west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "P100" 2 results
  • Contingent Negative Variation:A Brainwave Associated with Expectation

    The present study used the experimental patterns of Go/No Go and no motion contingent negative variation (CNV) task into the research in order to study whether the CNV can express the implication of expectation. Through comparing the CNV under different conditions, the data collected from experiment showed that the key to evoked CNV was close to the warning signal and command signal. Whether the command signal was related to the task would impact on the amplitude of the CNV. This characteristics responses to the subjects' expectation. On this basis, CNV can be used as the electrophysiological index for the reflection of expected value in the conditions of this experiment.

    Release date: Export PDF Favorites Scan
  • Exploration of porcine thyroidectomy via submaxillary approach using MP1000 robotic surgical system in porcine animal model

    ObjectiveTo investigate the safety and feasibility of domestic MP1000 robotic surgical system assisted thyroidectomy via submaxillary approach in porcine animal model. MethodThe thyroidectomy process assisted by the MP1000 robotic surgical system via submaxillary approach for a Bama pig in the 960th Hospital of the Joint Logistics Support Force was retrospectively analyzed. ResultsThe operation was performed as planned programme using the MP1000 robotic surgical system without opening, adding or lengthening the surgical incision. There was no mechanical problems during the MP1000 robotic surgical operation. The operative time was 53 min and the estimated intraoperative blood loss was 10 mL. There was no shaking of instruments and robotic arm during the operation, and the 3 surgical instruments cooperated skillfully, the establishment of surgical operation space successfully was completed, the thyroid blood vessels accurately and finely was dissected, and the separation, coagulation and cutting of blood vessels were smoothly completed. The recurrent laryngeal nerve and parathyroid gland were delicately dissected and protected. The carotid sheath, trachea, esophagus, and other important organs around the thyroid did not be damaged. The master-slave mapping frequency was high, and there was no delay sense during the operation. The lens resolution of MP1000 was 1 920×1 080, the surgical field of vision was clear, no visual field was defected and the visual field was stable and not shaking, light source front and intelligent adaptive temperature control system reduced the fogging of the lens, and the lens was scoured for 4 times during the operation. ConclusionAccording to the preliminary results of the experimental animal in this study, MP1000 robotic surgical system can successfully complete thyroidectomy via submaxillary approach in porcine animal model.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content