west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "TIAN Dehu" 13 results
  • TREATMENT OF OLD SCAPHOID FRACTURE WITH ABSORBABLE SCREW

    To explore a new approach to treat old scaphoid fracture by grafting bones from distal radius and fixing absorbable screws. Methods From January 2002 to May 2007, 18 patients with old scaphoid fractures were treated by grafting bones from distal radius and fixing absorbable screws. All of the 18 patients (13 males and 5 females, aged from 17 to 41 years old) had the injury history of the palm of hand touching the ground. They felt tenderness on the anatomical snuff-box and tubercle of scaphoid bone. The grasping force decreased. The range of motion of the wrist was (36 ± 2)° extension/(30 ± 3)° flexion, (8 ± 3)° radial is/(13 ± 2)° ulnaris. Results The average postoperative follow-up period was 15.7 months.A total of 18 cases achieved bone union. The range of motion of the wrist in the 16 healed cases was (68 ± 2)° extension/(65 ± 3)° flexion, (15 ± 3)° radial is/(28 ± 5)° ulnaris. There was no pain of motion and symptom of powerlessness. As to the other 2 cases, the range of motion of the wrist was (40 ± 8)° extension/(35 ± 6)° flexion, (8 ± 5)° radial is/(12 ± 5)° ulnaris; no obvious improvement was found; the patients occasionally felt painful in daily l ife; the extension force decreased. No infection and break of internal fixation were seen. Conclusion The absorbable screw as a new biomaterial for internal fixation has obvious advantages of good biocompatibil ity, promoting union of the fracture and no need of a second operation for removal.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • TREATMENT OF TRAUMATIC BONE DEFECT WITH GRAFT MATERIAL OF ALLOGENIC CANCELLUS COMBINED WITH AUTOLOGOUS RED MARROW

    Objective To study cl inical effects of the graft material of allogenic cancellus combined with autologousred marrow in the treatment of traumatic bone defect. Methods From February 2002 to April 2006, 38 patients of traumaticbone defect, 25 males and 13 females, aged 21-68 years old (38 on average), were treated with allogenic cancellus combined with autologous red marrow. Among them, there were 11 cases of bone nonunion caused by failure of internal fixation, 13 of serious comminuted fracture, 9 of bone defect caused by open fractures or bone infection, 5 of old fracture in need of graft. Of these fractures, there were 8 cases of shaft of humerus, 4 of intercondylar comminuted fracture of humerus, 8 of intercondylar comminuted fracture of femur, 5 of shaft of femur, 4 of open tibia fracture (Gustilo I, II type) and 9 of tibial plateau fracture. They included 17 cases of fresh fracture and 21 of old fracture. There were 23 cases of l imitations of bone defect, and the range was 3 cm × 3 cm × 2 cm - 7 cm × 4 cm × 3 cm; and the range of the large bone defect was less than 3 cm in 15 cases. According to AO/ASIF classification, there were 5 cases of type B2, 10 of type B3, 16 of type C2 and 7 of type C3. The time from fresh fracture to operation was 5-17 days (8 days on average), and the time from old fracture to operation was 5-13 months (7.5 months on average). The amount of the allograft implantation was 20-50 g (28 g on average). Results The wounds in all 38 cases obtained heal ing by first intention. All the patients were followed up for 8 months to 4 years (3.2 years on average). The X-ray films at reexamination showed that 36 patients had bone heal ing, with fresh fracture heal ing time of 2-6 months (4 months on average) and old fracture heal ing time of 3-10 months (7 months on average). The allogenic cancellus particles began to be fused with autogenous bone through creeping substitution 6-8 weeks after operation. One case, which had delayed infection, had bone union by removing internal fixation, placing irrigating tube and grafting after local stabil ity. During the follow-up of 25 months, no relapse was found. Another case had nonunion because of plate loosening. According to the Mankin and Komender standard evaluation, there were 36 cases with satisfaction (94.7%) and 2 with dissatisfaction (5.3%). Conclusion The composite graft material of allogenic cancellus combined with autologous red marrow is safe and effective for repairing fractures and bone defect.

