west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Magnesium alloy" 4 results
  • BIOCOMPATIBILITY OF SILICON CONTAINING MICRO-ARC OXIDATION COATED MAGNESIUM ALLOY ZK60 WITH OSTEOBLASTS CULTURED IN VITRO

    Objective To research in vitro biocompatibility of silicon containing micro-arc oxidation (MAO) coated magnesium alloy ZK60 with osteoblasts. Methods The surface microstructure of silicon containing MAO coated magnesium alloy ZK60 was observed by a scanning electron microscopy (SEM), and chemical composition of the coating surface was determined by energy dispersive spectrum analysis. The experiments were divided into 4 groups: silicon containing MAO coated magnesium alloy ZK60 group (group A), uncoated magnesium alloy ZK60 group (group B), titanium alloy group (group C), and negative control group (group D). Extracts were prepared respectively with the surface area to extraction medium ratio (1.25 cm2/ mL) according to ISO 10993-12 standard in groups A, B, and C, and were used to culture osteoblasts MC3T3-E1. The α-MEM medium supplemented with 10% fetal bovine serum was used as negative control in group D. The cell morphology was observed by inverted phase contrast microscopy. MTT assay was used to determine the cell viability. The activity of alkaline phosphatase (ALP) was detected. Cell attachment morphology on the surface of different samples was observed by SEM. The capability of protein adsorption of the coating surface was assayed, then DAPI and calcein-AM/ethidium homodimer 1 (calcein-AM/EthD-1) staining were carried out to observe cell adhesion and growth status. Results The surface characterization showed a rough and porous layer with major composition of Mg, O, and Si on the surface of silicon containing MAO coated magnesium alloy ZK60 by SEM. After cultured with the extract, cells grew well and presented good shape in all groups by inverted phase contrast microscopy, group A was even better than the other groups. At 5 days, MTT assay showed that group A presented a higher cell proliferation than the other groups (P lt; 0.05). Osteoblasts in groups A and C presented a better cell extension than group B under SEM, and group A exhibited better cell adhesion and affinity. Protein adsorption in group A [ (152.7 ± 6.3) µg/mL] was significantly higher than that of group B [(96.3 ± 3.9) µg/mL] and group C [ (96.1 ± 8.7) µg/mL] (P lt; 0.05). At each time point, the adherent cells on the sample surface of group A were significantly more than those of groups B and C (P lt; 0.05). The calcein-AM/EthD-1 staining showed that groups A and C presented better cell adhesion and growth status than group B. The ALP activities in groups A and B were 15.55 ± 0.29 and 13.75 ± 0.44 respectively, which were significantly higher than those in group C (10.43 ± 0.79) and group D (10.73 ± 0.47) (P lt; 0.05), and group A was significantly higher than group B (P lt; 0.05). Conclusion The silicon containing MAO coated magnesium alloy ZK60 has obvious promoting effects on the proliferation, adhesion, and differentiation of osteoblasts, showing a good biocompatibility, so it might be an ideal surface modification method on magnesium alloys.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • PROGRESS OF IN VIVO STUDY ON DEGRADABLE MAGNESIUM ALLOYS APPLICATION AS BONE-IMPLANT MATERIALS

    Objective To review the progress of in vivo study on degradable magnesium alloys application as bone-implant materials. Methods Recent literature was extensively reviewed and summarized, concerning the in vivo study on degradable magnesium alloys as orthopaedic implants. Results Magnesium alloys possess a natural ability to degrade via corrosion in vivo, which is promising candidate material for orthopaedic medical device applications. A great progress has been made to improve in vivo performance and integration with bone tissue. However, the degradation mechanism of magnesium-based materials in the physiological environment and long-term effect on body are not available. The modulation of the corrosion rate of magnesium alloys must also be accomplished. Conclusion Magnesium alloys have the potential to serve as degradable implants for orthopaedic applications, but a great deal of further investigation is still necessary.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • In vivo degradation of magnesium alloys and poly (lactic-co-glycolic acid) and degradation evaluation of magnesium alloys using micro-ct

