west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Multi-slice spiral CT" 6 results
  • Clinical Application of Multi-Slice Spiral CT in Portal Vein Imaging

    Objective To study the clinical significance of multi-slice spiral CT in portal vein imaging. Methods One hundred and thirty seven cases underwent enhanced scan with GE Light SpeedQX/i4 CT scanner were collected, including 41 cases of liver cancer, 20 cases of hepatic cirrhosis, 21 cases of cavernous hemangioma of liver, 9 cases of hepatic abscess, 6 cases of carcinoma of gallbladder, 14 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 5 cases in normal. The results of portal vein images were reconstructed with three-dimensional software and analyzed. Results In 109 cases, portal vein, cranial mesenteric vein, and splenic vein were demonstrated successfully in the stage of portal vein: volume rendering images were clear in 84 cases, and maximum intensity projection images and multiplanar reconstruction images were clear in 109 cases. Forty-five cases of portal hypertension, 18 cases of opened collateral circulation, 15 cases of portal vein tumor thrombus, 1 case of splenic vein tumor thrombus, and 6 cases of large cavernous hemangioma were demonstrated successfully. Conclusion The portal vein imaging with multi-slice spiral CT can show the dissection and lesions of portal vein and its branches clearly, and can provide the clinical evidence for clinicians to formulate a treatment plan correctly.

    Release date:2016-09-08 10:49 Export PDF Favorites Scan
  • FABRICATION AND APPLICATION IN VITRO OF PEDICLE GUIDE DEVICE FOR PEDICLE SCREWS INSERTION

    Objective To evaluate the accuracy of pedicle guide device for the placement of the pedicle screws. Methods Pedicle guide device was designed and made for the anatomical trait of pedicle. The 3-Danatomical data of the thoracic pedicles were measured by multislice spiral CT in two embalmed human cadaveric thoracic pedicles spine(T1 -T10). Depending on transverse section angle(TSA) and sagittal section angle(SSA) of pedicle axis, the degree of horizontal dial and sagittal dial were adjusted in the guide device. The screws wereinserted bilaterally in the thoracic pedicles by using the device. After pulling the screws out, the pathways were filled with contrast media. The TSA and SSA of developed pathways were measured. Results Analysis of the difference between pedicle axis and developed pathway was of no statistical significance(P>0.05). Conclusion The guide device could be easilyoperated and guarantee high accuracy of the pathways of screws and the incidence of pedicle penetration could be significantly reduced.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Evaluation of Multi-Slice Spiral CT for The Papillary Thyroid Carcinoma

    Objective To explore the manifestations and features of multi-slice spiral CT (MSCT) in the diagnosisof papillary thyroid carcinoma (PTC). Methods Preoperative MSCT data of 35 cases of PTC proved by operation and pathology in our hospital form May. to Jun. in 2013 were observed retrospectively, to analyze the manifestations and characteristics of MSCT for it. Results Of 35 patients with PTC, MSCT totally showed 48 lesions, 68.6% (24/35) of patients with single lesion, 31.4% (11/35) of patients with 2-3 lesions, and 62.9% (22/35) of patients with lymph node metastasis. Of the 48 lesions, 29.2% (14/48) of lesions located in the left lobe, 70.8% (34/48) of lesions located in the right lobe;the lesions’ maximum diameter were 0.4-5.8cm, with the average maximum diameter of 1.3cm. There were 39.6% (19/48) of lesions with uneven density, 25.0% (12/48) of lesions with irregular shape, 47.9% (23/48) of lesions with blurred edges, 18.8% (9/48) of lesions had papillary enhanced tumor nodules, 10.4% (5/48) of lesions had peritumoral incomplete enhanced ring sign, 22.9% (11/48) of lesions invaded surrounding tissue or organs. There were 35.4% (17/48) of lesions had calcification, in which 76.4% (13/17) of lesions were fine granular calcification, 11.8% (2/17) of lesions were mixed calcification, and 11.8% (2/17) of lesions were coarse calcification. Conclusion MSCT manifestations of PTC have certain characteristics, which can provide imaging basis for clinical treatment options.