    Release date:2016-09-01 09:18 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON HUMAN AMNIOTIC MEMBRANE FOR REPAIRING TENDON SHEATH DEFECT

    Objective To investigate the feasibility and effect of human amniotic membrane in prevention of tendon adhension after tendon sheat defect repair. Methods The amniotic membrane in size of 1.5 cm × 1.0 cm was harvested from human placenta which was voluntary donated from maternal after cesarean. Forty healthy male Leghorn chicken (aged 3-6 months) were selected, weighing (1.86 ± 0.04) kg. The model of flexor digitorum profundus tendon and tendon sheath defects was established at the third toe. After repair of the flexor digitorum profundus tendon, the human amniotic membrane was used to repair the tendon sheath defect in the right foot (group A), but tendon sheath defect was not repaired in the left foot (group B) . At 1, 2, 4, and 6 weeks after operation, the gross and histological observations were done; the degree of tendon adhesions was graded according to Tang’s tendon adhesion general observation grading standards; and the biomechanical properties (tendon slip length and total flexion angle) were tested. Results All animals survived after operation and incisions healed. Gross and histological observations showed that the new tendon sheath formed with time passing after operation in groups A and B; new tendon sheath was more maturer and smoother in group A than in group B. The degree of tendon adhesions in group A was significantly less than that in group B (P lt; 0.05) at 1 and 6 weeks after operation. The biomechanical test results showed there was no significant difference in the tendon slip length between 2 groups at 1 and 2 weeks after operation (P gt; 0.05), but the tendon slip length of group A was significantly longer than that of group B at 4 and 6 weeks after operation (P lt; 0.05). The total flexion angle of group A was significantly smaller than that of group B at 1, 2, 4, and 6 weeks after operation (P lt; 0.05). Conclusion It is effective in the prevention of tendon adhesion to use the amniotic membrane for repairing the tendon sheath defect, which is beneficial to recovery of the tendon sliding function.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • EFFECT OF TRIPTOLIDE ON ALLOGENIC TENDON TRANSPLANTATION IN REPAIRING TENDON DEFECT IN CHICKEN

    Objective Tri ptol ide can suppress immunological rejection reaction. To investigate the effect of tri ptol ide on allogenic tendon transplantation in repairing tendon defect in chicken. Methods The defect model of the third toes tendon was establ ished in 64 healthy-cleaning male Leghorn chickens (4-month-old, weighing 1.9-2.3 kg), which underwent allogenic tendon transplantation for repairing and were divided into 2 groups randomly (n=32). Tri ptol ide feeding[100 μg/(kg·d)] was given for 3 weeks in the experimental group and normal feeding in the control group. General condition of the chickens was observed after operation. The transplanted tendons were harvested from 4 chickens in each group for gross observation at 1, 2, 3, and 4 weeks after operation; the histological observation was performed at 1 and 3 weeks, and transmission electron microscope observation at 2 and 4 weeks. The blood and tendon were harvested from another 8 chickens in each group for flow cytometry and biomechanical tests respectively at 3 and 6 weeks. Results All chickens survived to the experiment end. Gross observation: with time extending, hyperemia and edema around transplanted tendon were rel ieved. Rarefaction adhering zone was seen in experimental group, and pyknotic adhering zone in control group. Histological observation: inflammatory reaction in experimental group was sl ighter than that in control group at 1 and 3 weeks. Transmission electron microscope observation: at 2 and 4 weeks, fibroblasts had big cell nucleus, more euchromatin, and l ittle heterochromatin in experimental group; however, there were small amount of rough endocytoplasmic reticulums with gentle expanded capsular space in control group, which contained sparse content. Flow cytometry test: at 3 and 6 weeks, peri pheral blood contained less CD4+ and CD8+ T lymphocytes in experimental group than in control group, and the ratio of CD4+ to CD8+ T lymphocyte significantly decreased in experimental group when compared with control group (P lt; 0.05). Biomechanical examination: at 3and 6 weeks, the maximum tensile strength in experimental group was bigger than that in control group, and tensile adhesion power in experimental group was smaller than that in control group. There were significant differences in the indexes between 2 groups (P lt; 0.05). Conclusion Tri ptol ide can suppress immunological rejection reaction, strengthen tendon healing strength, and reduce tendon adhesion in allogenic tendon transplantation.

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • REPAIR OF LARGE SKIN DEFECT OF FOREARM AND HAND USING BILATERAL GROIN FLAPS AND ABDOMINAL FLAPS

