Objective To analyze the effectiveness of combined treatment of lumbar spondylolisthesis with MED, Quadrant, and Sextant-R systems. Methods Between August 2006 and June 2011, 35 patients with lumbar spondylolisthesis were treated, including 11 cases of isthmic spondylolisthesis and 24 cases of degenerative spondylolisthesis. There were 25 males and 10 females, with a mean age of 55 years (range, 33-71 years). The mean disease duration was 37 months (range, 8-75 months). Spondylolisthesis occurred at L4, 5 level in 21 patients and at L5, S1 level in 14 patients. According to Meyerding classification, 35 cases were rated as dergee I. The minimally invasive surgeries were performed by paraspinal muscle approach; Quadrant system was used for decompression and fusion at severe side, MED system for windowing of lamina at mild side, and Sextant-R system for fixation and reduction. Visual analogue scale (VAS) score was used to evaluate pain, Oswestry disability index (ODI) to evaluate clinical outcomes, spondylolishesis ratio and intervertebral height to evaluate spondylolisthesis reduction. Results Lumbar continuous thin layer CT at postoperation showed that no pedicle screw invaded spinal canal and intervertebral fusion device was at good position. Incisions healed by first intention. All patients were followed up 18-38 months (mean, 26 months). All patients got bone fusion and had no internal fixation failure by radiologic examination at 1 year after operation. Low back pain was relieved, lumbar function improved obviously, and satisfactory reduction of spondylolisthesis was obtained. At 2 weeks and 1 year after operation, the VAS score, ODI score, spondylolisthesis ratio, and intervertebral height were significantly improved when compared with preoperative ones (P lt; 0.05). VAS score and ODI score showed significant differences (P lt; 0.05) between at 2 weeks and 1 year after operation. Spondylolisthesis ratio and intervertebral height showed no significant difference (P gt; 0.05) between at 2 weeks and at 1 year after operation. Conclusion Minimally invasive surgical management for lumbar spondylolisthesis via MED, Quadrant, and Sextant-R systems is a safe and effective surgical technique. However, its indications should be well considered.
【Abstract】 Objective To explore the effectiveness of bone grafting by intervertebral disc endoscope for postoperativenonunion of fracture of lower limb. Methods Between August 2004 and August 2008, 40 patients (23 males and 17 females) with postoperative nonunion of femoral and tibial fracture, aged 20-63 years (mean, 41.5 years) were treated. Nonunion of fracture occurred at 10-16 months after internal fixation. During the first operation, the internal fixation included interlocking intramedullary nail ing of femoral fracture in 12 cases and plate in 16 cases, and interlocking intramedullary nail ing of tibial fractures in 9 cases and plate in 3 cases. The X-ray films showed hypertrophic nonunion in 24 cases, common nonunion in 3 cases, and atrophic nonunion in 13 cases. Results The average operation time was 61 minutes (range, 40-80 minutes), and the blood loss was 80-130 mL (mean, 100 mL). The hospital ization time were 6-11 days (mean, 8.1 days). Incisions healed by first intention in all patients with no complication of infection or neurovascular injury. Forty patients were followed up 10-16 months (mean, 12.3 months). The X-ray films showed that all patients achieved healing of fracture after 4-10 months (mean, 6.8 months). No pain, disfunction, or internal fixation failure occurred. Conclusion Bone grafting by intervertebral disc endoscope is an effective method for treating postoperative nonunion of femoral and tibial fracture.
Objective To evaluate the security and effectiveness of minimal invasive fixation with three dimensional (3D) fluoro-images based on navigation system in the management of acetabular fractures. Methods Between August 2008 and January 2010, 12 patients with acetabular fractures were treated with percutaneous screw fixation under the guidance of 3D fluoro-images based on navigation system after closed reduction. There were 7 males and 5 females, aged 28-57 years (mean, 38.1 years). Fractures were caused by traffic accident in 9 cases, and fall ing from height in 3 cases. According to AO classification, there were 1 case of A2.2 type, 3 cases of A2.3 type, 2 cases of A3.2 type, 2 cases of A3.3 type, 1 case of B2.2 type, 1 case of B3.2 type, 1 case of C2.1 type, and 1 case of C2.3 type. The interval from injury to hospital ization was 4 hours to 3 days (mean, 1.2 days). Results Totally 28 screws were implanted. The average time to implant 1 screw was 24.8 minutes. Twenty-seven screws were placed correctly with a successful rate of 96.4%, only 1 screw was reinserted for deviation. All the screws were checked by the 3D fluoro-images, which showed they were not in the joint space after fixation. The results were the same as that by CT scanning. Incisions healed by first intention, and no implant failure occurred. All 12 patients were followed up 7 to 24 months with an average of 16.8 months. At last follow-up, fracture union was achieved in all patients with satisfactory screw fixation. Conclusion The minimal invasive fixation with 3D fluoro-images based on navigation system makes the surgery for the nondisplaced acetabular fracture more precise and time-saving, minimizes the surgery injury, and improves the cl inical results with less compl ications.
