west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Prosthetic heart valve" 4 results
  • Clinical Application of New(GK) Bileaflet Mechanical Heart Valve

    Objective To introduce a new type of bileaflet mechanical prosthetic heart valve (GK bileaflet valve)and evaluate clinically the early hemodynamic effect and short term follow-up after its replacement. Methods Sixty-one patients with heart valve diseases were operated upon. The mitral valve replacement was performed in 34 patients, aortic valve replacement in 16 patients and double valve replacement in 11 patients. A total of 72 GK bileaflet mechanical valves were implanted, 45 in mitral position, and 27 in aortic position. Blood consistency and hemodynamics were monitored. Follow-up was carried out routinely to check whether there were some valve-related complications. Results There was no early mortality (〈30 d). Only one patient died of trauma 2 months after the operation. Follow-up was 100% and extended 1 to 2. 5 years. Without valve-related complications all patients had lived for more than 1 to 2.5 years. In 98% (60/61) of survivors heart functional performance had improved to New York Heart Association class Ⅰ or Ⅱ . Conclusion Early clinical results and short term follow up demonstrate that GK bileaflet prosthetic heart valve exhibits excellent hemodynamic properties, satisfied blood consistency and a low incidence of valve-related complications. Midterm and long-term results should be observed further.

    Release date:2016-08-30 06:26 Export PDF Favorites Scan
  • Low-intensity Anticoagulation for Patients with Prosthetic Heart Valves in Northeast China: A Single-center Study

    ObjectiveTo explore optimal intensity of oral anticoagulation for patients with prosthetic heart valves in Northeast China. MethodsA total of 856 patients in Northeast China who underwent prosthetic heart valve replacement in the Department of Cardiovascular Surgery,Second Hospital of Jilin University from January 2005 to June 2013 were enrolled in this study. There were 406 male and 450 female patients with their age of 45.2±13.3 years. All the patients received low-intensity oral anticoagulation [international normalized ratio (INR) 1.5-2.2,aortic valve replacement (AVR):1.5-1.8,mitral valve replacement (MVR):1.8-2.2]. Patients were followed up after discharge,and the incidence of anticoagulation-related complications was summarized. ResultsThese patients were followed up for 1-78 (18.3±12.2) months,and the follow-up rate was 75.4%. Twelve patients (1.86%) had thromboembolic complications and 10 patients (1.55%) had hemorrhagic complications. Average warfarin dosage was 3.4±0.8 mg/day,and average INR was 1.94±0.54 during follow-up. ConclusionFor patients with prosthetic heart valves in Northeast China,low-intensity anticoagulation can produce satisfactory clinical outcomes to reduce the incidence of anticoagulation-related thromboembolic or hemorrhagic complications.

    Release date: Export PDF Favorites Scan
  • Reason Analysis and Prevention of Late Bioprosthetic Heart Valve Thrombosis

    ObjectiveTo analyze the reason and prevention of late bioprosthetic heart valve thrombosis (LBVT). MethodsBioprosthetic heart valves were implanted in 580 patients between January 2001 and July 2013 in Changhai Hospital, and only found one case of LBVT (0.2%). Reoperation was performed for a 67-year-old male patient 3 years after bioprosthetic aortic valve replacement due to severe aortic valve stenosis. Retrospectively analyzed the clinical data and reviewed the literature between January 1989 and December 2013 in Pubmed. ResultsNo risk factor for thrombosis was revealed in this patient. Pathology revealed valve thrombosis and collagen and elastic fibers fragmentation and disruption in valve leaflets. In literature review, 20 articles and 47 cases were brought in. The morbidity of LBVT was 0.2%-1.0%. At least 18 patients had high risk factors, and 15 of the 18 patients discontinued anticoagulation after 3 months. However, at least 10 patients had no high risk factors. Forty-four of the 47 patients received stented porcine valve replacement, only one patient received stented bovine pericardial valve replacement. ConclusionsLBVT is a rare but serious complication after bioprosthetic valve replacement, the causes of which include the feature of the patients and the bioprosthetic valves. Bovine pericardial valves could be superior to porcine valves in preventing LBVT. Postoperative long-time aspirin therapy is recommended for patients without high risk factors. Patients with any high risk factors should prolong anticoagulation.

    Release date: Export PDF Favorites Scan
  • The history of pulsatile flow experiment of prosthetic heart valve: The 70th anniversary of the application of prosthetic heart valves

    The pulsatile flow experiment can not only evaluate the preclinical safety and risk of prosthetic heart valve (PHV) but also play an important role in the computational model and fluid simulation, providing an experimental basis for the performance optimization of PHV. This paper mainly reviews the development and the latest progress of PHV pulsatile flow experiments and the characteristics of experimental pulse duplicator, and discuss the research direction of pulsatile flow experiments, expecting a further development in this field.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content