    Objective To investigate an operative method of repairing large skin defect of the forearm and the hand. Methods From July 2003 to September 2008, 11 patients with large skin defect of the forearm and the hand were repaired using bilateral groin flaps in complex with abdominal flaps, including 7 males and 4 females aged 17-55 years old (average33.5 years old). Among the 11 cases, 5 were caused by carding machine and 4 by traffic accident, and the interval between injury and operation was 90 minutes to 6 hours (average 3.5 hours); 2 cases suffered from severe cicatricial contracture deformity in the late stage of burn injury, and the interval between injury and operation was 7 months and 19 months, respectively. The size of skin defect ranged from 42 cm × 12 cm to 60 cm × 16 cm. The flaps harvested during operation was 45.0 cm × 10.5 cm - 62.0 cm × 18.0 cm in size. Pedicle division of the combined flaps was performed 4 weeks after operation. The donor site wound was repaired by direct suturing in 7 cases and by free skin grafting in 4 cases. Results All flaps survived. All incisions healed by first intention. The donor site wound all healed by first intention. Skin graft all survived. All patients were followed up for 2 months to 3 years. The flaps were soft in texture, full in contour, and normal in color. Sensory recovery of the flaps was evaluated according to the Criteria of UK Medical Research Council (1954), 4 cases were in grade S1, 6 in grade S2, and 1 in grade S3. Hand function was assessed by the Criteria of Chinese Hand Surgery Society, 7 cases were graded as excellent, 2 as good, 2 as poor, and the excellent and good rate was 81.8%. Conclusion Combined use of bilateral groin flaps and abdominal flap is an effective approach to repair large skin defect of the forearm and the hand due to its simple operative procedure and satisfying effect.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • INHIBITORY EFFECT OF TOPICAL APPLICATION OF 5-FLUOROURACIL ON INTIMAL HYPERPLASIA OF VEIN GRAFT

    Objective To assess the effect of topical appl ication of 5-fluorouracil (5-FU) on intimal hyperplasia in rabbit vein graft. Methods Sixty-four male New Zealand white rabbits, aged 5 months and weighing 2.8-3.0 kg, were randomly divided into group A, B, C, and D (n=16 rabbits per group). Artery defect model was establ ished by cutting about 1 cm artery from the middle part of the dissociated left common carotid artery. A section about 3 cm was cut from the right external jugular vein, and the harvested vein was inverted and end-to-end anastomosed to the artery defect with 9-0 non-traumatic suture. After anastomosis, the extima of the grafted veins in group A, B, and C was completely wrapped with cotton sheet (12 mm × 30 mm × 1 mm in size) immersed by 5-FU at a concentration of 50.0, 25.0, and 12.5 mg/mL, respectively, and eachvein was treated 5 times (1 minute at a time). In group D, the extima of the graft veins was treated with normal sal ine instead of 5-FU. The grafted veins were obtained 1, 2, 4, and 6 weeks after operation, HE staining and Masson staining were preformed for histological changes of grafted vein wall, prol iferating cell nuclear antigen (PCNA) immunohistochemistry staining and TUNEL label ing staining were conducted for prol iferation and apoptosis of smooth muscle cell of the grafted vein, and transmission electron microscope observation was performed for cellular ultrastructure. Results The HE staining, Masson staining, and PCNA immunohistochemistry staining showed that the thickness of intima in group A and B was obviously less than that in group C and D at 1, 2, 4, and 6 weeks after operation, and the prol iferation cells in group A and B were less than that in group C and D at 1, 2, and 4 weeks after operation. The thickness of the intima, the degree of intima hyperplasia, the degree of vessel lumen stenosis of four groups at different time points were as follows: at 1 week after operation, group A [(12.69 ± 1.68) μm, 0.73 ± 0.05, 0.025 ± 0.003], group B [(17.52 ± 2.01) μm, 0.86 ± 0.06, 0.027 ± 0.004], group C [(21.92 ± 1.85) μm, 1.06 ± 0.09, 0.036 ± 0.006] and group D [(26.45 ± 3.86) μm, 1.18 ± 0.08, 0.041 ± 0.005]; at 2 weeks after operation, group A [(24.61 ± 2.91) μm, 0.86 ± 0.06, 0.047 ± 0.003], group B [(37.28 ± 2.78) μm, 1.17 ± 0.09, 0.060 ± 0.004], group C [(46.52 ± 2.25) μm, 1.44 ± 0.08, 0.073 ± 0.003], and group D [(52.07 ± 3.29) μm, 1.45 ± 0.05, 0.081 ± 0.006]; at 4 weeks after operation, group A [(61.09 ± 6.84) μm, 1.38 ± 0.08, 0.106 ± 0.007], group B [(63.61 ± 8.25) μm, 1.40 ± 0.07, 0.107 ± 0.010], group C [(80.04 ± 7.65) μm, 1.64 ± 0.07, 0.129 ± 0.011], and group D [(84.45 ± 9.39) μm, 1.68 ± 0.10, 0.139 ± 0.014]; at 6 weeks after operation, group A [(65.27 ± 5.25) μm, 1.46 ± 0.07, 0.113 ± 0.005], group B [(65.82 ± 7.12) μm, 1.45 ± 0.05, 0.112 ± 0.011], group C [(84.45 ± 9.39) μm, 1.69 ± 0.09, 0.135 ± 0.007], and group D [(87.27 ± 8.96) μm, 1.76 ± 0.05, 0.140 ± 0.012]. Group A and B were inferior to group C and D in terms of the above three parameters and cell prol iferation index 1, 2 and 4 weeks after operation (P lt; 0.05). Group A and B were superior to group C and D in terms of cell apoptosis index of intima and media 1 and 2 weeks after operation (P lt; 0.05). Transmission electron microscope observation showed that the synthetic cell organelles such as rough endoplasmic reticulum, golgi apparatus, and ribosome in group A and B were obviously less than those in group C and D (P lt; 0.05). Conclusion Topicalappl ication of 5-FU can effectively inhibit intima hyperplasia of the vein grafts.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • LESS INVASIVE LEVERAGE REDUCTION WITH EXTERNAL FIXATOR SUPPORTED AND BONE GRAFT FORTREATMENT OF UNSTABLE FRACTURES OF DISTAL RADIUS