Objective To compare the cl inical results of two plating osteosynthesis techniques, open reduction and plating ostosynthesis (ORPO) and minimal invasive plating osteosynthesis (MIPO), in surgical treatment of mid-distal humeralshaft fractures. Methods From March 2004 to October 2006, 40 cases of closed unilateral mid-distal humeral shaft fractures were surgically treated with MIPO or ORPO. In the MIPO treated group (n=19), there were 14 males and 5 females, with a mean age of 39.05 years. Fractures involved in middle humeral shaft in 10 cases and distal fragment in 9 cases. According to OTA classification, there were 3 cases of type A, 13 cases of type B and 3 cases of type C. Four cases compl icated by radial nerve palsies. In the ORPO treated group (n=21), there were 13 males and 8 females with a mean age of 39.05 years, including 14 cases of type A and 7 cases of type B fractures according to OTA classification. The fractures involved in middle humeral shaft in 13 cases and distal fragment in 8 cases. Five cases compl icated by radial nerve palsies. The time from injury to operation in both groups were 2 to 14 days. For patients in the MIPO group, fractures were closely reduced and fixated with an anterior placed plate inserted through two small incisions made at the anterior side of arm, away from fracture sites. The radial nerves were not exposed. For patients in the ORPO group, fractures were exposed, reduced, and fixated with an anterolateral or a posterior positioned plate after careful dissection and protection of radial nerve through an anterolateral or a posterior approach. The operation time, the occurrence of iatrogenic radial nerve palsy and the bone heal ing time were recorded. The functions of the affected shouldersand elbows were evaluated with UCLA end-result score and Mayo elbow perform index (MEPI), respectively. Results All the wounds in both groups healed primarily. There was no iatrogenic radial nerve palsies in the MIPO group after surgery; however, 5 cases of transient iatrogenic radial nerve palsies were identified in the ORPO group after surgery, and the function of radial nerve recovered in these cases at the last follow-up. Eighteen cases were followed up 14-44 months (mean 25.44 months) in MIPO group, and 19 cases were followed up 13-48 months (mean 32.11 months) in ORPO group. The mean bone heal ing time was 17.06 (12-32) weeks in MIPO group and 16.11 (8-58) weeks in ORPO group, showing no significant difference between two groups (P gt; 0.05). There was no nonunion and hardware failure in both groups. The mean forward flexion of the shoulder was 166.94° (150-170°) in MIPO group and 164.74° (130-170°) in ORPO group. The mean UCLA shoulder score was 34.78 (33-35) points in MIPO group and 34.42 (30-35) points in ORPO group. The mean range of motion of the elbow in MIPO and ORPO groups was 133.33° (120-140°) and 136.7° (120-140°), respectively. The MEPI in these two groups was 99.44 (90-100) and 99.74 (95-100) points, respectively. There was no statistically significant difference between two groups in all indexes mentioned above. Conclusion The good results could be obtained when ORPO and MIPO technique are appl ied to treat mid-distal humeral shaft fractures. MIPO technique has advantages to not expose the radial nerve and to decrease the occurrence of iatrogenic radial nerve palsies.
