Objective To review the clinical operation methods of abdominal incisional hernia. Methods Classification, operation method and fellow-up of 78 patients with abdominal incisional hernia were retrospectively analyzed. Results The average time of fellow-up was 26 months. Nineteen cases were repaired with simple suture with 3 cases (15.8%) recurrence, 57 cases were repaired with man-made material with 2 case (3.4%) recurrence. Conclusions Individual operation method should be chosen according to body condition, classification of the size of abdominal loss and abdominal hypertension. It is an effective method to repair the hernia of abdominal incision with man-made material.