    【Abstract】 Objective To assess the results of treatment of unstable distal radius fractures with leverage reductionand bone graft assisted by external fixators. Methods From September 2005 to May 2007, 27 cases of unstable distal radius fractures were treated by leverage reduction and bone graft, meanwhile assisted by external fixators. The cases included 16 males and 11 females, aged from 18 to 69 years with an average of 49. 3 years. Fractures were caused by fall ing in 19 cases, crash from high place in 1 case, traffic accident in 6 cases, and obtuse strike directly in 1 case, which were all closed fresh bone fractures. According to the standard of AO, all cases were classified as type C1 in 13 cases, type C2 in 11 cases, and type C3 in 3 cases. The palmar incl inination was from - 38° to 10°(mean - 12.2°); the ulnar deviation angle was from 6° to 30° (mean 19. 1°) before operations. The operations were performed from 1 to 3 days after injuries. The function of the carpal joints and the boneheal ing conditions were evaluated after operations. Results All cases were followed up for 4-24 months(mean 13. 1 months). No compl ications such as pin loosening, dislocation of fixators, injury of blood vessels and radial nerves, pin track infections occurred. According to Mcbride scoring, the results were excellent in 10 cases, good in 13 cases, fair in 3 cases and poor in 1 case, the excellent and good rate being 85. 2%. One case had traumatic arthritis and 1 case had wrist joint stiffness. All achieved fractures uniton 8-10 weeks (mean 9.3 weeks) after operations. The palmar incl inination angle was from 0° to 20° (mean 13. 4°); the ulnar deviation angle was from 10° to 33° (mean 22. 1°) after operations. Conclusion Treatment of unstable fractures of the distal radius by use of leverage reduction and bone graft with external fixator offers many advantages, such as simple operation, satisfactory reduction, rigid fixation, excellent function and lower incidence rate of traumatic arthritis.

    Release date:2016-09-01 09:10 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF MICRO TRANSVERSE FLAP PEDICLED WITH SUPERFICIAL PALMAR BRANCH OF RADIAL ARTERY FROM PALMAR WRIST TO REPAIR SKIN DEFECT OF FINGER

    Objective To investigate the clinical application of micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist to repair skin defect of finger. Methods Twenty-six cases (26 fingers) with skin defect of finger were repaired with micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist between December 2011 and February 2013. There were 20 males and 6 females with the average age of 31.5 years (range, 20-56 years). The causes of injury included cutting injury in 20 cases and crushing injury in 6 cases. The time from injury to admission was 1-5 hours with an average of 2 hours. Injured fingers included thumb in 6 cases, index finger in 6 cases, middle finger in 6 cases, ring finger in 4 cases, and little finger in 4 cases; the locations were the dorsal side of the finger in 6 cases, lateral side in 6 cases, and the volar of the finger tip in 14 cases; there were 4 cases on the proximal phalangeal skin, 8 cases on the middle phalangeal skin, and 14 cases on the distal phalangeal skin. The defect area ranged from 2.0 cm × 1.5 cm to 4.0 cm × 2.0 cm, and the flap area ranged from 2.5 cm × 2.0 cm to 4.5 cm × 2.5 cm. All the donor sites were directly sutured. Results The flaps of 25 cases survived well after operation, and wound healed by first intention; 1 case had partial necrosis and the wound had a scar healing by changing dressing. All cases were followed up 6-12 months (mean, 10 months). The color and appearance of the flaps were satisfactory with tender texture. The two-point discrimination of the flap was 5-8 mm (mean, 6.8 mm). The donor sites healed primarily without scar contracture and limitation of wrist flexion or extension. Conclusion The micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist is a good option to repair skin defect of finger. It has the advantages of hidden donor site, the same operative field, great comparability of flap and finger skin, and it can be used as a vascularized tendon or nerve graft.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
  • DIAGNOSE AND TREATMENT OF INTRA-ARTICULAR FRACTURE OF FIFTH METACARPALE BASE WITH CARPOMETACARPAL JOINT DISLOCATION

