum of the knee joint and its application in posterior trans-septal portal for arthroscopic surgery. Methods The literature related to posterior septum of the knee joint and arthroscopic surgery was extensively reviewed and analyzed. Results The posterior septum of the knee joint has more mechanoreceptors and blood vessels in the upper part, which are close to arteria popliteal at the tibial plateau level; the posterior compartment is divided into wider posteromedial and narrower posterolateral compartments. A safe arthroscopic trans-septal portal is established, in the knee flexion of 90°, in a lateral-to-medial direction, and with an inserting location below the middle of posterior septum. Conclusion The establishment method of posterior trans-septal portal is not uniform and all the features of posterior septum should be considered to decrease the complications.
Objective To investigate the feasibility of the preservation of the epiphysis and joint function of the distal femur in children with osteosarcoma with epiphyseal distraction by external fixator. Methods Between July 2007 and May 2011, 6 children with osteoblastic osteosarcoma of the distal femur underwent epiphyseal distraction by external fixator, combined with tumor resection and repair with massive allograft bone transplantation to preserve the epiphysis and joint function of the distal femur. There were 4 boys and 2 girls, aged from 9 to 14 years (mean, 10.5 years). According to Enneking clinical staging, 4 cases were in stage II A and 2 cases in stage II B. According to San-Julian et al. typing for metaphyseal tumor invasion, 3 cases were in type I and 3 cases in type II. The size of tumor ranged from 6 cm × 4 cm to 12 cm × 9 cm. All patients received 2 cycles of COSS 86 chemotherapy before operation and 4 cycles after operation. Results Poor healing of incision was observed in 1 case because of rejection of allograft bone and good healing was obtained after the symptomatic treatment, healing of incision by first intention was achieved in the other children. All 6 cases were followed up 11 to 56 months (mean, 37.5 months). One case died of lung metastasis at 2 years after operation. X-ray films showed no complication of internal fixator loosening and broken or bone nonunion. According to the functional evaluation criteria of International Society of Limb Salvage (ISOLS) at last follow-up, the results were excellent in 3 cases, good in 2 cases, and fair in 1 case; the excellent and good rate was 83.3%. The length of operated limb was (62.97 ± 7.51) cm, showing significant difference when compared with that of normal limb [(64.03 ± 7.47) cm] (t=0.246 6, P=0.813 4). Conclusion On the premise of adaptable indication, effective chemotherapy, and thoroughly tumor resection, the epiphyseal distraction by external fixator can obtain satisfactory results in limb-length and limb function in children with osteoblastic osteosarcoma of the distal femur.
【Abstract】 Objective When knee medial collateral ligament (MCL) rupture, the upper surface of medial meniscus is exposed totally, like the gulf panoramic, which is called “panoramic views of the bay sign” or the “bay sign”. To investigate the reliability and significance of the “bay sign” in diagnosis of knee MCL rupture under arthroscope. Methods Between March 2007 and March 2011, 127 patients with knees injuries were divided into the observation group (n=59) and control group (n=68) based on the MRI results. In the observation group, 59 patients had MCL rupture by MRI, including 12 cases of MCL injury alone, 16 cases of MCL injury with lateral meniscus torn, 27 cases of MCL injury with anterior cruciate ligament (ACL) injury, 3 cases of MCL injury with ACL and posterior cruciate ligament (PCL) injury, and 1 case of MCL injury with patellar dislocation; there were 38 males and 21 females with an average age of 23.2 years (range, 16-39 years). In the control group, 68 patients had no MCL rupture by MRI, including 38 cases of ACL injury, 4 cases of ACL and PCL injury, and 26 cases of ACL and lateral meniscus injury; there were 45 males and 23 females with an average age of 31.8 years (range, 25-49 years). The “bay sign” was observed under arthroscope in 2 groups before and after operation. Results The positive “bay sign” was seen under arthroscope in the patients of the observation group before MCL repair; the “bay sign” disappeared after repair. No “bay sign” was seen in patients of the control group before and after ACL reconstruction. Conclusion The “bay sign” is a reliable diagnostic evidence of MCL injury. It can be used as a basis to judge the success of MCL reconstruction during operation.
