west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LUOYan" 6 results
  • Real-time Tissue Elastography for Evaluation of Liver Fibrosis in Patients with Type B Chronic Hepatitis

    ObjectiveTo explore the significance of quantitative parameters of tissue diffusion included in the real-time ultrasound elastography (RTE), in diagnosing the degree of liver fibrosis. MethodFrom July 2012 to November 2014, liver biopsy being the gold standard for evaluating hepatic fibrosis stage, we performed RTE on 112 hepatitis patients and analyzed the elastogram we got. At the same time, we carried out quantitative analysis of tissue diffusion in these patients, and obtained the values of liver fibrosis index (LFI) of right liver parenchyma. Subsequently, we compared the biopsy pathological results with the values of LFI, and single-factor analysis of variance (ANOVA) was adopted to compare the LFI among patients with variant degrees of liver fibrosis. If there were any discrepancies, least significant difference method would be adopted in order to compare one with the other from different groups. Finally, critical value of LFI of different-stage liver fibrosis was obtained with the help of receiver operator characteristic (ROC)curve. ResultsChronological liver fibrosis was classified into stage 0, stage 1, stage 2, stage 3, and stage 4, and their LFI values were 2.36±0.46, 2.38±0.45, 2.84±0.54, 3.16±0.59, and 3.69±0.55, respectively. ANOVA showed that the LFI values of different-stage fibrosis had significant differences (F=29.959, P<0.001). However, there was no difference between stage 0 and stage 1 (P=0.920), or between stage 2 and stage 3 (P=0.076). The area under the ROC curve for stage 0-1 and stage 2-3, stage 2-3 and S4 was respectively 0.784 and 0.799, and their critical value was 2.83 and 3.69 respectively. ConclusionsThe real-time ultrasound elastography is a feasible and non-invasive method in diagnosing the degree of hepatitis fibrosis and LFI has advantage in distinguishing different stage of liver fibrosis.

    Release date: Export PDF Favorites Scan
  • Retrospective Analysis of Ultrasound Imaging Characteristics of 58 Patients with Meckel's Diverticulum Disease

    To evaluate the ultrasound imaging characteristics and diagnostic criteria for acute abdominal Meckel's diverticulum disease (MD), we retrospectively analyzed the ultrasonic characteristics, clinical data of 58 cases of pathologically proved MD from January 2009 to May 2012. We found that among all the 58 patients, 21 patients were diagnosed with the preoperative clinical diagnosis of MD. Fourteen cases of MD inflammation with acute appendicitis were evaluated by pathological examinations after the surgery. We also found 4 cases of MD with perforation, 15 cases of MD with intussusceptions, 14 cases MD with intestinal obstruction, 5 cases of MD secondary to intestinal obstructionor intestinal necrosis, and 5 cases of MD without any obvious complications. Emergency ultrasound examinations revealed 8 cases of simple MD, 1 case of MD with intussusceptions, 9 cases of MD with acute appendicitis, 12 cases of MD with intestinal obstruction, 2 cases of MD with intussusceptions and intestinal obstruction, 1 case of MD with omphalocele and 1 case of MD with abdominal abscess. The emergency sonographic findings suggested that MD was relatively fixed bowel or thick-walled cystic mass, with one end connected to small intestine, and the other end connected to the blind side, at the periumbilicus region or at the lower right abdomen. A conclusion could be drawn that MD is difficult to be detected by ultrasound (detection rate was about 15.5%), and MD with complications such as intussusceptions, intestinal obstruction, acute appendicitis can usually be more easily detected (detection rates were 24.1%, 24.1% and 15.5%, respectively). Sonography is a simple, effective way to make diagnosis and differential diagnosis of MD with different acute abdomen symptoms from other disease.

    Release date: Export PDF Favorites Scan
  • Promotion and Application of Appropriate Health Technology in China: A Systematic Review

    ObjectiveTo systematically review the model and mechanism, efficacy and its influencing factors of the promotion and application of appropriate health technology in China. MethodsSuch database as VIP, CNKI, CBM and WanFang Data were electronically searched to collect studies on the promotion and application of appropriate health technology in China published from the establishment dates to January 2013. According to the inclusion and exclusion criteria, two reviewers independently screened literature, extracted and cross-checked data, and assessed quality. Qualitative synthesis method was used to systematically summarize the included studies. ResultsA total of 73 studies were finally included. Targeted populations included primary medical staff and personnel who provided or developed appropriate health technologies, medical institutions and their managers, as well as patients who received service or treatment of appropriate health technology. The promotion of appropriate health technologies mainly contained five fields: Chinese medicine, biomedicine, family planning services, maternal and child health, and community health services. The government-leading model had been widely applied currently, besides, there were other four models: government-guidance, government-driven, market-leading and a third sector-leading models. Factors related to project funding, organization and management, technology holders, the supply and demand parties in technical services and technology itself might affect the application of appropriate health technology. Among all evaluation studies, the number of needs assessment was less, the contents of process evaluation were one-sided and the effect evaluation was mainly cross-sectional studies. ConclusionThis study shows that sustainable development of appropriate health technology promotion model need to fully consider market demand and people's needs, on the basis of using government-leading or introducing a third sector-leading model. Corresponding measures should be taken according to the influencing factors of promotion and application of appropriate health technology. It is necessary to conduct high quality evaluation studies in future and comprehensively evaluate the efficacy of the promotion and application of appropriate health technology.