    Objective To investigate the diagnose and treatment of intra-articular fracture of the 5th metacarpale base with carpometacarpal joint dislocation (reverse Bennett fracture). Methods Between January 2008 and March 2012, 26 cases of reverse Bennett fracture were treated. There were 20 males and 6 females, aged 19-48 years (mean, 26 years). The injury causes included boxing injury in 19 cases, falling injury in 3 cases, heavy pound injury in 3 cases, and crushing injury in 1 case. According to Lundeen classification, there were 8 cases of type A, 9 cases of type B, 3 cases of type C, and 6 cases of type D. The time from injury to operation ranged 1-8 days with an average of 4 days. All patients underwent open reduction and internal fixation with Kirschner wires, screws, or plates by L-shaped dorsal incision. Results Primary healing was obtained in all incisions; no infection, hematoma, and necrosis occurred after operation. All patients were followed up with an average time of 12.5 months (range, 8-24 months). X-ray films showed that all fractures healed after 6-8 weeks (mean, 6.5 weeks); no delayed union or nonunion and no the 5th carpometacarpal joint dislocation were observed. Two cases had mild osteoarthritis. According to the upper extremity functional evaluation standard by Hand Surgery Branch of Chinese Medical Association, the results were excellent in 22 cases, good in 3 cases, and fair in 1 case, with an excellent and good rate of 96.2%. Conclusion For patients with reverse Bennett fracture, good results can be obtained if early diagnose is done and appropriate internal fixation is selected.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • EFFECTS OF 5-FLUOROURACIL ON TENDON ADHESION FORMATION AFTER FLEXOR TENDON REPAIR

    To evaluate the effect of 5-fluorouracil (5-FU) appl ied topically on preventing adhesion andpromoting functional recovery after tendon repair. Methods From August 2003 to June 2007, 48 patients with flexor tendonrupture of the fingers by sharp instrument were treated and randomly divided into two groups. In 5-FU group, 39 fingers of 26 patients included 17 males and 9 females, aged (29.3 ± 9.8) years; the locations were zone I in 19 fingers and zone II in 20 fingers; single finger was involved in 12 cases and more than 2 fingers were involved in 14 cases; and the time from injury to operation was (2.4 ± 1.6) hours. In control group, 36 fingers of 22 patients included 14 males and 8 females; aged (26.1 ± 8.7) years; the locations were zone I in 16 fingers and zone II in 20 fingers; single finger was involved in 10 cases and more than 2 fingers were involved in 12 cases; and the time from injury to operation was (2.1 ± 1.8) hours. No statistically significant difference was found in constituent ratio of age, gender, injured fingers and their zones, between two groups (P gt; 0.05). The repair site in 5-FU group was given 5-FU at a concentration of 25 mg/mL with a soaked sponge, and the synovial sheath of the repaired site was wrapped with the 5-FU-soaked sponge for 1 minute for 4 times after the tendons were repaired; normal sal ine was used in the control group. Results Wound healed by first intention and no infection and tendon rupture occurred in two groups. The patients were followed up for 3-8 months (mean 4.1 months) and 3-8 months (mean 3.9 months) in 5-FU group and in control group respectively. The functional recovery degrees of the fingers were evaluated with total active movement (TAM) evaluation system. In 5-FU group, the results were excellent in 22 fingers, good in 13 fingers, fair in 3 fingers and poor in 1 finger; the excellentand good rate was 89.7%. In control group, the results were excellent in 11 fingers, good in 15 fingers, fair in 9 fingers andpoor in 1 finger; the excellent and good rate was 72.2%. There was statistically significant difference in the functional recovery degrees of fingers between two groups (P lt; 0.05). The 2 fingers which had a poor result in 5-FU group and control group were served with tenolysis was performed in 2 cases having poor results after 6 months of operation and had an excellent result at last. Conclusion 5-FU appl ied topically can reduce tendon adhesions after the ruptured tendon repair.

    Release date:2016-09-01 09:14 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content