west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Variation" 4 results
  • Anatomical Character and Intraoperative Prevention of Non-Recurrent Laryngeal Nerve

    Objective To investigate the anatomical character and variation of non-recurrent laryngeal nerve (NRLN), and to explore measurement to identify and prevent injury of this nerve during thyroidectomy. Methods Clinical data of 2 211 patients who underwent thyroidectomy from Jan. 2007 to Jun. 2012 in Peking Union Medical College Hospital were analyzed retrospectively, and 114 patients with NRLN of related literature reviews were analyzed too. Results There were 3 479 recurrent laryngeal nerve (2 211 cases) which were exposed during thyroid operation in Peking Union Medical College Hospital, of which 11 cases were confirmed to be right NRLN (0.32%, 11/3 479). Of the 11 cases, 3 cases were typeⅠ, 7 cases were typeⅡA, and 1 case was typeⅡB, one case was also found to have a recurrent branch. None of them injured during operation. One hundred and fourteen cases of NRLN (0.14%-4%) were found in literature reviews. Of the 114 cases, 109 cases were confirmed to be right NRLN, of which 4 cases were typeⅠ (3.7%, 4/109), 75 cases were typeⅡA (68.8%, 75/109), 9 cases were typeⅡB (8.3%, 9/109), 21 cases were unclear (19.3%, 21/109), 3 cases were also found to have a recurrent branch (2.8%,3/109). Five cases were confirmed to be left NRLN, of which 2 cases were typeⅡA, 3 cases were unclear, 1 case was also found to have a recurrent branch. Of all the 104 cases reported by treatises and case reports, 16 cases injured during operation, of which 1 case was typeⅠ, 9 cases were typeⅡA, 6 cases were unclear. Conclusions NRLN, which is a rare anomaly, usually happens on the right, and very vulnerable during thyroid surgery. The most usually injured type is typeⅡA. Fully acknowledgment of the NRLN and its variant types is very helpful to avoid damage during thyroid surgery.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF MULTIPLE ARTERIES IN RENAL TRANSPLANTATION FROM LIVING RELATED DONORS

    To discuss renovascular reconstruction during l iving related donor kidney transplantation (LDKT). Methods Seventy-seven cases of LDKT from April 2006 to March 2008 were retrospectively analyzed, including 63 cases in single renal artery group and 14 cases in multi ple artery group. In multi ple artery group, there were 3 cases of three arteries and 11 cases of double arteries; 9 cases of donated left kidneys and 5 cases of donated right kidneys. Potential donors underwent fully medical evaluation before operation, including donor-reci pient human leucocyte antigen matchingand a cross match test. The donor’s operation of the incision either underneath the 12th rib approaching the dorsal lumbar was performed and the transplantation operation adopted the extraperitoneal approach in the contralateral fossa il iac. The arteries in the multiple artery group were implanted onto the external (or common) il iac artery different from the orthodox method. Results In multiple artery group, no blood transfusion during operation was performed, no compl ication occurred after operation and all donors were discharged after 7-9 days of postoperation. After a follow-up of 3 months to 1 year, all the recipients kept normal kidney function without renal tubule necrosis, renal artery embol ism, vascular stenosis, urinary fistula and ureter necrosis. The ultrasound examination showed that the transplanted kidney had good blood supply. There was no significant difference in the time of urine secretion, serum creatinine level after 1 week of operation, length of hospital ization between the multiple artery group and the single artery group (P gt; 0.05). Conclusion The accurate treatment of multiple artery anastomosis are critical for the safety of the LDKT.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • Application of thin CT angiography of pedicle sagittal plane of axis for preoperative evaluation of pedicle screw placement procedure

    ObjectiveTo explore the application value of thin CT angiography (CTA) of pedicle sagittal plane of axis for preoperative evaluation planning pedicle screw placement.MethodsBetween February 2016 and August 2017, 34 patients (68 pedicles) who underwent thin CTA scan before posterior axial surgery were retrospectively analyzed. The vertebral artery development was statistically analyzed. The continuous layers of transverse process hole pedicle height more than or equal to 4 mm (f) were measured and read. The axial fixation methods, clinical manifestations of vertebral artery and spinal cord injury and the bone union of fractures or implants were recorded. Postoperative results of pedicle screws were evaluated by CT scan.ResultsThe right sides of 8 cases and the left sides of 18 cases were dominant vertebral arteries, and equilibrium was reached in 8 cases; f>9 layers were found in 16 pedicles,f=9 layers in 27 pedicles, f=8 layers in 17 pedicles, and f<8 layers in 8 pedicles. The 43 pedicles off≥9 layers used pedicle screw fixation; in the 17 pedicles of f=8 layers, 16 used pedicle screw fixation, and the other one used laminar screw fixation; in the 8 pedicles of f<8 layers, 4 used pedicle screw fixation, and the other 4 used laminar screw fixation. A self-defined pedicle screw grading system was used to evaluate the excellence, and the result showed that,f>9 layers: 14 pedicles were class A, 2 were class B, none was class C;f=9 layers: 16 pedicles were class A, 7 were class B, 4 were class C; f=8 layers: 3 pedicles were class A, 5 were class B, 8 were class C; f<8 layers: none was pedicles class A or class B, 4 were class C. The other 4 lamina screws fixation didn’'t invade the spinal canal. One case of pedicle class C showed clinical manifestations of mild dizziness and drowsiness. The patients were followed up for 6-11 months with an average of (8±3) months, and the fracture or bone graft fusion were observed after 6 months of following-up.ConclusionBased on preoperative CTA thin layer scanning, through measuring and reading continuous layers of transverse process hole pedicle height more than or equal to 4 mm, can effectively judge the security of axial pedicle screws in order to subsequently choose the reasonable operation methods so as to improve success rate and decrease surgical risk.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
  • Variation of right B2 downwards-shift: A special type of tracheal bronchus

    Background To analyze and summarize the changes of the bronchus and vessels of right B2 downwards-shift. Methods Patients who underwent three-dimensional computed tomography bronchography and angiography (3D-CTBA)Between January 2019 and January 2022 were screened. Based on the opening position of B1+3, we classified bronchial variations into normal type, over type, and tracheal-bronchus type. Results Initially 5 280 patients were screened, and finally 6 patients were included, including 1 male and 5 females, aged 29 to 71 years. According to our bronchial classification, there were 4 (66.7%) patients of the normal type in this group, 1 (16.7%) patient was the over type;1 patient (16.7%) was the tracheal-bronchus type.In artery, 4 (66.7%) patients was the Tr.sup+A.post type and 2 (33.3%) patients was the Tr.sup+Tr.inf+A.post type have. In vein, 2 (33.3%) patients was the Ⅰab+UVPBI type, 1 (16.7%) patient the Ⅰb+UVPBI type, 1 (16.7%) patient the Anterior+UVPBI type have, 1 (16.7%) patient the Central+UVPBI type and 1 (16.7%) patient the Central type. Conclusion There is a variation combination in the right B2 downwards-shift: the right B2 downwards-shift, exist posterior artery(A.post), the posterior oblique fissure is poorly developed(RS2 and RS6 are interconnected).Therefore, it is easier for us to dissect and disconnect B2 intraoperative, but it is necessary to be vigilant for vascular damage caused by opening the posterior oblique fissure.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content