    Release date:2016-09-08 10:35 Export PDF Favorites Scan
  • Diagnostic Value of MSCT and MRI for Stasis Cirrhosis

    Objective To investigate multi-slice spiral CT (MSCT) and MRI features of stasis cirrhosis and the diagnostic value of MSCT and MRI. Methods MSCT and MRI findings of 35 patients with stasis cirrhosis were studied. The size of liver and spleen, the diameter of hepatic vein (HV), enhancement pattern of liver parenchyma, contrast medium reflux in inferior vena cava (IVC) and (or) HV, ascites, number of varices and correlated abnormalities were reviewed. Results The volume index of liver and spleen of 35 patients was 4434.95 cm3 and 621.92 cm3 respectively. The mean diameter of HV of 27 patients (77.1%) was 3.61 cm and HV of other 8 patients (22.9%) were too small to show. Number of patients showed waves of borderline, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, varices and ascites was 5 (14.3%), 29 (82.9%), 20 (57.1%), 16 (45.7%), and 6 (17.1%), respectively. Correlated abnormalities included cardiac enlargement 〔4 cases (11.4%)〕, pericardium thickening 〔11 cases (31.4%)〕, and pericardial effusion 〔2 cases (5.7%)〕. Conclusions Stasis cirrhosis mainly demonstrate liver enlargement, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, and slight portal hypertension. MSCT and MRI play invaluable roles in diagnosis, differential diagnosis and etiological diagnosis of stasis cirrhosis.

    Release date:2016-09-08 11:04 Export PDF Favorites Scan
  • The Diagnostic Value of Multi-slice Spiral CT for Bronchial Mucoid Impaction in Early Central-type Carcinoma of Lung

    ObjectiveTo discuss the diagnostic value of multi-slice spiral CT for bronchial mucoid impaction in early central-type carcinoma of lung. MethodsWe used multi-planar reformat, maximum intensity projection and minimum intensity projection to observe the characteristics of 15 patients with bronchial mucoid impaction in early central-type carcinoma of lung treated between March 2010 and October 2013. The characteristics included location, shape and enhanced performance of the tumor and the bronchial mucoid impaction. All the cases were confi rmed by operation or pathology. ResultsAmong the 15 cases, 12 were squamous cell carcinoma and 3 adenocarcinoma; 8 occurred on the right and 7 on the left. All the tumors showed equal density and were enhanced moderately. Bronchial mucoid impaction showed low density, no enhancement, accompanied bronchiectasis and occurred in bronchi which were far from the tumor, and there were 9 cases of strip, 5 of fabrication, and 1 of nodositas or cystic carcinoma. ConclusionThe location and shape of tumor and bronchial mucoid impaction are displayed clearly by multi-slice spiral CT and enhancement scanning can differentiate tumor from bronchial mucoid impaction. Multi-slice spiral CT has important diagnostic value in bronchial mucoid impaction of primary lung cancer in its early stage.

    Release date: Export PDF Favorites Scan
  • EVALUATION OF MULTI-SLICE SPIRAL CT SCAN AND IMAGE RECONSTRUCTION TECHNOLOGY IN ESTIMATING COSTAL CARTILAGE VOLUME

    ObjectiveTo investigate the accuracy of multi-slice spiral CT (MSCT) scan and image reconstruction technology for measuring morphological parameters of costal cartilages and to evaluate the volume of costal cartilages. MethodsBetween March and August 2013, 75 patients with congenital microtia and scheduled for auricle reconstruction were included in the study. Of 75 patients, there were 49 males and 26 females with a mean age of 8 years and 5 months (range, 5 years and 7 months to 32 years and 7 months) and a mean weight of 29.5 kg (range, 21-82 kg). A Philips Brilliance 64 MSCT machine was used to scan 1st-12th costal cartilages with the parameters based on the age and weight of the patients. All the data were transported to the workstation for reconstructing the image of the costal cartilages with the technique of maximum intensity projection (MIP) and volume rendering technique (VRT). Then the morphologies of costal cartilages were observed through the images on VRT; the width of the costal cartilaginous ends close to ribs (W) and the length of the total cartilage (L) were measured and compared with their counterparts (W' and L') after the costal cartilages were harvested during the processes of auricle reconstructions to analyze consistency between these two sets of data. ResultsThe morphologies of ribs and costal cartilages shown on VRT image got fine sharpness, verisimilitude, and stereoscopic impressions. A total of 192 costal cartilages were examined. The results showed that the widths of the costal cartilaginous ends close to ribs (W) was (9.69±1.67) mm, and W' was (9.73±1.64) mm, showing no significant difference between W and W' (t=-1.800, P=0.073), and interclass correlation coefficient (ICC) test showed Cronbach's α=0.993. The length of the total cartilage (L) was (83.03±23.86) mm, and L' was (81.83±16.43) mm, showing no significant difference between L and L' (t=1.367, P=0.173), and ICC test showed Cronbach's α=0.904. Linear-regression analysis showed L=1.28×L'-21.93 (R2=0.780, F=673.427, P=0.000). The results suggested there was a good consistency between these two sets of data. ConclusionScanning costal cartilages with appropriate parameters and reconstructing the cartilaginous image with MIP is an effective method to measure the width and length of costal cartilage and to estimate costal cartilage volume, which can provide accurate reference for plastic surgery together with reading the morphology from the image on VRT.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content