west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Off-pump coronary artery bypass grafting" 26 results
  • Impact of Edaravone on Serum Reactive Oxygen Species during Perioperative Period of Off-pump Coronary Artery Bypass Grafting: A Randomized Controlled Trial

    Objective To investigate the impact of edaravone on serum reactive oxygen species during the perioperative period of off-pump coronary artery bypass grafting (OPCAB). Methods A total of 40 patients who underwent selective OPCAB in the First Hospital of Hebei Medical University between June 2011 and November 2012 were prospectively enrolled in this study. All the patients were randomly divided into a trial group and a control group by a random digitaltable method with 20 patients in each group. There were 13 males and 7 females in the trial group with their age of 40-67(51.8±11.5) years, and 9 males and 11 females in the control group with their age of 42-70 (53.5±13.1) years. Afteranesthesia induction, patients in the trial group received continuous intravenous infusion of edaravone 60 mg (diluted in 100 ml saline), while patients in the control group received continuous intravenous infusion of saline 100 ml, both of whichwere finished within 30 minutes. Venous blood samples were taken 24 hours preoperatively (T1), 1 hour after skin incision(T2), at the end of the surgery (T3) and 24 hours postoperatively (T4) to examine the concentration of superoxide dismutase(SOD) and malondialdehyde (MDA). The data of the two groups were compared. Results All the patients successfully underwent their surgery and were included in the analysis. At the T2, T3 and T4 time point, SOD concentration was 80.3±21.3 U/ml, 78.5±17.4 U/ml and 81.4±17.5 U/ml, and MDA concentration was 10.2±1.8 nmol/ml, 11.3±1.9 nmol/ml,14.8±2.1 nmol/ml respectively in the control group;SOD concentration was 92.8±18.4 U/ml,90.0±18.1 U/ml,and 88.7±18.7 U/ml,and MDA concentration was 7.2±1.7 nmol/ml,8.2±1.2 nmol/ml,10.2±1.3 nmol/ml respectively in the trial group. At each above time point, SOD activity was significantly higher in the trial group than the control group (F=2.90,P=0.003;F=2.80,P=0.003;F=2.80,P=0.001), and MDA concentration was significantly lower in the trial group than the control group (F=2.79,P=0.001;F=2.80,P=0.001;F=2.90,P=0.000). Conclusion Edaravone can decrease serum reactive oxygen species caused by OPCAB and reduce myocardial injury.

    Release date:2016-08-30 05:45 Export PDF Favorites Scan
  • Application of Intra-aortic Balloon Pump for High-risk Patients before Off-pump Coronary Artery Bypass Grafting

    Abstract: Objective To analyze clinical outcomes of intra-aortic balloon pump (IABP) application for high-risk  patients before undergoing off-pump coronary artery bypass grafting (OPCAB), and summarize our experience and weaning indications of IABP. Methods We retrospectively analyzed clinical data of 102 high-risk patients with coronary artery disease who underwent IABP implantation before OPCAB from January 2008 to July 2011 in Zhongshan Hospital of Fudan University. There were 71 male patients and 31 female patients with their average age of 63.0±8.2 years in this IABP group. We also chose another 100 patients without IABP implantation before undergoing OPCAB as the control group, including 55 male patients and 45 female patients with their average age of 64.1±9.5 years. Postoperative systolic arterial blood pressure (SABP), mean arterial blood pressure (MABP), mechanical ventilation time, length of intensive care unit(ICU) stay, morbidity, duration of IABP treatment and in-hospital mortality of two groups were compared. Left ventricular  ejection fraction (LVEF) was evaluated with echocardiography 3 months after surgery. Results Postoperative SABP (95.3±12.2 mm Hg vs. 80.1±11.7 mm Hg;t=8.440, P=0.000) and MABP (78.9±13.5 mm Hg vs. 52.3±15.1 mm Hg; t=12.410, P=0.000) of the IABP group were significantly higher than those of the control group. Mechanical ventilation time, length of ICU stay and duration of inotropic support of the IABP group were significantly shorter than those of the control group. The incidence of ventricular arrhythmia, low cardiac output syndrome, perioperative myocardial infarction and dialysis-requiring acute kidney failure of the IABP group were significantly lower than those of the control group. In-hospital mortality of the IABP group was significantly lower than that of the control group [5.9% (6/102) vs. 17.0% (17/100), χ 2 =6.180, P=0.020]. Ninety-six patients in the IABP group and 83 patients in the control group were followed up for 3 months. Three months after surgery, echocardiography showed that LVEF of the IABP group was significantly higher than that of the control group(45.3%±12.0% vs. 39.1%±8.2%, t=3.950, P=0.000). Conclusion Preoperative prophylactic IABP implantation and optimal timing of weaning from IABP support can not only significantly reduce surgical risk and improve surgical outcomes and postoperative recovery of high-risk patients undergoing OPCAB, but also considerably ameliorate patient heart function and reduce perioperative morbidity and mortality.