Objective To establish the three-dimensional (3D) finite element model of the knee joint including posterolateral complex (PLC), and to simulate the reconstruction biomechanical analysis in this model. Methods The knee of a 26-year-old healthy man was scanned by MRI to obtain the image data of the knee in the coronal, sagittal, and axial position. First, Mimics10.01 and Hyperworks 8.0 softwares were used to extract each slice profile data of the knee joint in a two-dimensional image data respectively and to establish 3D geometric model of bone, meniscus, articular cartilage, and ligament. Second, Unigraphics software NX 4.0 was used to establish a 3D finite element model of knee joint, which had the functions of Mesh, material properties, component connection, and contact definition. Third, displacement measurement on the model and reconstructing biomechanical analysis for PLC simulation were performed. Results The 3D finite element model of the knee joint including PLC was established successfully. Under 134 N forward force, the tibia forward displacement was 4.83 mm. PLC simulation reconstruction biomechanical analysis of the 3D finite element model of the knee joint showed that under 10 N·m varus and external rotation torque conditions, the knee varus and external rotation angles of simulation reconstruction were greater than those of the intact knee, and less than those of PLC missing. Conclusion The 3D finite element model of the knee joint including PLC can be established by the reverse engineering, and it is valid and can be used as the basis for the biomechanical properties to analog reconstruction of PLC.
Objective To investigate the effectiveness of anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) reconstruction combined with l imited open repair of medial collateral ligament (MCL) in recovering the stabil ity and the function of the knee. Methods Between April 2003 and October 2010, 14 patients (14 knees) with multi ple injuries of ACL, PCL, and MCL were treated. There were 10 males and 4 females with an average age of 41 years (range, 21- 71 years). Injury was caused by traffic accident in 11 cases and fall ing in 3 cases. The average time from injury to admissionwas 2 days (range, 1-4 days). Lysholm score was 17.00 ± 8.29, and the International Knee Documentation Committee (IKDC) score was 20.93 ± 8.28. The complicated injuries included dislocation of the knee joint in 9 cases and meniscus injury in 5 cases. Allogeneic tendons (2 cases) and autologous harmstring tendon (12 cases) were used to reconstruct ACL and PCL under arthroscopy, and all cases underwent limited open repair of MCL. Results All incisions healed by first intention. Numbness of the lower limb occurred in 3 cases and alleviated spontaneously. All patients were followed up 14 months on average (range, 12-18 months). The knee flexion was 120° and extension was 0° at 3 months of follow-up. After 1 year of follow-up, IKDC score and Lysholm score were 89.93 ± 6.26 and 88.93 ± 4.82, respectively, showing significant differences when compared with preoperative scores (P lt; 0.01). Conclusion For multi ple injuries of the knee ligaments, an arthroscope with limited open repair and reconstruction of the knee ligament can avoid open joint chamber, reduce postoperative articular adhesion, and encourage the joint function recovery.
Objective To investigate the role of β-catenin in pathogenesis and progression of knee primaryosteoarthritis (OA) by detecting the expression of β-catenin. Methods Between October 2010 and May 2011, 40 cartilagespecimens were collected from adult knee primary OA patients undergoing total knee arthroplasty and 10 cartilage specimensfrom adult patients suffering from amputation and femoral condylar fracture. All cartilage samples were taken out from femoralcondylar. The decalcified paraffin-embedded sections were prepared and stained with fast green-safranin O to observe thedegeneration of cartilage, then the modified Mankin scale was used to classify the degeneration. The expression of β-cateninwas detected by the immunohistochemistry staining and Western blot. Results According to the Mankin scale, 10 caseshad normal cartilage, 12 had mild degenerative cartilage, and 28 had moderate to severe degenerative cartilage. The histologicalobservation showed the mild degenerative cartilage characterized by fissures in the superficial zone of the articular cartilage,decreased chondrocytes, arrangement disorder, and duplicated tidemark; and the moderate to severe degenerative cartilagecharacterized by fissures in the deep zone of the articular cartilage, obviously decreased chondrocytes and cluster, and even fullthicknesscartilage defect. The β-catenin did not expressed in normal articular cartilage; but it expressed in the degenerativecartilage, and the expression was significantly higher in the moderate to severe degenerative cartilage than in mild degenerativecartilage (P lt; 0.05). Conclusion β-catenin plays a significant role in the pathogenesis and progression of knee primary OA,and the mechanism may be the activation of Wnt/β-catenin signaling pathway, which promotes transcri ption of inflammatorygenes and leads to the destruction of articular cartilage.