Objective To evaluate the security and effectiveness of minimal invasive fixation with fluoroscopybased navigation in the management of pelvic fractures. Methods From April 2007 to June 2008, 22 patients with pelvic fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system after closed reduction. There were 13 males and 9 females, aged 21-65 years old. Fractures were caused by traffic accident in 17 cases, andfall ing from height in 5 cases. According to AO classification, there were 2 cases of A2.2 type, 2 cases of A2.3 type, 7 cases of B1.2 type, 3 cases of B2.2 type, 1 case of B3.3 type, 2 cases of C1.2 type, 3 cases of C1.3 type, and 2 cases of C2.3 type. The interval from injury to hospital ization was 4 hours to 3 days (mean 1.2 days). After 3-13 days of skeletal traction through tibial tubercle, the operation was performed. Results Totally 42 screws were inserted. The average time for operation was 20.4 minutes per screw. Forty-one screws were inserted correctly with a successful insertion rate of 97.6%, only 1 hollow screw was reinserted for deviation. No incision problem and implant failure occurred. All 22 patients were followed up 7 to 21 months with an average of 14.5 months. At last follow-up, fracture union was achieved in all patients with satisfactory screw fixation. According to Majeed functional scoring, the results were excellent in 18 cases and good in 4 cases, with an excellent and good rate of 100%. Conclusion The minimal invasive fixation with fluoroscopy-based navigation makes the surgery for the pelvic fracture more precise and time-saving, and improves cl inical results without an increasing rate of compl ications.
To explore the possibil ity of treating mid-distal humeral shaft fractures associated with radial nerve palsies with minimal invasive plating osteosynthesis (MIPO) techniques. Methods From April 2003 to October 2006, 10 patients with mid-distal humeral shaft fractures associated with radial nerve palsies were treated. All patients were male, aged 19-58 years. According to AO/ASIF classification, there were 4 cases of B1 type, 2 cases of B3 type, 1 case of A2 type, 1 caseof B2 type, 1 case of C3 type and 1 case of A3 type. A straight 4.5 mm dynamic compression plate was placed on the anterior aspect of humerus through two small incisions located on the anterior side of proximal and distal part of the arm. The radial nerve exploration was performed through a lateral small incision made on the fracture site. The fractures were then reduced by manual manipulation and the plate was fixated to the main fragments with 3 screws in each end of the plate. The postoperative compl ications, the bone heal ing time, and the recovery time of the radial nerve functions were recorded. The functions of the affected shoulder and elbow were assessed with UCLA and Mayo elbow performance score system respectively. Results All incision healed by first intention. Ten patients were followed up 9-36 months with an average of 15.7 months. The X-ray films showed that the union of fractures was achieved 12-16 weeks (13.6 weeks on average). The function of the radial nerves recovered completely 12-36 weeks (17.8 weeks on average) in 9 patients. The abductions of the affected shoulder were 150-170° (165° on average). The ROM of the elbows were 130-140° (135.5° on average). According to the UCLA shoulder scoring system, 9 patients achieved the excellent result and 1 patient achieved the good result. All the patients had the excellent results according to Mayo elbow performance score system. Conclusion The mid-distal humeral shaft fractures associated with radial nervepalsies can be treated with MIPO technique and the good results can be obtained.
ObjectiveTo evaluate clinical outcomes of de-airing technique in minimally invasive cardiac surgery (MICS). MethodsFifty-six patients undergoing MICS in Zhongshan Hospital of Fudan University between June 2011 and June 2013 were recruited as a MICS group, including 31 male and 25 female patients with their age of 33-71 (57.3±7.2)years. Fifty-six patients who underwent mitral valvuloplasty via routine median sternotomy during the same period were recruited as the control group, including 27 male and 29 female patients with their age of 51-69 (53.7±6.8)years. Postoperative residual air in the heart, abnormal ECG findings, time to recovery of consciousness, cognitive function and neurological complications were compared between the 2 groups. ResultsThere were 69.6% patients with mild residual air and 30.4% patients with moderate residual air in the heart of MICS group, and 73.2% patients with mild residual air and 26.8% patients with moderate residual air in the heart of the control group (P > 0.05). There was no statistical difference in the incidence of abnormal ECG findings between the 2 groups (32.1% vs. 26.8%, P > 0.05). Patients with better, good and bad postoperative cognitive function accounted for 85.7%, 12.5% and 1.8% in MICS group respectively, and 78.6%, 19.6% and 1.8% in the control group respectively (P > 0.05). There was no statistical difference in the incidence of neurological complications between the 2 groups (1.8% vs. 1.8%, P > 0.05). ConclusionWith appropriate de-airing techniques, postoperative incidence of air embolism of MICS is comparable with that of conventional cardiac surgery via median sternotomy, and the risk of air embolism of MICS is not higher.
