west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "MA Hailong" 6 results
  • Effectiveness comparison of two surgical methods in treatment of intra-articular displaced calcaneal fractures in older children

    Objective To compare the effectiveness of open reduction and internal fixation with plate and closed reduction and internal fixation with Kirschner wire (K-wire) in the treatment of intra-articular displaced calcaneal fractures in older children. MethodsA clinical data of 35 older children (37 feet) with intra-articular displaced calcaneal fractures who were admitted between November 2014 and November 2020 and met the selection criteria were retrospectively analyzed. Among them, 19 cases (20 feet) underwent open reduction and internal fixation with plate (plate group), and 16 cases (17 feet) underwent closed reduction and internal fixation with K-wire (K-wire group). There was no significant difference in gender, age, cause of injury, side and type of fracture, and time from injury to admission, and preoperative calcaneal Gissane angle and Böhler angle (P>0.05). The postoperative calcaneal Gissane angle, Böhler angle, complications, and fracture healing were compared between the two groups. The ankle function was evaluated based on the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot scoring system. Results Incision necrosis occurred in 1 foot in the plate group after operation, which healed after symptomatic treatment; the other incisions in the two groups healed by first intention. All children were followed up 12-39 months (mean, 19 months). X-ray films showed that the fractures in both groups healed; the healing time was (2.65±0.71) months in the plate group and (2.24±1.38) months in the K-wire group respectively, with no significant difference (t=1.161, P=0.253). At last follow-up, the calcaneal Gissane angle and Böhler angle returned to normal; and the difference between pre- and post-operation in the two group was significant (P<0.05), but there was no significant difference between the two groups in the difference between before and after operation (P>0.05). In the plate group, the plate was removed at 11-22 months after operation (mean, 16.8 months). At last follow-up, the AOFAS ankle-hindfoot score in the plate group was 91.2±5.1, which was significantly higher than that in the K-wire group (86.9±6.1) (t=2.316, P=0.027). The ankle function was rated as excellent in 15 feet, good in 4 feet, and fair in 1 foot in the plate group, and excellent in 14 feet and good in 3 feet in the K-wire group, and the difference between the two groups was not significant (Z=1.712, P=0.092). ConclusionFor intra-articular displaced calcaneal fracture in older children, the open reduction and internal fixation with plate and closed reduction and internal fixation with K-wire can achieve good effectiveness, but the former has better recovery of ankle function.

    Release date: Export PDF Favorites Scan
  • Comparative study on effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in treatment of Jakob type Ⅱ lateral condylar humerus fractures in children

    Objective To compare the effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ lateral condylar humerus fracture (LCHF) in children. Methods A clinical data of 101 children with Jakob type Ⅱ LCHF, who met the selection criteria and were admitted between April 2021 and April 2022, was retrospectively analyzed. Of them, 47 cases were treated with ultrasound-assisted Kirschner wire fixation (group A), and 54 cases with arthrography-assisted surgery (group B). There was no significant difference in gender, age, cause of injury, fracture side, and disease duration between groups (P>0.05). Intraoperative fluoroscopy times, operation time, and hospital stay, Flynn elbow joint function score, and postoperative complications were recorded and compared between groups. X-ray examination was performed to observe the healing of fracture, and measure the carrying angle and the shaft-condylar angle (SCA). ResultsThe success rate of closed reduction was significantly higher in group A than in group B (P<0.05), and the intraoperative fluoroscopy times was significantly less in group A than in group B (P<0.05). There was no significant difference in operation time and hospital stay between groups (P>0.05). All children in both groups were followed up 12-18 months, with an average of 13.6 months. X-ray reexamination showed that the fractures of both groups healed, and the difference in healing time was not significant (P>0.05). At last follow-up, there was no significant difference in carrying angle and SCA between unaffected side and affected side in both groups and between groups A and B in affected side (P>0.05). There was no significant difference in Flynn elbow joint function score between groups (P>0.05). There were 18 cases of lateral spurs formation in group A, 1 case of pinning infection and 26 cases of lateral spurs formation in group B, and there was no significant difference in the incidence of the above complications (P>0.05). ConclusionCompared with the arthrography, the ultrasound-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ LCHF in children can avoid the open reduction and decrease the number of intraoperative fluoroscopy, and obtain the good effectiveness.