    Release date:2016-08-30 05:28 Export PDF Favorites Scan
  • Preoperative Oral Amiodarone for the Prevention of Atrial Fibrillation after Coronary Artery Bypass Grafting in Patients Older Than 70 Years

    Objective To evaluate the efficacy of preoperative low-dose oral amiodarone for the prevention of atrial fibrillation (AF) after off-pump coronary artery bypass grafting (OPCAB) in patients older than 70 years. Methods A total of 156 patients older than 70 years who underwent OPCAB in Qingdao Fuwai Cardiovascular Disease Hospital from January 2011 to June 2012 were included in this prospective,double-blind and placebo controlled study. Preoperatively,all the 156 patients were randomly divided into amiodarone group and control group. In the amiodarone group,there were 80 patients including 38 male and 42 female patients who were given oral amiodarone (trade name: Cordarone) 200 mg,three times a day,3-5 days before surgery,and amiodarone was stopped on the OPCAB day and postoperatively. Preoperative duration of amiodarone intake was 4.0±1.2 days,and total amiodarone dosage was 2.6±0.5 g. In the control group,there were 76 patients including 35 male and 41 female patients who were given oral placebo as the same medication schedule,and preoperative duration of placebo intake was 4.0±1.4 days. Operation time,graft number,postoperative AF incidence,AF duration,hospital stay and readmission rate for cardiovascular events within 6 postoperative months were compared between the two groups. Results There was no in-hospital death in either group. There was no statistical difference in graft number,operation time,AF duration of patients who had postoperative AF,or postoperative hospital stay between the two groups. Postoperative AF incidence of the amiodarone group was significantly lower than that of the control group [18.7% (15/80) vs. 34.2% (26/76),P=0.028]. Seventy-three patients in the amiodarone group (91.3%) and 66 patients in the control group (86.8%) were followed up for 8-24 months. During follow-up,2 patients in the amiodarone group died of acute myocardial infarction and cerebral hemorrhage respectively. There was no statistical difference in readmission rate for cardiovascular events within 6 postoperative months between the 2 groups [6.8% (5/73) vs. 6.1% (4/66),P=0.860] .Conclusion Preoperative low-dose oral amiodarone can significantly reduce the incidence of postoperative AF in patients older than 70 years undergoing OPCAB.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • Off-pump Surgical Therapy for Mild-to Moderate-Ischemic Mitral Regurgitation Using a Self-designed Device

