west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "SUN Jiahao" 2 results
  • Effectiveness analysis of revision surgery after total hip arthroplasty assisted by artificial intelligence preoperative planning system

    Objective To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (−1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation (P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation (t=−7.269, P<0.001). Conclusion AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.

    Release date: Export PDF Favorites Scan
  • Study on effectiveness of antibiotics guided by metagenomic next-generation sequencing to control infection after total knee arthroplasty

    ObjectiveTo explore the clinical value of metagenomic next-generation sequencing (mNGS) in diagnosis and treatment of periprosthetic joint infection (PJI) after total knee arthroplasty (TKA). MethodsBetween April 2020 and March 2023, 10 patients with PJI after TKA were admitted. There were 3 males and 7 females with an average age of 69.9 years (range, 44-83 years). Infection occurred after 8-35 months of TKA (mean, 19.5 months). The duration of infection ranged from 16 to 128 days (mean, 37 days). The preoperative erythrocyte sedimentation rate (ESR) was 15-85 mm/1 h (mean, 50.2 mm/1 h). The C reactive protein (CRP) was 4.4-410.0 mg/L (mean, 192.8 mg/L). The white blood cell counting was (3.4-23.8)×109/L (mean, 12.3×109/L). The absolute value of neutrophils was (1.1-22.5)×109/L (mean, 9.2×109/L). After admission, the joint fluid was extracted for bacterial culture method and mNGS test, and sensitive antibiotics were chosen according to the results of the test, and the infection was controlled in combination with surgery. Results Seven cases (70%) were detected as positive by bacterial culture method, and 7 types of pathogenic bacteria were detected; the most common pathogenic bacterium was Streptococcus lactis arrestans. Ten cases (100%) were detected as positive by mNGS test, and 11 types of pathogenic bacteria were detected; the most common pathogenic bacterium was Propionibacterium acnes. The difference in the positive rate between the two methods was significant (P=0.211). Three of the 7 patients who were positive for both the bacterial culture method and the mNGS test had the same results for the type of pathogenic bacteria, with a compliance rate of 42.86% (3/7). The testing time (from sample delivery to results) was (4.95±2.14) days for bacterial culture method and (1.60±0.52) days for mNGS test, and the difference was significant (t=4.810, P<0.001). The corresponding sensitive antibiotic treatment was chosen according to the results of bacterial culture method and mNGS test. At 3 days after the one-stage operation, the CRP was 6.8-48.2 mg/L (mean, 23.6 mg/L); the ESR was 17-53 mm/1 h (mean, 35.5 mm/1 h); the white blood cell counting was (4.5-8.1)×109/L (mean, 6.1×109/L); the absolute value of neutrophils was (2.3-5.7)×109/L (mean, 4.1×109/L). All patients were followed up 12-39 months (mean, 23.5 months). One case had recurrence of infection at 6 months after operation, and the remaining 9 cases showed no signs of infection, with an infection control rate of 90%. Conclusion Compared with bacterial culture method, mNGS test can more rapidly and accurately detect pathogenic bacteria for PJI after TKA, which is important for guiding antibiotics combined with surgical treatment of PJI.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content