    Release date: Export PDF Favorites Scan
  • Reconstruction of medial and lateral column periosteal hinge using Kirschner wire to assist in closed reduction of multi-directional unstable humeral supracondylar fractures in children

    Objective To investigate the effectiveness of medial and lateral column periosteal hinge reconstruction using Kirschner wire in the closed reduction of multi-directional unstable humeral supracondylar fractures in children. Methods A clinical data of 43 children with multi-direction unstable humeral supracondylar fractures, who met the selection criteria and were admitted between August 2020 and August 2022, was retrospectively analyzed. Twenty-one cases of fractures were treated wuth closed reduction after medial and lateral column periosteal hinge reconstruction using Kirschner wire and percutaneous Kirschner wires fixation (study group), while 22 cases of fractures were treated by traditional closed reduction technique and percutaneous Kirschner wire fixation (control group). There was no significant difference in gender, age, cause of injury, fracture side, and interval from injury to operation between the two groups (P>0.05). The operation time, intraoperative fluoroscopy times, the number of children who were changed to open reduction after closed reduction failure, fracture healing time, complications within 2 months after operation, and the Flynn score of elbow joint function at last follow-up were compared between the two groups. ResultsAll the fractures in the study group were successfully closed reduction, and 4 cases in the control group were changed to open reduction and completed the operation, the difference between the two groups was significant (P=0.040). The operation time and intraoperative fluoroscopy times of the study group were significantly less than those of the control group (P<0.05). All children in both groups were followed up 6-18 months with an average of 9.0 months in the study group and 9.8 months in the control group. Imaging review showed that the fractures of both groups healed, and the difference in the healing time between the two groups was not significant (P=0.373). According to Flynn score at last follow-up, the excellent and good rate of elbow joint function was 95.2% (20/21) in the study group and 86.4% (19/22) in the control group, with no significant difference (P=0.317). There was no complication such as infection or irritation at the end of Kirchner wire within 2 months after operation. Conclusion For children with multi-directional unstable humeral supracondylar fractures, the use of Kirschner wires to reconstruct the medial and lateral column periosteal hinge to assist in closed reduction has the advantages of shortening operation time, reducing intraoperative fluoroscopy times, and effectively reducing the incidence of open reduction, and can achieve similar postoperative elbow joint function when compared with traditional closed reduction technique.

    Release date: Export PDF Favorites Scan
  • Effectiveness comparison of ultrasound-guided closed reduction and Kirschner wire fixation for different unstable humeral lateralcondylar fractures of children

    ObjectiveTo compare the effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation for different unstable humeral lateralcondylar fractures of children. Methods The clinical data of 94 children with unstable humeral lateralcondylar fractures admitted to three medical centers between January 2021 and October 2022 were retrospectively analyzed. The children were divided into three groups according to the Song classification and whether the elbow joint was dislocated or not, including 42 cases of Song 4 type (group A), 38 cases of Song 5 type (group B), and 14 cases of elbow joint dislocation (group C). There was no significant difference in gender, age, side, cause of injury, and time from injury to operation among the three groups (P>0.05). All children were treated with ultrasound-guided closed reduction and Kirschner wire fixation. The operation time and complications of the three groups were recorded and compared, and the failure of closed reduction was evaluated by ultrasound. X-ray examination was performed at last follow-up to measure the Baumann angle, condylar angle, carrying angle, and lateral osteophyte of the affected side; the extension, flexion, pronation, and supination range of motion of the affected elbow joint were measured; the function of the elbow joint was evaluated by Mayo score. ResultsThe operation time in group A was significantly longer than that in groups B and C (P<0.05). There were 7, 2, and 5 cases of closed reduction failure in groups A, B, and C, respectively, and there was no significant difference in the incidence of the closed reduction failure (P>0.05). All patients were followed up 6-28 months, with an average of 15.7 months. There was no significant difference in the follow-up time among the three groups (P>0.05). Complications: in group A, there were 2 cases of delayed union, 4 cases of needle tract infection, 1 case of trochlear necrosis, and 39 cases of lateral osteophyte; in group B, there was 1 case of malunion, 5 cases of needle tract infection, 1 case of redisplacement, and 26 cases of lateral osteophyte; in group C, there were 2 cases of needle tract infection and 10 cases of lateral osteophyte. There was no significant difference in the incidence of complications among the three groups (P>0.05). No cubitus varus or cubitus valgus deformity was found in all patients. At last follow-up, except that the condylar angle in group A was significantly greater than that in groups B and C (P<0.05), there was no significant difference in other imaging indicators, elbow range of motion, or Mayo score between groups (P>0.05). ConclusionThe Song type 4 of humeral lateralcondylar fracture treated with ultrasound-guided closed reduction and Kirschner wire fixation has a longer operation time, more postoperative complications, and is more prone to lateral osteophyte.