    ObjectiveTo explore the degradation of AZ31 magnesium alloy and poly (lactic-co-glycolic acid) (PLGA) in the femoral condyle, and then evaluate the laws of degradation of AZ31 magnesium alloy by Micro-CT images and data. MethodsForty 3-month-old male New Zealand white rabbits (weighing, 2.5 kg) were randomly divided into 4 groups, 10 rabbits each group. Forty micro-arc-oxidized AZ31 magnesium alloy pins and 40 PLGA pins were implanted into the right and left femoral condyle, respectively. Micro-CT images and data analysis were used to evaluate the degradation at 4, 8, 12, and 16 weeks after operation (n=10). Degradation was evaluated by weight difference between pre-and post-implantation. The inflammatory response was observed around the implants by HE staining. The weight loss of magnesium alloy and Micro-CT results were compared. ResultsThe Micro-CT images showed that PLGA pins had gray low signal, which was similar to the soft tissue around. At 4 weeks after operation, no signs of degradation were observed, and there were little corrosion pitting on the magnesium alloy. At 8 weeks, corrosion pitting gradually expanded, the boundary between the longitudinal axis and the cross section became blurred; at 16 weeks, corrosion pitting became bigger, and the boundary was discontinuous. Micro-CT quantitative analysis showed that the volume fraction of magnesium pins decreased slowly at 4 and 8 weeks; it was significantly lower at 12 and 16 weeks than 4 and 8 weeks (P < 0.05). The magnesium cylinder mineral density continuously decreased during the study period, it had a rapidly speed from 12 to 16 weeks (P < 0.05). However, the magnesium CT image density showed a slight change (P>0.05). The surface-to-volume ratio of the pins constantly increased, and the ratio was significantly larger at 12 and 16 weeks than 4 and 8 weeks, and at 16 weeks than 12 weeks (P < 0.05). There was more and more corrosion pitting on the surface with time, which resulted in a decrease in the radius that mean trabecular thickness gradually decreased, showing significant difference between different time points after 8 weeks (P < 0.05). The weight loss detection showed that the degradation of magnesium pin and PLGA gradually increased with time (P < 0.05), and the degradation rate of magnesium pin was significantly lower than that of PLGA at 8-12 weeks (P < 0.05), but the degradation rate of magnesium pin was higher than that of PLGA at 16 weeks. At each time point, the weight loss of magnesium alloy was similar to that by Micro-CT, but mass fraction was lower than volume fraction and had significant differences at 8, 12, and 16 weeks (P < 0.05). HE staining revealed that slight inflammatory response was observed around the magnesium pins at 4 weeks, and inflammatory reaction gradually reduced with time and disappeared at 16 weeks, but no inflammatory reaction was seen around PLGA. ConclusionMicro-CT has the advantages of non-trauma, in vivo detection, quantitative analysis, and precise data in evaluating the degradation of AZ31 magnesium alloy. Regarding the degradation of the magnesium alloy and PLGA in vivo, the degradation rate is slow in the early stage, and then increases with time. The degradation of PLGA is faster and earlier but it is then overtaken by AZ31 magnesium alloy at 16 weeks. During the degradation, the density of the magnesium has almost no change. The biomaterials can not firmly attach to the surrounding tissues due to inadequate holding forces.

    Release date: Export PDF Favorites Scan
  • RESEARCH PROGRESS OF MAGNESIUM AND MAGNESIUM ALLOYS IMPLANTS IN ORTHOPEDICS

    ObjectiveTo summarize the research and application progress of magnesium and magnesium alloys implants in the orthopedics. MethodsThe domestic and foreign related literature about the research progress and application of magnesium and magnesium alloys implants in the orthopedics was reviewed. ResultsCurrently approved and commonly used metallic implants in orthopedics include stainless steels, titanium alloys, and chromium alloys having many disadvantages of poor biocompatibility, mismatch with the biomechanical properties of the bone tissue, and need of second surgical procedure to remove. Compared with traditional implants, magnesium and magnesium alloys have biomechanical properties closer to natural bone tissue, and in vivo degradation, which have the potential to serve as new biocompatible and degradable implants. Although magnesium and magnesium alloy materials have their own advantages, but the degradation rate is still too fast and so on. At present, the research and development of medical magnesium and magnesium alloy materials are to improve their corrosion resistance and control the rate of degradation. ConclusionMagnesium and magnesium alloys have great potential as a implant material in the orthopedics, through further systematic and in-depth study, it is expected to become a new generation of degradation biological implant materials.

    Release date:2016-12-12 09:20 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content