west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "SUN Yuanlin" 3 results
  • Development and clinical application of a new type of intramedullary nail tail cap

    Objective To develop a new type of tail cap for closing the tail of the central hole of the interlocking intramedullary nail so as to reduce difficulty in implantation of the tail cap into intramedullary nail, and ensure the accuracy of implantation, as well as reduce unnecessary operation time. Methods In 2014, the new type of intramedullary nail tail cap (" new tail cap” for short) was successfully developed, and has been granted national utility model patent. A randomized controlled clinical trial was conducted in 34 patients with non pathological femoral shaft fractures treated between August 2014 and March 2016. The patients were randomly divided into groups A and B, 17 patients each group. There was no significant difference in gender, age, side, body mass index, cause of injury, injury to operation time, and fracture AO classification between groups (P>0.05), with comparability. All patients underwent fixation with interlocking intramedullary nail, and the new tail cap and original tail cap were used in groups A and B respectively. The blood loss and operation time during tail cap implantation, fracture healing time, and complications were recorded and compared between 2 groups; the limb function was evaluated by Klemm function evaluation standard. Results The blood loss and operation time during tail cap implantation of group A [(3.5±0.8) mL and (10.57±3.15) s] were significantly less than those of group B [(5.5±1.7) mL and (21.99±6.90) s] (t=–8.281,P=0.010;t=–10.743,P=0.009). All new tail caps were successfully implanted by one-time in group A, and the one-time success rate was 100%; the original tail cap exfoliation occurred in 3 cases of group B, and the one-time success rate was 82.4%. All the patients were followed up 6-16 months (mean, 9.7 months); there was no deep infection, loosening or breakage of internal fixation, and other serious complications. The time of fracture healing was (16.4±3.2) weeks in group A and (15.8±3.5) weeks in group B, showing no significant difference (t=0.514,P=0.611). At last follow-up, according to the Klemm function evaluation standard, the results were excellent in 14 cases and good in 3 cases in group A, and were excellent in 11 cases and good in 6 cases in group B, showing no significant difference between 2 groups (χ2=0.142,P=0.707). Conclusion The new type of femoral intramedullary nail tail cap can simplify operation, shorten operation time, and reduce blood loss, and it has satisfactory effectiveness.

    Release date:2017-04-12 11:26 Export PDF Favorites Scan
  • Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation

    ObjectiveTo report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation.MethodsA new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B (n=16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score (P>0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score.ResultsThe operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B (P<0.05), but there was no significant difference in the incision length between 2 groups (t=0.672, P=0.507). All the patients were followed up 18-30 months (mean, 24 months). In group A, there were 1 case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups (P=1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B (t=2.270, P=0.031); but there was no significant difference in the Rockwood grading scores between the 2 groups at 6 months and at last follow-up (P>0.05). At last follow-up, according to the Rockwood scoring standard, the results of group A were excellent in 13 cases, good in 2 cases, poor in 1 case, the excellent and good rate was 93.75%; the results of group B were excellent in 11 cases, good in 4 cases, poor in 1 case, and the excellent and good rate was 93.75%; there was no significant difference between 2 groups (Z=–0.748, P=0.455).ConclusionThe new type of anatomic locking plate accords with the Chinese anatomical characteristics. It has the advantages of easy operative procedure, less surgical trauma, shorter operation time, less intraoperative blood loss, shorter hospitalization time, and it can achieve better results in the treatment of sternoclavicular joint fracture and dislocation.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • Development and biomechanical study of anatomical locking plate of sternoclavicular joint

    Objective To develop an anatomical locking plate in accordance with the anatomical characteristics of the sternoclavicular joint, which is reliable fixation and easy to operate, so as to provide an ideal internal fixation device for the treatment of sternoclavicular joint dislocation or peripheral fractures. Methods Gross measurement and CT measurement were performed on the 8 adult antiseptic and moist cadaver specimens (16 sides) to measure the parameters of surrounding bone structure of the sternoclavicular joint. The parameters included the thickness of presternum, sternal notch width, anteroposterior diameter of proximal 1/3 of clavicle, upper and lower diameters of proximal 1/3 of clavicle, angle between proximal end of clavicle and presternum in coronal plane, and angle of thoracoclavicular joint at anatomic position forward. According to the anatomical parameters and biomechanical properties of the specimens, the anatomical locking plate was designed and developed. The sternoclavicular ligament and joint capsule of all the specimens were completely cut off to make the sternoclavicular joint dislocation model. The left and right sternoclavicular joint of each specimen were randomly divided into experimental group (anatomic locking plate fixation) and control group (oblique T shape locking plate fixation). The sternoclavicular joint activity and common force mechanism was simulated on the universal mechanical testing machine, and the clavicular distal load test, sternoclavicular joint torsion test, and anti-pulling of steel plate manubrium part test were performed. Results The differences between the anatomical parameters of gross measurement and CT measurement were not significant (P>0.05). In the clavicular distal load test, when the anatomical position perpendicular to the distal clavicle back loading to 20 N, the displacement of loading point in the experimental group was (8.455±0.981) mm, which was significantly less than that in control group [(10.163±1.379) mm] (t=–3.012,P=0.020); the distal clavicle displacement of loading point of experimental group and control group were (5.427±1.154) mm and (6.393±1.040) mm, respectively, showing no significant difference (t=–1.459, P=0.188). In the sternoclavicular joint torsion test, the torque of experimental group was significantly greater than that of control group when the clockwise torsion angle was at 2, 4, 6, 8, and 10 degrees and the counterclockwise torsion angle was at 4, 6, 8, and 10 degrees (P<0.05). The torsional stiffness in the experimental group under clockwise and counterclockwise condition was 0.122 and 0.108 N·m/° respectively, which were significantly higher than those in the control group (0.083 and 0.078 N·m/° respectively) (F=67.824, P=0.000; F=20.992, P=0.002). In the anti-pulling of steel plate manubrium part test, the maximum pullout force of experimental group [(225.24±16.02) N] was significantly higher than that in control group [(174.40±21.90) N] (t=5.785, P=0.001). Conclusion The new type of anatomical locking plate can realize the sternoclavicular joint three-dimensional fixation, and has the advantages of reliable fixation, simple operation, less trauma, superior biomechanical properties, and earlier functional exercise. It may be an ideal internal fixation device in clinical treatment of sternoclavicular joint dislocation or peripheral fractures.

    Release date:2018-01-09 11:23 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content