ObjectiveTo explore the effectiveness and safety of Mei mini maze procedure for atrial fibrillation (AF). MethodsWe analyzed the clinical data of 207 patients with 111 males, 96 females at 58.9±14.8 years in our hospital between October 2010 and February 2014. Among them, 98 patients were with paroxysmal AF and 109 patients were with persistent AF. The procedure was performed through three ports on left chest wall. Radiofrequency ablation procedures of AF included pulmonary veins isolation and ablations of the roof and posterior wall of left atrium, which were achieved by bipolar radiofrequency ablation. Ganglionic plexus ablation was made by the ablation pen. Left atrial appendage was excluded. ResultsTime of the procedures was 112.4±32.5 minutes. No conversion to sternotomy or pacemaker implantation occurred and no patients died. The hospital stay was 7.2±3.1days. The mean follow-up time was 24.2±8.9 months. A total of 187 (90.3%) patients were in sinus rhythm. And 20 patients could not maintain sinus rhythm. Stroke, thrombus in the left atrium and stenosis of pulmonary vein were not found after their procedures. ConclusionMei mini maze procedure is safe and presents optimistic outcomes for the atrial fibrillation.
ObjectiveTo observe the efficiency of endovenous laser therapy combined with planning sucking operation in the treatment of great saphenous varicose veins. MethodsTotally 48 patients (60 limbs) were treated from May 2011 to May 2014 in general surgery department of our hospital. The main trunk of great saphenous vein was ablated by endovenous laser treatment; and the varicose veins in calf were resected by planning sucking operation. ResultsAll 48 patients (60 limbs) were cured without recurrent during 6-36 months followed-up. The operative time of each side was 18-43 min, the average operative time was 22.6 min; with 1-3 skin incisions. Hospital stay was 5-8 d, the average hospitalization time was 6.7 d. After operation, the varicose veins and the felling of swelling were disappeared, the pigmentation was reduced or disappeared. Local skin numbness showed in 6 cases and recovered in 3-7 months after operation. Felling of burns appeared in 2 cases, and was healed after treatment. Ankle swelling presented in 5 cases, and released in 6-13 d with related treatment. Different degree of subcutaneous bruising appeared without any hematoma, and recovered in 2-4 weeks. Two cases were lost during the followed-up. ConclusionsEndovenous laser therapy combined with planning sucking operation is safe and effective in the treatment of great saphenous varicose. It is worthy of promotion with minimum damage, less pain, fast recovery, no scars, shorter operative time, and shorter hospital stay.
ObjectiveTo investigate the safety and effectiveness of minimally invasive coronary artery bypass grafting (MICABG) through comparing the perioperative clinical effects of conventional surgery and MICABG.MethodsA total of 543 patients in the single medical group of Beijing Anzhen Hospital who underwent beating coronary artery bypass grafting from January 2017 to September 2020 were collected, including 161 patients receiving MICABG (a minimally invasive group, 143 males and 18 females, aged 60.08±9.21 years), 382 patients receiving median thoracotomy (a conventional group, 284 males and 98 females, aged 61.68±8.81 years). The propensity score was used to match 143 patients in each of the two groups, and the perioperative data of the two groups were summarized and analyzed.ResultsThere was no death, perioperative myocardial infarction or stroke in the minimally invasive group. Compared with the conventional group, the minimally invasive group had longer operation time (296.36±89.4 min vs. 217.80±50.63 min, P=0.000), less number of bypass grafts (2.86±1.03 vs. 3.17±0.78, P=0.005), shorter postoperative hospital stay (6.29±1.46 d vs. 6.78±2.61 d, P=0.031), less drainage on postoperative day 1 (339.57±180.63 mL vs. 441.92±262.63 mL, P=0.001) and lower usage rate of inotropic drugs (9.09% vs. 26.57%, P=0.001). There was no statistical difference between the two groups in postoperative ICU stay ventilator assistance time, blood transfusion rate, secondary thoracotomy rate, or use of mechanical equipment.ConclusionReasonable clinical strategies can ensure the satisfactory overall safety of MICABG. In addition, it has the advantages of shorter postoperative hospital stay, less bleeding and smaller dosage of inotropic drugs.