west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LIANG Bin" 4 results
  • Interpretation of the updated 2020 American Heart Association Guidelines for Pediatric Basic and Advanced Life Support and Neonatal Resuscitation

    In October 2020, the American Heart Association issued the 2020 edition of guidelines for cardiopulmonary resuscitation and cardiovascular first aid, which comprehensively revised cardiopulmonary resuscitation and emergency cardiovascular care guidelines related to adults, children, newborns, resuscitation education science and treatment system. According to the latest edition of International Liaison Committee on Resuscitation’s classes of recommendation and levels of evidence, relevant suggestions are put forward. This article interprets the main updated and revised content, including children’s basic and advanced life support and neonatal resuscitation, in order to better guide emergency personnel and improve the quality of cardiopulmonary resuscitation and cardiovascular first aid.

    Release date:2020-12-28 09:30 Export PDF Favorites Scan
  • Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures

    ObjectiveTo compare the effectiveness of lateral approach minimally invasive plate osteosynthesis (MIPO) and helical plate MIPO in the treatment of proximal humeral shaft fractures. Methods The clinical data of patients with proximal humeral shaft fractures who underwent MIPO via lateral approach (group A, 25 cases) and MIPO with helical plate (group B, 30 cases) between December 2009 and April 2021 were retrospectively analyzed. There was no significant difference in gender, age, injured side, cause of injury, American Orthopaedic Trauma Association (OTA) fracture classification, and time from fracture to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy times, and complications were compared between two groups. The angular deformity and the fracture healing were evaluated according to anteroposterior and lateral X-ray films postoperatively. The modified University of California Los Angeles (UCLA) score for shoulder and the Mayo Elbow Performance (MEP) score for elbow were analyzed at last follow-up. Results The operation time in group A was significantly shorter than that in group B (P<0.05). However, the intraoperative blood loss and fluoroscopy times presented no significant difference between the two groups (P>0.05). All patients were followed up 12-90 months, with an average of 19.4 months. There was no significant difference in follow-up time between the two groups (P>0.05). In terms of the quality of postoperative fracture reduction, there were 4 (16.0%) and 11 (36.7%) patients with angulation deformity in group A and group B, respectively, and there was no significant difference in the incidence of angulation deformity (χ2=2.936, P=0.087). All fractures achieved bony union, there was no significant difference in fracture healing time between group A and group B (P>0.05); delayed union occurred in 2 cases and 1 case in group A and group B, respectively (healing time was 30, 42, and 36 weeks after operation, respectively). In group A and group B, 1 patient had superficial infection of incision, respectively; 2 patients and 1 patient had subacromial impact after operation, respectively; and 3 patients in group A had symptoms of radial nerve paralysis of different degrees; all of them were cured after symptomatic treatment. The overall complication incidence of group A (32%) was significantly higher than that of group B (10%) (χ2=4.125, P=0.042). At last follow-up, there was no significant difference in the modified UCLA score and MEPs score between the two groups (P>0.05). Conclusion Both lateral approach MIPO and helical plate MIPO can achieve satisfied effectiveness in the treatment of proximal humeral shaft fractures. Lateral approach MIPO may be beneficial to shorten the operation time, while the overall complication incidence of helical plate MIPO is lower.

    Release date: Export PDF Favorites Scan
  • Application of individualized transiliac crest nail-grafting guide plate in deep pelvic external fixator implantation

    Objective To explore the application of individualized transiliac crest nail-grafting guide plate prepared by computer-aided design and three-dimensional (3D) printing technology in deep pelvic external fixator implantation. Methods Five patients with pelvic fractures were collected between May 2017 and February 2018. There were 4 females and 1 male with an average age of 52 years (range, 29-68 years). Pelvic fractures were classified as type B in 3 cases and type C in 2 cases by Tile classification. The interval between injury and operation was 6-14 days (mean, 9 days). The preoperative CT images of pelvic fractures were collected. The data was reconstructed by 3D imaging reconstruction workstation. An individualized transiliac crest nail-grafting guide plate was designed on the virtual 3D model. The individualized transiliac crest nail-grafting guide plate and the solid pelvic model were produced with the 3D printing technology. The individualized transiliac crest nail-grafting guide plate was used for intraoperative deep pin position on iliac crest after the preoperative simulation. The follow-up CT scans were used to determine the differences in distance from anterior superior iliac spine, convergence angle, and caudal angle between the preoperative plan and postoperative measurement. Results During the operation, the individualized transiliac crest nail-grafting guide plate was used to guide the placement of 20 pins. X-ray film and CT examination showed that all pins were well positioned. The average depth of pins was 83.16 mm (range, 70.13-100.53 mm). Fitted 3D reconstruction images showed that the entry point and orientation of the pins were all consistent with preoperative schemes. Compared with the planned nail path, there was no significant difference in the distance from anterior superior iliac spine, convergence angle, and caudal angle in the actual nail path (P>0.05). No loosening and rupture of pin, no damage of blood vessels and nerve, and shallow or deep infection occurred during 3 months follow-up, and the incisions healed by first intention. All patients were satisfied with the treatment process. The ranges of motion of hip and knee were normal, and the visual analogue scale (VAS) score was 0-3 (mean, 0.5). Conclusion The individualized transiliac crest nail-grafting guide plate technique is the improvement of traditional technique. It can increase accuracy and effective depth of pin position, enable patients to obtain pelvic mechanical stability quickly after operation, and reduce the risk of complications related to nail path.

    Release date:2019-08-23 01:54 Export PDF Favorites Scan
  • Current situation and prospect of artificial intelligence in the diagnosis and treatment of gastrointestinal tumors using image deep learning

    ObjectiveTo summarize the application status of artificial intelligence (AI) in the diagnosis and treatment of gastrointestinal tumors using image deep learning, as well as its application prospect. MethodLiteratures on AI in the field of gastrointestinal tumors in recent years were reviewed and summarized.ResultsAI had developed rapidly in the medical field. The gastrointestinal endoscopy, imaging examination, and pathological diagnosis assisted by AI technology could assist doctors to make more accurate diagnosis opinions, and make the diagnosis and treatment of gastrointestinal tumors develop towards a more accurate and efficient direction. However, the application of AI in the medical field had just begun, and it still needed to be popularized for a long time.ConclusionThe gastrointestinal endoscopy system, imaging examination system, and pathological diagnosis assisted by AI technology all show high specificity and sensitivity, which obviously reflects its high efficiency and accuracy.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content