west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LÜ Chunliu" 16 results
  • Application and prospect of preoperative computed tomographic angiography in deep inferior epigastric artery perforator flap for breast reconstruction

    ObjectiveTo generalize the application and prospect of computed tomographic angiography (CTA) in deep inferior epigastric artery perforator (DIEP) flap transfer for breast reconstruction.MethodsThe related literature using CTA for DIEP flap reconstruction of breast in recent years was reviewed and analyzed.ResultsPreoperative CTA can accurately assess the vascular anatomy of the chest and abdomen wall, precisely locating the perforator in the abdominal donor site, and identifying the dominant perforator; guide the selection of intercostal space to explore internal mammary artery and internal mammary artery perforator in the chest recipient vessels. It can also reconstruct the volume of the abdominal flap with reference to the size of the contralateral breast and pre-shape the abdominal flap, which are crucial to formulate the surgical plan and improve the reliability of flap.ConclusionPreoperative CTA has enormous application potential and prospects in locating donor area perforator, in selecting recipient vessels, and in evaluating breast volume for autologous breast reconstruction with DIEP flap.

    Release date:2020-07-27 07:36 Export PDF Favorites Scan
  • Application of pedicled anterolateral thigh myocutaneous flap for full-thickness abdominal wall reconstruction after tumor resection

    ObjectiveTo explore the effectiveness of pedicled anterolateral thigh myocutaneous flap for full-thickness abdominal wall reconstruction after tumor resection.MethodsBetween September 2010 and December 2017, 18 patients with abdominal wall tumors were collected. There were 11 males and 7 females, with an average age of 45.2 years (range, 29-68 years). Histologic diagnosis included desmoid tumor in 8 cases, sarcomas in 6 cases, malignant teratoma in 2 cases, and colon adenocarcinoma in 2 cases. All abdominal wall defects were full-thickness defects. Peritoneum continuity was reconstructed with mesh; the lateral vastus muscular flaps were used to fill the dead space and rebuild the abdominal wall strength; the abdominal wall soft tissue defects were repaired with pedicled anterolateral thigh flaps. The size of abdominal wall defects ranged from 15 cm×6 cm to 25 cm×22 cm; the size of lateral vastus muscular flap ranged from 10 cm×8 cm to 22 cm×10 cm; the size of anterolateral thigh flap ranged from 14.0 cm×8.0 cm to 21.0 cm×8.5 cm. The bilateral pedicled anterolateral thigh myocutaneous flaps were harvested to repair the extensive abdominal wall defects in 2 cases. All donor sites were sutured directly.ResultsAll wounds healed smoothly and all flaps survived totally. All donor sites healed smoothly. The mean follow-up time was 22.5 months (range, 11-56 months). No tumor recurrence occurred, the abdominal function and appearance were satisfactory, no abdominal hernia was noted. Only linear scar left at the donor sites.ConclusionPedicled anterolateral thigh myocutaneous flap combined with mesh is fit for large full-thickness abdominal defect reconstruction.

    Release date:2019-06-04 02:16 Export PDF Favorites Scan
  • Modified pedicled anterolateral thigh myocutaneous flap for large full-thickness abdominal defect reconstruction

    Objective To investigate the reconstructive methods and effectiveness of modified pedicled anterolateral thigh (ALT) myocutaneous flap for large full-thickness abdominal defect reconstruction. Methods Between January 2016 and June 2018, 5 patients of large full-thickness abdominal defects were reconstructed with modified pedicled ALT myocutaneous flaps. There were 3 males and 2 females with an average age of 43.7 years (range, 32-65 years). Histologic diagnosis included desmoid tumor in 3 cases and sarcoma in 2 cases. The size of abdominal wall defect ranged from 20 cm×12 cm to 23 cm×16 cm. Peritoneum continuity was reconstructed with mesh; lateral vastus muscular flap was used to fill the dead space and rebuild the abdominal wall strength; skin grafting was applied on the muscular flap, the rest abdominal wall soft tissue defects were repaired with pedicled ALT flap. The size of lateral vastus muscular flap ranged from 20 cm×12 cm to 23 cm×16 cm, the size of ALT flap ranged from 20 cm×8 cm to 23 cm×10 cm. The donor site was closed directly. Results All flaps and skin grafts survived totally, and incisions healed by first intention. All patients were followed up 6-36 months (mean, 14.7 months). No tumor recurrence occurred, and abdominal function and appearance were satisfying. No abdominal hernia was noted. Only linear scar left in the donor sites, and the function and appearance were satisfying. Conclusion Modified pedicled ALT myocutaneous flap is efficient for large full-thickness abdominal defect reconstruction, decrease the donor site morbidity, and improve the donor site and recipient site appearance.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Application of modified designed bilobed latissimus dorsi myocutaneous flap in chest wall reconstruction of locally advanced breast cancer patients