    Abstract: Objective To evaluate the effect of a surgical method for treating mild- to moderate-ischemic mitral regurgitation(IMR) using a self-designed device during off-pump coronary artery bypass grafting(OPCAB). Methods From September 2009 to August 2011, six patients(4 males, 2 females; age was 52-73 years) with mild- to moderate-IMR underwent OPCAB and concomitant mitral valvuloplasty using a self-designed device in Beijing An Zhen Hospital. Their degree of IMR, anteroposterior diameter of mitral annulus, left ventricular long-axis diameter, left ventricular short-axis diameter and left ventricular spherical index(left ventricular short-axis diameter/left ventricular long -axis diameter)were measured using transesophageal Doppler echocardiography before and after mitral valvuloplasty. Their mean aorta pressure, mean pulmonary artery pressure and central venous pressure were also measured via Swan-Ganz catheter before and after mitral valvuloplasty. Perioperative cardiac function indexes were compared. Results There was no in-hospital death. IMR of all patients disappeared postoperatively. After mitral valvuloplasty their anteroposterior diameter of mitral annulus(3.43±0.08 cm vs.3.68±0.08 cm;t=5.430, P=0.001), left ventricular short-axis diameter(4.80±0.21 cm vs.5.53±0.11 cm;t=7.530, P=0.001)and left ventricular spherical index(0.64±0.02 vs.0.74±0.01;t=11.110, P=0.002)significantly decreased than those before mitral valvuloplasty . But their left ventricular long-axis diameter and hemodynamic indexes did not change significantly after mitral valvuloplasty. All the six patients were followed up at the out-patient department 3 months postoperatively without autonomous symptoms. Their heart function improved to I class(New York Heart Association). Echocardiography showed 4 patients without IMR and 2 patients with trace of minimalIMR. Conclusion Off-pump surgical therapy for mild- to moderate- IMR during OPCAB can help the patients reverseremodeling of the left ventricle, avoid the risks of cardiopulmonary bypass and improve cardiac function with good short-term effects. This method may be a good choice for treating patients with IMR.

    Release date:2016-08-30 05:50 Export PDF Favorites Scan
  • Clinical Analysis of Redo Coronary Artery Bypass Grafting

    Abstract: Objective?To summarize our experience of redo coronary artery bypass grafting(CABG) and explore appropriate redo CABG strategy for Chinese patients. Methods We retrospectively analyzed clinical data of 27 patients who underwent redo CABG in People’s Hospital of Peking University from January 2000 to January 2010. There were 15 male patients and 12 female patients with their age of 41-84 (63±8) years. The mean time between the first CABG and the redo CABG was 45 (4-168) months. Preoperatively all the patients had unstable angina pectoris. Twenty-one patients were in New York Heart Association (NYHA) functional classⅠ-Ⅱ, and 6 patients were in NYHA functional classⅢ-Ⅳ. Preoperatively, their left ventricular end-diastolic dimension (LVEDD) was 41-69 (51.0±0.7) mm, and their left ventricular ejection fraction (LVEF) was 32%-78% (58%±12%). At the time of redo CABG for the 27 patients, there were 6 new coronary artery lesions, 7 left internal mammary artery (LIMA) lesions, 3 radial artery lesions (including 1 proximal anastomosis lesion alone) and 49 saphenous vein graft (SVG) lesions (including 3 proximal lesions alone and 3 distal lesions alone).?Results?The surgical approach of redo CABG included median sternotomy in 18 patients, left lateral thoracotomy in 8 patients, upper midline abdomen and subxiphoid incision in 1 patient. Off-pump coronary artery bypass grafting (OPCAB) surgery was performed in 25 patients, but intra-operatively 2 patients underwent conversion to CABG under cardiopulmonary bypass. A total of 65 distal anastomoses and 41 proximal anastomoses were performed during redo CABG. A total of 10 LIMA, 3 right internal mammary artery (RIMA), 16 left radial artery, 2 right radial artery and 17 SVG were used in redo CABG . There were 1-4 (2.4±0.8) distal anastomoses for each patients. The operation time was 170-530 (304±86)min. Postoperative transfusion was 0-10 (4.3±3.5) U packed red blood cells and 0-1 600 (685±549) ml fresh frozen plasma for each patient. Postoperative mechanical ventilation time was 6-156 (24±32) h and postoperative hospital stay was 7-35 (14±6) d . There was no in-hospital death. All the patients were discharged without any angina symptoms. A total of 26 patients were followed up and 1 patient was lost with the mean follow-up time of 80 (13-133) months. During follow-up, 16 patients were alive without angina symptoms, 4 patients died, and 6 patients had recurrent angina symptoms or heart failure. Conclusions OPCAB is an effective surgical strategy of redo CABG, but cardiopulmonary bypass should also be prepared. Arterial graft should be use as long as possible in redo CABG and the surgical strategy should be individualized.