    Release date: Export PDF Favorites Scan
  • Application of thumb blocking technique with ulnar Kirschner wire threading for Gartland type Ⅲ supracondylar humerus fractures in children

    Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.

    Release date: Export PDF Favorites Scan
  • Short-term effectiveness of ultrasound-guided Kirschner wire provocation technique in treatment of Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents

    Objective To investigate the short-term effectiveness of ultrasound-guided closed reduction by Kirschner wire provocation technique in the treatment of Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents. Methods Between May 2019 and May 2022, 41 patients with Salter Harris types Ⅰ and Ⅱ distal tibial epiphyseal fractures were admitted, all of whom had periosteal entrapment on preoperative MRI, and 38 cases (92.7%) were confirmed to have periosteal entrapment by intraoperative ultrasound. There were 24 males and 14 females, the age ranged from 6.8 to 15.7 years, with an average of 10.7 years; and there were 20 cases of Salter Harris type Ⅰ and 18 cases of type Ⅱ. The time from injury to operation was 22-76 hours, with an average of 28.4 hours. The preoperative imaging examination showed excellent alignment in 4 cases, good in 20 cases, and poor in 14 cases. The ultrasound guided Kirschner wire provocation technique for closed reduction and percutaneous Kirschner wire internal fixation were performed. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Anteroposterior and lateral X-ray films of the affected ankle joint were taken before operation, at 3 months after operation, and at last follow-up to observe the healing of the fracture, and anteroposterior X-ray films of the whole length of both lower limbs were taken to evaluate the alignment of the force lines of the affected limbs. The range of motion (ROM), visual analogue scale (VAS) score, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score were used to evaluate ankle function. The mechanical lateral distal tibia angle (mLDTA) and the anatomic anterior distal tibia angle (aADTA) were measured. Results The operation time ranged from 17 to 52 minutes, with an average of 22.6 minutes, and the intraoperative fluoroscopy frequency ranged from 3 to 11 times, with an average of 4.2 times. X-ray examination during operation and at 2 days after operation showed that anatomical reduction was achieved. All patients were followed up 10-24 months, with an average of 16.4 months. All fractures healed in 6.1-7.2 weeks, with an average of 6.3 weeks; no fracture displacement occurred, and the patients recovered to their pre-injury level of motion at 6 months after operation. Needle tail irritation occurred in 2 cases at 4 weeks after operation, and they recovered after symptomatic treatment. During the follow-up, there was no serious complication such as incision deep infection, bone nonunion, delayed union, and malunion. At last follow-up, the patients’ alignment were all excellent, and the difference was significant when compared with preoperative one (Z=–7.471, P<0.001). The VAS score, AOFAS ankle-hindfoot score, dorsiflexion-plantar flexion ROM, varus-valgus ROM, mLDTA, and aADTA significantly improved at 3 months after operation and last follow-up when compared with preoperative ones (P<0.05). ConclusionUltrasound-guided closed reduction by Kirschner wire provocation technique for treating Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents is minimally invasive and safe.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content