    ObjectiveTo explore the effectiveness of the modified designed bilobed latissimus dorsi myocutaneous flap in chest wall reconstruction of locally advanced breast cancer (LABC) patients.MethodsBetween January 2016 and June 2019, 64 unilateral LABC patients were admitted. All patients were female with an average age of 41.3 years (range, 34-50 years). The disease duration ranged from 6 to 32 months (mean, 12.3 months). The diameter of primary tumor ranged from 4.8 to 14.2 cm (mean, 8.59 cm). The size of chest wall defect ranged from 16 cm×15 cm to 20 cm×20 cm after modified radical mastectomy/radical mastectomy. All defects were reconstructed with the modified designed bilobed latissimus dorsi myocutaneous flaps, including 34 cases with antegrade method and 30 cases with retrograde method. The size of skin paddle ranged from 13 cm×5 cm to 17 cm×6 cm. All the donor sites were closed directly.ResultsIn antegrade group, 2 flaps (5.8%, 2/34) showed partial necrosis; in retrograde group, 6 flaps (20%, 6/30) showed partial necrosis, 5 donor sites (16.7%, 5/30) showed partial necrosis; and all of them healed after dressing treatment. The other flaps survived successfully and incisions in donor sites healed by first intention. There was no significant difference in the incidence of partial necrosis between antegrade and retrograde groups (χ2=2.904, P=0.091). The difference in delayed healing rate of donor site between the two groups was significant (P=0.013). The patients were followed up 15-30 months, with an average of 23.1 months. The appearance and texture of the flaps were satisfactory, and only linear scar left in the donor site. No local recurrence was found in all patients. Four patients died of distant metastasis, including 2 cases of liver metastasis, 1 case of brain metastasis, and 1 case of lung metastasis. The average survival time was 22.6 months (range, 20-28 months).ConclusionThe modified designed bilobed latissimus dorsi myocutaneous flap can repair chest wall defect after LABC surgery. Antegrade design of the flap can ensure the blood supply of the flap and reduce the tension of the donor site, decrease the incidence of complications.

    Release date: Export PDF Favorites Scan
  • Clinical application of relaying anteromedial thigh perforator flap in resurfacing of donor defect after anterolateral thigh flap transfer

    Objective To investigate the clinical application of relaying anteromedial thigh (AMT) perforator flap in resurfacing of the donor defect after anterolateral thigh (ALT) flap transfer. Methods Between February 2012 and December 2015, 23 cases of oral carcinoma underwent radical resection; after resection of lesions, the tongue or mouth floor defects were reconstructed by ALT perforator flaps, and the donor sites were repaired with relaying AMT perforator flap at the same stage. There were 21 males and 2 females,with a mean age of 52.6 years (range, 29-74 years). Sixteen patients had tongue squamous cell carcinoma and 7 patients had buccal cancer. According to TNM tumor stage, 3 cases were classified as T4N0M0, 5 cases as T4N1M0, 7 cases as T3N1M0, 5 cases as T3N2M0, and 3 cases as T3N0M0. The disease duration ranged from 6 to 18 months (mean, 8.8 months). Results The AMT perforators existed consistently in all patients. All flaps survived, and primary healing of wounds was obtained at recipient sites and donor sites. No vascular crisis, wound dehiscence, or obvious swelling occurred. All patients were followed up 6-20 months (mean, 9.4 months). There was only linear scar at the donor sites, and the function of thighs was normal. The color and contour of the flaps were satisfactory. Conclusion The relaying AMT perforator flap is an ideal choice to reconstruct the donor site of ALT flap.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • Application of indocyanine green-based fluorescent angiography in autologous tissue breast reconstruction

