west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "QIAO Rui" 3 results
  • A comparative study on treatment of lumbar degenerative disease with osteoporosis by manual and robot-assisted cortical bone trajectory screws fixation

    ObjectiveTo compare the safety and accuracy of manual and robot-assisted cortical bone trajectory (CBT) screws fixation in the treatment of lumbar degenerative diseases with osteoporosis.MethodsThe clinical data of 58 cases of lumbar degenerative disease with osteoporosis treated by CBT screw fixation between February 2017 and February 2019 were analyzed retrospectively. Among them, 29 cases were fixed with CBT screws assisted by robot (group A), 29 cases were fixed with CBT screws by hand (group B). There was no significant difference between the two groups in terms of gender, age, body mass index, lesion type, T-value of bone mineral density, and operative segment (P>0.05), with comparability. The accuracy of implant was evaluated by Kaito’s grading method, and the invasion of CBT screw to the superior articular process was evaluated by Babu’s method.ResultsThe operation time and intraoperative blood loss in group A were significantly less than those in group B (t=−8.921, P=0.000; t=−14.101, P=0.000). One hundred and sixteen CBT screws were implanted in the two groups. At 3 days after operation, according to the Kaito’s grading method, the accuracy of implant in group A was 108 screws of grade 0, 6 of grade 1, and 2 of grade 2; and in group B was 86 screws of grade 0, 12 of grade 1, and 18 of grade 2; the difference was significant (Z=4.007, P=0.000). There were 114 accepted screws (98.3%) in group A and 98 (84.5%) in group B, the difference was significant (χ2=8.309, P=0.009). At 3 days after operation, according to Babu’s method, there were 85 screws in grade 0, 3 in grade 1, and 2 in grade 2 in group A; and in group B, there were 91 screws in grade 0, 16 in grade 1, 5 in grade 2, and 4 in grade 3; the difference was significant (Z=7.943, P=0.000). No serious injury of spinal cord, nerve, and blood vessel was found in the two groups. One patient in group A had delayed cerebrospinal fluid leakage, and 2 patients in group B had mild anemia. Both groups were followed up 10-14 months (mean, 11.6 months). The neurological symptoms were improved, and no screw loosening or fracture was found during the follow-up.ConclusionCompared with manual implantation of CBT screw, robot-assisted spinal implant has higher accuracy, lower incidence of invasion of superior articular process, and strong holding power of CBT screw, which can be applied to the treatment of lumbar degenerative diseases with osteoporosis.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Risk factors analysis of adjacent fractures after percutaneous vertebroplasty for osteoporotic vertebral compression fracture

    ObjectiveTo investigate the risk factors of adjacent fractures after percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fracture (OVCF).MethodsA total of 2 216 patients who received PVP due to symptomatic OVCF between January 2014 and January 2017 and met the selection criteria were selected as study subjects. The clinical data was collected, including gender, age, height, body mass, history of smoking and drinking, whether the combination of hypertension, diabetes, coronary arteriosclerosis, chronic obstructive pulmonary disease (COPD), bone mineral density, the number of fractured vertebrae, the amount of cement injected into single vertebra, the cement leakage, and whether regular exercise after operation, whether regular anti-osteoporosis treatment after operation. Firstly, single factor analysis was performed on the observed indicators to preliminarily screen the influencing factors of adjacent fractures after PVP. Then, logistic regression analysis was carried out for relevant indicators with statistical significance to screen risk factors.ResultsAll patients were followed up 12-24 months, with an average of 15.8 months. Among them, 227 patients (10.24%) had adjacent fractures. The univariate analysis showed that there were significant differences between the fracture group and non-fracture group in age, gender, preoperative bone density, history of smoking and drinking, COPD, the number of fractured vertebrae and the amount of bone cement injected into the single vertebra, as well as regular exercise after operation, regular anti-osteoporosis treatment after operation (P<0.05). Further multivariate logistic regression analysis showed that the elderly and female, history of smoking, irregular exercise after operation, irregular anti-osteoporosis treatment after operation, low preoperative bone density, large number of fractured vertebrae, and small amount of bone cement injected into the single vertebra were risk factors for adjacent fractures after PVP in OVCF patients (P<0.05).ConclusionThe risk of adjacent fractures after PVP increases in elderly, female patients with low preoperative bone mineral density, large number of fractured vertebrae, and insufficient bone cement injection. The patients need to quit smoking, regular exercise, and anti-osteoporosis treatment after PVP.

    Release date:2021-01-29 03:56 Export PDF Favorites Scan
  • Extensor digitorum communis split approach combined with loop-plate technique for treatment of ulnar coronoid fracture in terrible triad of elbow

    ObjectiveTo explore the effectivenesss of simple lateral extensor digitorum communis (EDC) split approach combined with loop-plate fixation in the treatment of ulnar coronoid fracture in terrible triad of elbow (TTE).MethodsThe clinical data of 60 patients with TTE who met the selection criteria between January 2015 and May 2018 were retrospectively analyzed. There were 48 males and 12 females, aged from 18 to 60 years (mean, 37.4 years). All the patients were closed fractures. Injury causes included fall injury in 28 cases, falling from height in 20 cases, and traffic accident injury in 12 cases. All patients had no vascular and nerve injury, and the time from injury to operation was 1-14 days, with an average of 4.8 days. The height and size of the fracture of the coronal process were measured by CT and accurate classifications were made. All the 60 patients were treated with simple lateral EDC split approach combined with loop-plate to fix the ulnar coronoid fracture; 20 patients of radial head fracture were fixed with hollow screw, 32 patients with mini-plate fixation, 8 patients with radial head prosthesis replacement; 16 patients with suture and 44 patients with suture anchor to reconstruct lateral collateral ligament complex; 10 patients with residual instability of elbow joint were fixed with hinge external fixator, and others were fixed with adjustable tension brace after operation. Postoperative imaging examination was performed to evaluate fracture healing and complications, such as loosening or breakage of internal fixator, osteoarthritis, and heterotopic ossification, etc. During follow-up, the range of motion (ROM) of the elbow joint was recorded, including elbow flexion, extension, and forearm pronation, supination. Mayo elbow function score system (MEPS) was used to evaluate elbow joint function at last follow-up.ResultsAll patients were followed up 16-24 months (mean, 20.2 months). All incisions healed by first intention after operation, and no complications such as vascular nerve injury, elbow joint instability, internal fixation failure, and infection occurred; the fracture healing time was 9-17 weeks (mean, 11.7 weeks). Four cases developed elbow stiffness after operation, and all underwent elbow joint lysis with internal fixator removal within 12-15 months after operation; 10 cases developed heterotopic ossification without special treatment. At last follow-up, the ROM of elbow flexion ranged from 85° to 135° (mean, 116°), the ROM of elbow extension ranged from 0° to 20° (mean, 11°), the ROM of forearm pronation ranged from 55° to 75° (mean, 70°), and the ROM of forearm supination ranged from 60° to 90° (mean, 83°). The MEPS score ranged from 55 to 100 (mean, 86.1); the effectiveness were excellent in 40 patients, good in 10 patients, fair in 6 patients, and poor in 4 patients, with an excellent and good rate of 83.3%.ConclusionThe simple lateral EDC split approach is fully exposed, and the loop-plate can fix the ulnar coronoid fractures firmly and stably, which can restore the stability of the elbow joint, and the effectiveness is satisfactory.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content