find Keyword "Macular lutea" 6 results
  • The application of 25G vitrectomy system in macular diseases

    Objective To evaluate the 25-gauge (25G) transconjunctival sutureless vitrectomy system (TSV25G) for macular diseases. Methods The clinical data of 18 patients with macular diseases treated by the TSV25G were retrospectively analyzed. The 18 patients included 13 men and 5 women, aged from 25 to 73 years. The disease course ranged from 3.5 to 10 months, in cluding 8 epiretinal membrane, 3 idiopathic macular hole, 3 tranumatic macular hole with submacular heamorrhage, 2 vitreo-macular tractional syntrome and 2 diabetic macular edema. The surgical parameter installation was as follows: high speed cutter with rate of 1500 cuts per minute; the maximum aspiration with a TSV2 5G were 500-550 mmHg (1 mm Hg=0.133 kPa); the BSS bottle height was 40-50 cm; the intraocular pressure was 29-35 mmHg during the surgery. The postoperative follow-up period was 2.5-10 months. Results Eighteen patients had undergone the vitrectomy successfully with the operative time of 26-44 minutes (mean 35 minutes). No complication was found. Water leakage of the puncture site was found in 1 patient and was sewed up with 8-0 absorbable sutures. The mean time of inpatients were 3.5 days postoperatively. In the postoperative follow-up in 18 patients, the macular edema disappeared totally in 12 patients 3-6 months after the operation; the visual distortion disappeared in 10 and alleviated in 2; the visual acuity regained (0.8 or more) in 6 (33.3%), not changed in 4, and improved in 2. Conclusion TSV25G was safe, time-saving, and effective for macular diseases. (Chin J Ocul Fundus Dis,2004,20:137-138)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • The clinical observation of the relationship between the macular pigment and the foveal cone function

    Objective To test the hypothesis that the macular pigment may be a marker of foveal cone function and consequently the structural integrity of foveal cones.Methods Sixteen patients (32 eyes) diagnosed to have Stargardt dystrophy and three patients with full thickness macular holes by clinical criteria were studied with a scanning laser ophthalmoscopy (SLO) comparing argon laser blue and infrared images for the presence or absence of macular pigment (MP) in the fovea. An C++ computer based program was used to evaluate the density of MP. Eyes were graded into three categories: those without foveal macular pigment, those with partial pigment and those with normal amounts of macular pigment. These categories were compared with visual acuity determined by the Snellen chart. Results Thirteen eyes with a visual acuity of 20/200 or worse had no macular pigment in the fovea. Eleven eyes with visual acuity of 20/40 or better had a normal amount of macular pigment in the fovea and 1 eye had partial macular pigment. Eleven eyes with partial macular pigment had intermediary acuity value.Conclusions Foveal macular pigment is closely related to foveal cone acuity and therefore may be a marker for the presence of foveal cones. Infrared light is a sensitive indicator of early macular diseases.(Chin J Ocul Fundus Dis,2003,19:201-268)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • Morphological assessment of macular hole surgery by scanning laser tomography

    Purpose To explore the role of scanning laser tomography in the assessment of macular hole surgery. Methods Fifteen eyes of 14 patients with macular holes underwent scanning of their affected macular area using the Heidelberg retina tomograph (HRT). The significance of topographic changes postoperatively were determined in eleven eyes which received vitrectomy surgery. The scan field was set at 15°of the retina and the depth was set to 1.5 mm or 2.0 mm. All the measurements were taken for 3 times and the average value of the 3 measurements was used. Results The average hole area was (0.499±0.34) mm 2 and the maximal depth of the hole was (0.284±0.11) mm. Topographic difference analysis of the eleven eyes showed a significant reduction in the height of the retina after vitrectomy. The maximal depth of the hole was (0.063±0.04) mm postoperatively. Conclusion Scanning laser tomography provides an objective evaluation of the anatomic outcome of the macular hole surgery. (Chin J Ocul Fundus Dis, 2002, 18: 125-127)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • The changes of optical coherence tomography images of the macula after phacoemul sification in diabetics 