    ObjectiveTo investigate the effect of indocyanine green (ICG)-based fluorescent angiography in autologous tissue breast reconstruction.MethodsBetween June 2016 and June 2017, 14 female patients were treated with the autologous tissue breast reconstruction. The age ranged from 27 to 64 years with the median age of 46.5 years. There were 11 patients of one-stage reconstruction, including 9 with invasive ductal carcinoma of breast, 1 with recurrence tumor on chest wall, and 1 with angiosatcoma in the breast. The disease duration ranged from 9 days to 48 months (mean, 6.8 months). There were 3 patients of second-stage breast reconstruction, who underwent mastectomy 3-4 years ago. During operation, the first ICG-based fluorescent angiography was done before cutting off the flap pedicle. According to the results, 13 patients were adjusted the strategy of operation or cut part of flap, only 1 patient kept the original design. Then, the infusion of flaps were confirmed by the second ICG-based fluorescent angiography after transplanted to the recipient site. The area of flap ranged from 24 cm×11 cm to 36 cm×15 cm. All incisions of recipient site were closed by primary suture.ResultsThe fat liquefaction of incision occurred in 1 patient with type 2 diabetes, and the incision healed after debridement operation. The other flaps survived with no flap perfusion related complication. Both donor sites and recipient sites healed by first intention. All patients were followed up 1-14 months (mean, 4 months) with satisfied result of reconstruction. There was no tumor recurrence.ConclusionICG-based fluorescent angiography can reveal the perfusion of the flap in operation instantly and accurately. It should be very helpful to adjusting the strategy in reconstructive operation, especially in the large tissue demanded kinds such as breast reconstruction.

    Release date:2018-04-03 09:11 Export PDF Favorites Scan
  • Effectiveness of bipaddled anterolateral thigh perforator flap in repair of through-and-through maxillofacial defect after oral cancer ablation

    ObjectiveTo investigate the effectiveness of bipaddled anterolateral thigh perforator flap in repair of through-and-through maxillofacial defect following oral cancer ablation.MethodsBetween January 2008 and December 2016, 42 patients with oral cancer were treated. There were 31 males and 11 females with an average age of 44.5 years (range, 31-68 years). There were 28 cases of buccal mucosa carcinoma, 10 cases of basal cell carcinoma of buccal skin, 3 cases of gingiva carcinoma, and 1 case of recurrent parotidduct carcinoma. The disease duration ranged from 1 to 24 months (mean, 13.5 months). The size of through-and-through maxillofacial defect ranged from 6.0 cm×4.5 cm to 9.0 cm×7.0 cm. All defects were repaired with the bipaddled anterolateral thigh perforator flap. The paddles were adjusted to repair the buccal area. And the size of flap ranged from 7 cm×5 cm to 10 cm×8 cm. The donor sites were closed directly.ResultsThe operation time was 4.5-7.5 hours (mean, 5.5 hours). All flaps healed and the wounds of recipient and donor sites healed by first intention. All patients were followed up 9-60 months (mean, 22 months). All patients were satisfied with their facial appearance and the speech function. The range of mouth opening was 3-5 cm. Three patients died of recurrence during the follow-up period and the other patients were alive.ConclusionThe bipaddled anterolateral thigh perforator flap is flexible and reliable for the through-and-through maxillofacial defect reconstruction following oral cancer ablation.

    Release date:2018-05-02 02:41 Export PDF Favorites Scan
  • Application of combined transverse upper gracilis flap and adductor magnus perforator flap in breast reconstruction

    ObjectiveTo explore the clinical application of combined transverse upper gracilis flap and adductor magnus perforator flap in breast reconstruction of breast cancer patients after mastectomy.MethodsBetween August 2016 and February 2017, the combined transverse upper gracilis flap and adductor magnus perforator flap was used in 12 cases of breast cancer patients who received modified radical surgery for breast reconstruction. All patients were females with the age of 32 to 59 years (mean, 41.5 years). There were 7 cases in left side and 5 cases in right side. Eight cases were received breast reconstruction by one-stage operation and 4 cases by two-stage operation. In one-stage operation cases, pathological diagnosis includes invasive ductal carcinoma in 4 cases and invasive lobular carcinoma in 4 cases. The disease duration ranged from 2 to 9 months (mean, 4.5 months). In two-stage operation cases, the time interval between mastectomy and breast reconstruction ranged from 12 to 70 months (mean, 37.4 months). The length of flap was 20-28 cm, the width of flap was 5.5-7.5 cm, the thickness of flap was 2.5-4.5 cm. The length of gracilis flap pedicle was 6.5-9.2 cm, the length of adductor magnus perforator flap pedicle was 7.5-10.4 cm. The weight of flap was 295-615 g.ResultsThe ischemia time of flap ranged from 95 to 230 minutes (mean, 135 minutes). All flaps were successfully survived. All incisions of recipient donor sites healed by first intention. All patients were followed up 7-14 months (mean, 9.5 months). The reconstructed breasts’ shape, texture, and elasticity were good and no flap contracture deformation happened. Only linear scar left in the donor sites, but the function of thighs was not affected. No local recurrence happened during follow-up.ConclusionWith appropriate patient selection and surgical technique, the combined transverse upper gracilis flap and adductor magnus perforator flap can be a valuable option as an alternative method for autologous breast reconstruction.