Objective To discuss the effectiveness of operation technique for antero-medial rotatory instability (AMRI) of the knee joint caused by motorcycle. Methods Between June 2007 and December 2009, 32 cases of AMRI caused by motorcycle were treated. There were 28 males and 4 females with an average age of 35.5 years (range, 20-50 years). The interval between injury and surgery was 5-10 days (mean, 7 days). The anterior cruciate ligament (ACL) was injured at the attachment point of the condyles crest; the medial collateral ligament (MCL) was injured at central site in 19 cases, at medial condyles of femur in 10 cases, and at medial condyles of tibia in 3 cases, which were all closed injuries. The bone avulsion of condyles crest was fixed by steel wire and MCL was repaired. Results Red swelling and a little effusion occurred at the incision in 1 case, and the other incisions healed by first intention. Traumatic arthritis of the knee occured in 5 cases. Thirty-two cases were followed up 16-22 months (mean, 18.5 months). The X-ray examination showed that the fracture union time was 5-8 weeks (mean, 6 weeks) after operation. At last follow-up, the extension of knee joint was 0° and the flexion of the knee joint was 110-170° (mean, 155°). According to the synthetic evaluating standard of International Knee Documentation Committee, 24 cases were rated as A level, 6 cases as B, 1 case as C, and 1 case as D at last follow-up. Lysholm knee score was 85.93 ± 3.76 at last follow-up, which was significantly higher (t=53.785, P=0.000) than preoperative score 37.54 ± 3.43. Conclusion In patients with AMRI caused by motorcycle, steel wire is used to fix the bone avulsion of condyles crest and MCL should be repaired simultaneously as far as possible. And associating with the early postoperative functional exercise, the short-term effectiveness is satisfactory, but long-term effectiveness still need further follow-up observation.
Objective To discuss the authenticity of reconstructing the anterior cruciate l igament (ACL) threedimensional digital model of normal adult knee joint by use of MRI. Methods The double knee joint specimens were selected from 20 fresh normal adult corpses and double knee joint of 20 normal adult volunteers, and were scanned with MRI; continuous image data of level thick 1.0 mm were acquired, and then these data were imported into Mimics 10.01 software for three-dimensional reconstruction; and full three-dimensional digital models were built, including the corpse specimens (corpsemodel group) and normal adult (normal model group). The relevance anatomy index of ACL were measured with easuring tool of Mimics 10.01 software, and double knee joint specimens of 20 fresh normal adult corpses were dissected, and the relevance data were measured (corpse specimens group). Results There was no significant difference in all indexes between corpse model group and corpse specimen group (P gt; 0.05), and between corpse model group and normal model group (P gt; 0.05). Conclusion The image data gathered by MRI could reconstruct the ACL three-dimensional digital model of normal adult knee joint, which has authenticity.
Objective To evaluate the feasibility of the anterior cruciate ligament (ACL) reconstruction with 6 strands of hamstring tendons enveloped by periosteum. Methods Between April 2008 and April 2009, 34 patients with ACL injury were treated, ACL of whom was reconstructed with 6 strands of hamstring tendons enveloping of periosteum and double Rigidfix fixation. There were 30 males and 4 females, aged 19-54 years with an average of 29.4 years. The causes of injury included sport in 19 cases, traffic accident in 8 cases, falling from height in 5 cases, and other in 2 cases. The locations were left knee in 19 cases and right knee in 15 cases. The disease duration was 3 weeks to 18 months (median, 9.4 months). The results of Lachman test and anterior drawer test were positive. The Lysholm knee score was 61.5 ± 3.6. MRI examination revealed ACL rupture in 26 cases and ACL injury in 8 cases. Results All incisions healed by first intention, and no early complication occurred. Twenty-eight cases were followed up 12-32 months (mean, 16.1 months). The result of Lachman test was negative at 12 months after operation; in all patients, knee extension reached 0°, and flexion reached 120-150° (mean, 132.5°). The AP and lateral X-ray films and MRI showed no bone tunnel expansion. At last follow-up the therapeutic effect evaluation was excellent in 25 cases, good in 1 case, and fair in 2 cases; the excellent and good rate was 92.9%. The postoperative Lysholm score was 91.0 ± 3.2, showing significant difference when compared with preoperative score (t=32.78, P=0.00). Conclusion Six strands of hamstring tendons can ensure sufficient tensile strength, and use of the double Rigidfix absorbable screw makes fixation more reliable. Facing outside suture of periosteal flap can promote tendon-bone healing, so it is a good method of ACL reconstruction.