    Release date:2016-08-30 05:51 Export PDF Favorites Scan
  • Comparison Between Midterm Patency of Sequential and Individual Saphenous Vein Grafts after Off-pump Coronary Artery Bypass Grafting

    Abstract: Objective To compare the midterm patency rates of individual and sequential saphenous vein grafts (SVG) as coronary bypass conduits of offpump coronary artery bypass grafting (OPCAB) and evaluate the impact of the grafting techniques (individual or sequential grafts) on the graft patencyafter OPCAB. Methods The clinical data of 398 patients in General Hospital of the People’s Liberation Army receiving OPCAB with individual and sequential grafts from June 2005 to March 2009 were retrospectively analyzed. There were 301 males and 97 females with their age ranged from 53 to 82 years (63.6±10.3 years). A total of 714 distal coronary anastomoses on 448 SVG were assessed by using 64multislice computed tomography (64MSCTA) at an average of 19.8±23.6 months (3 months to 5 years) after OPCAB procedure. The blood flow of grafts in the proximal segment of individual and sequential SVG and the patency rates of grafts and anastomoses were compared, and the effect of different locations on the patency rate of the anastomoses was analyzed. Results The mean blood flow in double SVG (37.11±16.70 ml/min vs. 25.15±14.24 ml/min, P0.042) and in triple SVG (37.56±19.58 ml/min vs. 25.15±14.24 ml/min, P=0.048) were both significantly higher than the flow in single SVG. The anastomoses on the sequential conduits had better patency (95.1% vs. 90.1%, P=0.013). The patency of sideto side anastomoses was better than that of endtoside anastomoses (97.0% vs. 93.1%, P=0.002) and that of the individual endtoside anastomoses (97.0% vs. 90.1%, P=0.041). There was no significant difference between distal anastomoses in sequential and those in single grafts (P=0.253). No significant difference was observed between the two methods in regard to the three major coronary systems (including the anterior descending branch, the right coronary artery, and the circumflex branch). However, anastomoses on sequential grafts had superior patency to those on individual grafts in the right coronary system (P=0.008). Conclusion The midterm patency of a sequential SVG conduit after OPCAB is excellent and generally superior to that of an individual one. The best runoff coronary artery should be placed at the distal end and the poor coronary vessels should be arranged in the middle of the grafts.

    Release date:2016-08-30 05:57 Export PDF Favorites Scan
  • The Use of Prostaglandin E1Dur ing Off-pump Coronary Artery Bypass Graf ting in Patien ts of Old Age

    Abstract:  Objective To invest igate the effect of p ro staglandin E1 (PGE1 ) during off-pump co ronary artery bypass graft ing (O PCAB ).  Methods  F rom O ct. 2005 to Dec. 2005, 40 consecut ive pat ients w ho underw ent O PCAB w ere random ly divided into two group s. The cont ro l group received convent ional t reatment w h ile the PGE1 group received cont inuous int ra2vena PGE1 infusion ( 5220 ngouml;k g?m in) fo r 24248 hours. The perioperat ivehemodynam ic indexes, including cardiac index (C I) , system ic vascular resistance ( SVR ) , pulmonary vascular resistance (PVR ) , and hematocrit (HCT ) , coagulation index (C I) , partial pressure of oxygen in artery (PaO 2 ) ,serum creat inine (Cr) and blood urea nitrogen (BUN ) were measured and compared.  Results Postoperative SVR and PVR decreased and C I increased significantly in the PGE1 group (P lt; 0. 05). Postoperative HCT decreased in the both group patients. Coagulation index decreased significantly on the operation day, but then increased in both groups on the next day after operation, with the increase in the PGE1 group significantly less than control group (P lt;0. 05). Postoperative serum Cr and BUN increased significantly in the both groups, especially in the control group (P lt; 0105).  Conclus ion PGE1 has potential beneficial effect on patients undergoing OPCAB.