    Release date:2018-05-30 04:28 Export PDF Favorites Scan
  • Application progress of indocyanine green angiography in breast reconstruction

    Objective To summarize the application progress of indocyanine green (ICG) angiography in breast reconstruction. Methods The literature about the application of ICG angiography in breast reconstruction was reviewed and analyzed, including its history, chemical composition, principles, usages, and attentions. Results ICG is a kind of fluorescent substance used in medical diagnosis and various surgical fields, especially in intraoperative vascular angiography. ICG angiography and SPY system are gradually applied in breast reconstruction, including both prosthesis/tissue expander reconstruction and autologous reconstruction. Compared to clinical judgment, portable Doppler devices, tissue oximetry, and fluorescein angiography, ICG angiography obviously has more benefits and usages. Conclusion ICG angiography can reveal the perfusion of flaps during the operation instantly and accurately, which refines the intraoperative strategy in order to decrease the incidence of flap-related complications. Besides, it has some economic benefits to some extent.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
  • Role of intercostal neurovascular perforator in lower abdominal flap

    Objective To investigate if intercostal neurovascular perforator can nourish lower abdominal flap. Methods Between June 2017 and December 2020, in 39 female patients with predominant perforator originated from intercostal nerve nutrient vessels, main trunk of the deep inferior epigastric vessels was chosen to be the pedicle to harvest free lower abdominal flap for breast reconstruction. The age of the patients ranged from 28 to 52 years, with an average of 38.6 years. There were 16 cases on the left and 23 cases on the right. The duration of breast cancer was 3-32 months, with an average of 21.8 months. Pathological stage was stageⅡin 31 cases and stage Ⅲ in 8 cases. Among them, 25 cases were primary tumor resection and one stage breast reconstruction and 14 cases were delayed breast reconstruction. Results The lower abdominal flap pedicled with one side pedicle was harvested in 32 cases, all of which were supplied by the main trunk of the deep inferior epigastric vessel combined with the intercostal neurovascular perforator; 7 cases were harvested with bilateral pedicled lower abdominal flaps, of which 4 cases were supplied by the main trunk of the deep inferior epigastric vessel combined with intercostal neurovascular perforator on one side and deep inferior epigastric artery perforator on the other side, and the other 3 cases were supplied by bilateral main trunk of the deep inferior epigastric vessel and the intercostal neurovascular perforator. In the flaps nourished with the main trunk of the deep inferior epigastric vessel combined with the intercostal neurovascular perforator, the intercostal neurovascular perforators were one branch type in 15 cases, one branch+reticular type in 19 sides, and reticular type in 8 sides. The size of flap ranged from 26 cm×10 cm to 31 cm×13 cm; the thickness was 2.5-5.5 cm (mean, 2.9 cm); the vascular pedicle length was 7.0-11.5 cm (mean, 9.2 cm); the weight of the flap was 350-420 g (mean, 390 g). All the flaps survived completely and the incisions at donor sites healed by first intention. All patients were followed up 14-35 months (mean, 25.4 months). The shape, texture, and elasticity of reconstructed breasts were good and no flap contracture happened. Only linear scar left at the donor site, the function of abdomen was not affected. No local recurrence happened. ConclusionWhen the direct perforator of the deep inferior epigastric artery may not provide reliable blood supply for the lower abdominal flap, the intercostal neurovascular perforator with deep inferior epigastric vessels can ensure the blood supply of the free lower abdominal flap.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content