  • Three-point Bending Test of Two Methods for Rib Internal Fixation

    ObjectiveTo use claw-shaped blade plate and self-made 'titanium clip' blade plate for rib fracture fixation, and compare outcomes of these two internal fixation methods through mechanical tests. MethodsThoracic cage specimens of six adults (male)corpses were numbered. Bilateral 4th, 6th and 8th thoracic ribs of each corpse were taken from the rib nodules (0%)to costal cartilage junction (CJJ points, 100%)along the long axis of the ribs. Rib fragments about 130 mm in length with 50% locus were selected for mechanical tests of the lateral area. A total of 36 rib fragments were sampled and numbered. Each rib fragment was placed on electronic universal mechanical tester. A span of 100 mm and a loading speed of 2.5 mm/min were set to perform a three-point bending test until specimens fractured. The loads at displacement of 2, 4, 6, 8, 10, 15 and 20 mm respectively and maximum load were recorded, then the load-displacement curve was drawn. Above rib fragments were randomly divided into 2 groups, which were fixed using 'titanium clip' blade plate (titanium plate group)and claw-shaped blade plate (claw-shape group)respectively. Three-point bending test was performed under above loading conditions until the fixed specimens fractured again, and relevant data were recorded. ResultsBefore fixation, there was no statistical difference in maximum load and peak deformation of the 4th, 6th and 8th ribs between the 2 groups (P > 0.05). Maximum load and peak deformation of the 4th, 6th and 8th ribs in the claw-shape group after fixation were statistically different from those before fixation (P < 0.05). Maximum load and peak deformation of the 4th, 6th and 8th ribs in the titanium plate group after fixation were also statistically different from those before fixation (P < 0.05). After fixation, maximum loads of the 4th, 6th and 8th ribs in the claw-shape group were statistically different from those in the titanium plate group (P < 0.05), but there was no statistical difference in peak deformation between the 2 groups (P > 0.05). ConclusionsFractured ribs fixed with 'titanium clip' blade plates are more stable and stronger than those fixed with claw-shaped blade plates.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content