    Release date: Export PDF Favorites Scan
  • The Value of Ultrasound Evaluation and Marking before Arteriovenous Internal Fistula in Uremia Patients

    ObjectiveTo explore the value of ultrasound evaluation and marking before arteriovenous internal fistula in end-stage renal disease hemodialysis patients. MethodsTwenty-five uremia end-stage patients were admitted into our nephrology department from January 2012 to July 2012. All of the patients had encountered several times of fistula failure or had difficulty in establishing the forearm arteriovenous fistula. We focused on observing the brachial artery, radial artery, cephalic vein, the basilica vein and great saphenous vein. We measured the diameter of the vessels and marked the trend of arteries and veins in the body surface under the ultrasonic navigation. Our goal was to look for appropriate bypass vessels in the elbow and the upper arm. ResultsFourteen patients had endured several times of fistula failure. Among the 14 patients, 9 patients completed the surgery of reengineering fistula and autogenous great saphenous vein transplantation, 2 accepted artificial vascular transplantation, 1 completed the removal of blood clots in the left upper limb artificial blood vessels and arteriovenous internal fistula molding, and 2 gave up surgery. Eleven patients could not complete the arteriovenous fistula operation for the fine forearm superficial vein. Of them, 2 patients accepted artificial vascular operation, 6 underwent autogenous great saphenous vein transplantation, 1 with slender radial artery in diameter completed higher position fistula between the brachial artery and median cubital vein, and 2 gave up surgery. ConclusionArteriovenous internal fistula preoperative ultrasound assessment and marking have very important value in improving the success rate of operation in end-stage uremia patients.

    Release date: Export PDF Favorites Scan
  • Discussion on Ultrasound Physician and Sonographer Integrated Work Mode

    Ultrasound Medicine has been through a rapid development during the past half century and has become an indispensable discipline for prophylactic medicine and clinical practice. Nowadays, the needs for ultrasound medicine diverse which leads to many challenges to the existing ultrasound physician scanning - diagnostic mode, including labor-intensiveness for the ultrasound physician, lacking of hierarchical management, contradiction of quality and quantity, irrational allocation of medical resources, and so on. This paper discussed several issues including the current situation of ultrasound education, domestic and western ultrasound work mode, necessity for ultrasound physician- sonographer integrated work mode, as well as the feasibility of standardized sonographer training. Combined with the experience of the West China Hospital, explore a Chinese way to carry out sonographer education and training program and try out ultrasound physician-sonographer integration mode.

    Release date: Export PDF Favorites Scan
  • Clinical Application of Hemodilution Autotransfusion in Liver Resection for Patients with Hepatic Echinococcosis

    ObjectiveTo evaluate the effect of dilute autotransfusion in liver resection for patients with hepatic hydatid disease. MethodThirty patients with hepatic hydatid disease met the inclusion criteria were included. The changes of intraoperative hemodynamics, internal environment, and each system functions at different time point were observed. Results①There were no significant differences among mean arterial pressure, central venous pressure, heart rate in all the patients at each time point (P > 0.05), while, the other indexes including the concentrations of hemoglobin (Hb), hematocrit (Hct) after blood collection were all greatly lower than those before blood collection (P < 0.05), Na+, K+, Cl-, pH, and base excess after blood collection were all greatly lower than those before blood collection (P < 0.05). But all the indexes above mentioned (except for ph and base excess) returned to normal.②Compared with these indicators before surgery, the blood concentrations of AST, ALT, cardiac troponin I, and creatinin were all greatly increased (P < 0.05), the blood concentrations of Hb, Hct, platelet were all decreased apparently after surgery 1 day (P < 0.05). The prothrombin time and activated partial thromboplastin time were all prolonged (P < 0.05). But after surgery one week, those indicators had rebounded to the normal range. ConclusionThe application of dilute autotransfusion in liver surgery for patients with hepatic hydatid disease is safe, feasible, and saving.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content