    Objective To investigate the effects of phacoemulsification on macula in diabetics. Methods Thirty eyes of cataract in diabetics were chosen randomly for measurement of the thickness of fovea of retina using OCT before phacoemulsification and 1 month after surgery . The other eyes in these patients and 30 eyes of cataract in nondiabetic pati ents with phacoemulsification were as control. Results In 30 eyes of diabetics with phacoemulsification, the mean fovea thickness were (148.5plusmn;27.7) mu;m preoperatively and (219.4plusmn;68.23) mu;m postoperatively, and the difference was significant (Plt;0.05). In 30 eyes of diabetics without surgery, the mean foveal thickness were (147.4plusmn;27.5) mu;m preoperatively and (148.2plusmn;27.3) mu;m postoperatively and the difference was not significant (Pgt;0.05). In 30 eyes of cataract in nondiabetic patients, the mean fovea thickness were (142.37plusmn;12.7) mu;m preoperatively and (151.9plusmn;23.7) mu;m postoperatively and the difference was not significant (Pgt;0.05). In 30 eyes of diabetic s with phacoemulsification, 11 eyes had new macula edema after surgery and 3 eye s had significant retinal thickening. In 6 eyes with macular edema before surgery, the macular edema were aggravated in 3 eyes after surgery. The macular stru ctural changes were not found in two control groups. Conclusion The thickness of retina is inreased after phacoemulsification in deabetics,and morbidity and its severity of postopevative macular edema are increas ed as well. (Chin J Ocul Fundus Dis, 2001,17:175-177)

    Release date:2016-09-02 06:03 Export PDF Favorites Scan
  • The multi-focal electroretinogram of Stargardt′s disease

    Purpose To observe the features of multi-focal electroretinogram (mERG) in Stargardtprime;s disease, and evaluate the validity of mE RG on diagnosis of this disease. Methods mERG had been recorded in 7 cases (14 eyes) of Stargardtprime;s disease with VERIS 4.0,and the findings were compared with normal individuals. Results The mERG were remarkably abnormal in all cases of the disease, as the amplitudes of N1 and P1 waves were seriously decreased and the latencies were prolonged in all the 6 regions (Plt;0.01). The degrees of the amplitude changes of N1, P1 waves were not the same in those areas,and the most decreased part was in fovea. The responses of N1, P1waves from the fovea of patients were about 19 and 10 percent respectively of which in controls. As the eccentricity enlarged, these differences had a tendency of reduction. The mERG topography of this disease could be divided to two types, i.e. central decreased and diffuse decreased types. Conclusion There are remarkably abnormalities on mERG in Stargardtprime;s disease,and the most damaged location of macular function is in fovea. (Chin J Ocul Fundus Dis, 2001,17:271-273)

    Release date:2016-09-02 06:03 Export PDF Favorites Scan
  • Exploration of the factors which affect the size of diabetic macular foveal avascular zone

    Objective To expolre the factors which affect the size of diabetic,macular fobeal avascss scular zone(FAZ). Methods Making ten years of duration of diabetes a limit,79 nonproliferative and early proliferative diabetic patients were divided into 2 groups.Diabetic retinopathy severity level was diveided into 4 stages,and the macular edema was subdivided into focal、diffuse and cystoid according to fluorescein leakage of foveomacular region.All patients were measured FAZ with Heidelberg scanning laser fluoresceion angiography system and then compaired the size of FAZ of patients with different duration of diabetes、diabetic retinopathy severity level and macular edema status.The results were performed analysis of variance and t test. ResultsThe study shown the size of FAZ was not directly related to the duration of diabetes(t=1.3854,Pgt;0.1);There were significant differences about the size of FAZ of patients with different diabetic retinopathy severity level(F=7.6251,P<0.01)and macular edema status(F=5.4369,P<0.01). Conclusion The size of FAZ was significantly increased in diabetic patients.It was enlarged with the development of diabetic retinopathy severity level,but it was not related to duration of diabetes. (Chin J Ocul Fundus Dis,2000,16:155-156)

    Release date:2016-09-02 06:05 Export PDF Favorites Scan