west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Prosthetic aseptic loosening" 1 results
  • EFFECTIVENESS OF ACETABULAR REVISION USING JUMBO CEMENTLESS CUPS

    Objective To investigate the effectiveness of acetabular revision using jumbo cementless cups. Methods Between May 1996 and May 2011, 35 patients (35 hips) underwent an acetabular revision with jumbo cementless cups, and the clinical data were retrospectively analyzed. There were 12 males and 23 females, with an average age of 64.8 years (range, 47-79 years). The time from hip arthroplaty to revision was 1-15 years (mean, 9.7 years). The causes for revision were aseptic loosening in 32 cases, femoral periprosthetic fracture (Vancouver type B3) in 2 cases, and low toxicity infection in 1 case. According to the classification of acetabular bony deficiencies of the American Association of Orthopedic Surgeon (AAOS), 6 cases were classified as type I, 9 cases as type II, and 20 cases as type III; according to the classification proposed by Paprosky, 5 cases were rated as type II A, 9 cases as type II B, 13 cases as type II C, and 8 cases as type III A. The primary hip arthroplasty cups had an outside diameter of 46-52 mm (mean, 49.6 mm), and the revision cups had an outside diameter of 56-68 mm (mean, 60.4 mm). Harris score was used for hip function evaluation, and X-ray films were taken for imaging evaluation. Results Healing of incision by first intention was obtained in all patients; without infection or neurovascular injury. Prosthetic dislocation was observed in 1 case at 20 days after operation, and was cured after expectant treatment. One patient died at 6 years after operation, and the other 34 patients were followed up 2-14 years (mean, 8.4 years). The Harris score was significantly increased from 46.4 ± 13.4 at preoperation to 90.4 ± 3.6 at last follow-up (t=18.76, P=0.00). The distance between acetabular rotation centre and teardrop line was significantly decreased, and the distance between acetabular rotation centre and lateral teardrop was significantly increased when compared with preoperative ones (P lt; 0.05). Only 1 patient received second revision for aseptic loosening after 10 years; no continuous radiolucent line, prosthetic dislocation, and osteolysis was found, and bony ingrowth was shown in the other patients. Conclusion Jumbo cementless cup for acetabular revision can achieve good effectiveness for having the advantages of simple operation, less bone grafts, and good recovery of the acetabular rotation centre.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content