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • Surgical Treatment for Patients with Diffused Coronary Artery Disease

    Objective To summarize the early outcomes and clinic al experience of off-pump coronary artery bypass grafting (off-pump CABG) afte r off-pump coronary endarterectomy (CE) for patients with diffused coronary art ery disease. Methods From May 2003 to November 2006,83 patients with diffu sed coronary artery disease underwent CE without cardiopulmonary bypass and off-pump CABG. There were 61 males and 22 females with age ranged from 55 to 80 ye ars (65±7 years). There were 7 patients in Canadian Cardiac Society(CCS) an gina classⅡ,20 patients in class Ⅲ,and 56 patients in class Ⅳ. 36(43.4%) pat ients had history of myocardial infarction. Coronary angiogram revealed th at 5 patients had double vessels disease, and other 78 patients had triple ves s els disease with 16 left main stem disease. The left ventricular ejection fract ion(LVEF) ranged from 25% to 65% (51%±16%). One hundred and ten endarter e ctomies were performed in 83 patients totally which included 67 in left anterior descending artery(LAD),9 in circumflex artery and 34 in right coronary artery . Twenty patients received onlay venous patch after CE in LAD and then grafte d by internal mammary artery (IMA) on the patch. There were 83 left IMA, 2 radia l arteries, others were great saphenous veins, the mean number of grafts was 3.9 ±1.2. Results There was no death in all patients. Intraoper ative graft flowmeter was used to check the flow in the grafts before chest cl osure. One hundred and one (92%) out of 110 grafts after CE showed a satisfactor y grafts flow(22±16ml/min) intraoperatively. Four patients had perioperative myocardial infarctions but none had hemodynamic changes. All patients discharged uneventfully. Seventyfive patients (90.4%) had 8 to 50 months followup with no angi na reoccurrence. Eight patients had coronary angiogram from 3 to 29 months af ter operation with all patent grafts to the CE coronaries. Conclusion Off-pump CABG with coronary endarterectomy is feasible and achieves surgical revascularization in patients with diffuse cor onary artery disease.

    Release date:2016-08-30 06:09 Export PDF Favorites Scan
  • Compare the Early Result of Total Arterial Revascularization with Traditional Coronary Artery Bypass Grafting

    Objective To assess the use of arterial revascularization and to compare the early outcomes with traditional coronary artery bypass grafting (CABG). Methods From January 1999 to January 2005, 123 patients (114 male, 9 females; age 52.2±10.1 years) underwent coronary artery surgery alone with disease of more than one coronary artery were considered for complete arterial revascularization (artery revascularization group). Internal mammary artery and radial artery was considered for artery grafts. At same period 115 patients (102 males, 13 females; age 60.3±9.1 years) underwent traditional revascularization using left internal mammary artery and veins (traditional group). The purpose was to compare the operative results between two groups. Results The patients in artery revascularization group were younger than that in traditional group, but there were more patients with three vessels disease in traditional group(54.5% vs. 86.1%, P=0.001). Off-pump CABG was choosed for more patients in artery revascularization group (26.0% vs. 57.4%, P=0.001). Patients in this group need more operative time if on-pump technique was used. The number of grafts were less in this group (2.6±0.7 vs. 3.4±0.9, P=0.001).There was no significant difference in hospital mortality and morbidity between two groups. Conclusion Proper patients using artery grafts appear to be safe in terms of in hospital mortality and morbidity.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • The Clinical Applie of Off-pump and On-pump Coronary Bypass Surgery Technique for Coronary Artery Bypass Grafting Re-operations

    Objective To compare the clinical early results of on-pump and off-pump coronary artery bypass grafting re-operations (re-CABG)and introduce our experience. Methods From April 2000 to June 2006, 21 cases with coronary artery diease of re-CABG were performed in this hospital. 10 patients received off-pump CABG (off-pump group), and 11 underwent CABG re-operations with cardiopulmonary bypass CABG(on-pump group). There were no significant difference regarding gender, age, weight, diabetes, hypertension, left ventricular end-diastolic dimension (LVEDD) and left ventricular ejection fraction (LVEF) between two groups before operation. On-pump CABG procedures were performed on hypothermia cardiopulmonary bypass. Standard methods were used to finish off-pump CABG. Flow meters were utilized to measure the flow of grafts in both groups. Results No one in off-pump group needed to conver to on-pump CABG. There was no operative or late mortality. The operation time, respiratory support time, the volume of chest tube drainage, blood transfusion and postoperative hospital stay were less in off-pump group than those in on-pump group after operation. Early death occurred in 1 patient in on-pump group. The number of distal anastomosis were more in on-pump group than that in off-pump group. Conclusions Both off-pump CABG and on-pump CABG can be applied to CABG re-operations and achieved similar completeness of revascularization, similar early surgical results.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content