ObjectiveTo compare and analyze the postoperative quality of life in patients after minimally invasive coronary artery bypass grafting (MICABG) and conventional median thoracotomy off-pump coronary artery bypass grafting surgery (OPCABG). MethodsFrom November 2015 to January 2018, 94 patients who underwent MICABG in the Peking University Third Hospital were included in the MICABG group. During the same period 441 patients who received OPCABG were included in the OPCABG group. The patients were matched by using propensity score matching method with a ratio of 1∶1. The quality of life was compared between two groups at 1 month, 6 months and 12 months after the surgery using SF-36 scale. ResultsA total of 82 patients were matched for each group. In the MICABG group, there were 66 males and 16 females with a mean age of 62.6±8.2 years. In the OPCABG group, there were 67 males and 15 females with a mean age of 63.2±13.2 years. One month after the operation, the physical health assessment (PCS) and mental health assessment (MCS) of the MICABG group were higher than those of the OPCABG group (50.3±10.6 points vs. 46.1±10.3 points, P=0.011; 59.5±9.3 points vs. 54.2±11.0 points, P=0.002). Scores of these following five dimensions: general health, physical functioning (PF), role-physical, social functioning (SF), role-emotion in the MICABG group were higher than those in the OPCABG group, while the score of body pain was inferior to that in the OPCABG group, and the differences were statistically significant (P<0.05). Six months after the surgery, the PCS and MCS of the two groups were not statistically different (80.0±13.1 points vs. 77.8±12.4 points, P=0.271; 81.6±13.5 points vs. 80.4±11.2 points, P=0.537). However, the scores of PF and SF in the MICABG group were still higher than those in the OPCABG group (P<0.05). Twelve months after the surgery, there was no statistical difference in the score of each dimension between the two groups (P>0.05). ConclusionThe improvement of quality of life within 6 months after MICABG is better than that of OPCABG, and it is similar between the two groups at 12 months after the surgery, indicating that MICABG has a certain effect of improving the short-term quality of life after the surgery, and the long-term quality of life is comparable to conventional surgery.
Objective To explore the effectiveness of the combined anteversion angle technique in total hip arthroplasty (THA) for treating ankylosing spondylitis (AS) affecting the hip joint. Methods A retrospective analysis was conducted on the clinical data of 73 patients with AS affecting the hip joint who underwent THA between August 2018 and August 2021. According to whether the combined anteversion angle technique was used in THA, the patients were divided into study group (37 cases, combined anteversion angle technique was used in THA) and control group (36 cases, traditional THA). There was no significant difference in baseline data such as gender, age, body mass index, disease duration, preoperative Harris score, range of motion (ROM), acetabular anteversion angle, acetabular abduction angle, femoral anteversion angle, and combined anteversion angle between the two groups (P>0.05). The operation time, hospital stay, and complications of the two groups were recorded and compared. The Harris score and hip ROM were compared between the two groups before operation, at 1, 3, 6, 12 months after operation, and at last follow-up. The acetabular component anteversion angle, femoral component anteversion angle, acetabular component abduction angle, and component combined anteversion angle were measured postoperatively. ResultsThe operation time in the study group was significantly shorter than that in the control group (P<0.05), and there was no significant difference in hospital stay between the two groups (P>0.05). There was no intraoperative complication such as acetabular and proximal femoral fractures, neurovascular injuries in both groups, and the incisions healed by first intention. All patients were followed up 2-3 years, with an average of 2.4 years; there was no significant difference in the follow-up time between the two groups (P>0.05). During the follow-up period, there was no complication such as hip dislocation, wound infection, delayed wound healing, deep venous thrombosis, and hip dislocation in both groups. The hip Harris score and ROM of the two groups gradually increased with time after operation, and the differences were significant when compared with those before operation (P<0.05); the above two indicators of the study group were significantly better than those of the control group at each time point after operation (P<0.05). Extensive bone ingrowth on the surface of the components could be observed in the anteroposterior X-ray films of the hip joint of the two groups at 12 months after operation, and the acetabular components was stable without femoral stem subsidence, osteolysis around the components, and heterotopic ossification. At last follow-up, the acetabular component anteversion angle, femoral component anteversion angle, and component combined anteversion angle in the study group were significantly superior to those in the control group (P<0.05), except that there was no significant difference in the acetabular component abduction angle between the two groups (P>0.05). Conclusion For patients with AS affecting the hip joint, the use of the combined anteversion angle technique during THA effectively promotes the recovery of hip joint function and enhances the postoperative quality of life of patients when compared to traditional THA.
Objective To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores (P<0.05). Conclusion Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.