  • BIOCOMPATIBILITY OF MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDER

    Objective To investigate the biocompatibil ity of sil ica gel embedded permanent magnets of themicturition alert device dedicated to neurogenic bladder. Methods According to the national standards of biologicalevaluation of medical equipment (GB/T 16886), Shanghai Biomaterial Research and Test Center was confided to evaluate the biocompatibil ity of sil ica gel embedded permanent magnets both in vitro and in vivo, including cytotoxicity test, sensitization test, primary skin irritant test and acute general toxicity test. The cytotoxicity test was performed according to the agar diffusion method. The L929 cell discoloration index and cell lysis index were counted at 24 hours after the action of the specimen. The sensitization test was performed according to the maximal dose method. The skin response was evaluated in 30 male albino guinea-pigs at 24 and 48 hours after the routine induction and provocation of leaching l iquors of the specimen. The primary skin irritant test was evaluated in 2 male healthy New Zealand rabbits according to the local tissue response at 24, 48 and 72 hours after intradermal injection of leaching l iquors of the specimen. The acute general toxicity test was evaluated in 10 male Kumming mice musculus albus according to animal condition at 4, 24, 48 and 72 hours after injection of leaching l iquors of the specimen through the caudal vein. Both the general reaction of canines and the pathology of the local bladder walls were observed at 2, 4 and 8 weeks after a permanent magnet was fixed on the anterior wall of urinary bladder in three canines. Results No sensitization, no stimulation and no acute general toxicity were observed except sl ight cytotoxicity to sil ica gel embeddedpermanent magnets. After implantation of a permanent magnet, the canines showed excellent tolerace, which manifested as no abnormal ity in spirit, appetite, urine and stool, healed wounds and no infection. Adhesions occurred between the epiploon and the bladder wall around the permanent magnet in two canines at 2 and 4 weeks, and between the lower abdominal wall and the bladder wall around the permanent magnet in the other canine at 8 weeks. The local bladder wall below permanent magnet was thickened, the fibrous capsule around the permanent magnet was thin, but the bladder mucosa was normal. Inflammatory reaction such as congestion, edema and inflammatory cells lessened from the serosa layer to the mucosa layer microscopically. Conclusion Sil ica gel embedded permanent magnets used in the micturition alert device dedicated to neurogenic bladde has excellent biocompatibil ity and meet the criteria for cl inical appl ication.

    Release date:2016-09-01 09:17 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON RECONSTRUCTION OF PHYSIOLOGICAL REFLEX ARC AFTER MEDULLARYCONE INJURY IN RATS

    To establ ish the animal model of the artificial physiological reflex arc with the reconstruction of the sensory and the motorial functions of atonic bladder simultaneously in the rats, and to provide the foundation to furtherinvestigate the repairing effectiveness of this technique. Methods There were 20 adult male SD rats (weighing 280-300 g)which were randomly divided into 2 groups (n=10): group A and group B. Group A was anastomosis of the ventral roots(VR) and the dorsal roots (DR) between L6 and S2 simultaneously to establ ish the model of the artificial physiological reflex arc. Group B was anastomosis of the main trunk between L6 and S2 to establ ish the model. The contents of the observation included: ① To measure the external diameter of the VR, DR and the main trunk of L6 and S2 with the sl iding cal iper; and to measure not only the distance between L6 and S2 but also the separable length of L6 with the ruler. ② Fast Blue dyeing of the VR, DR and the main trunk of L6 and S2 was performed to count their nerve fibers assisted by the Leica FW4000 system 2 weeks after opertation. ③ The observation of the urination of the rat and BBB scoring to evaluate the motorial function of the lower l imbs was performed postoperatively. Results ① L6 located in the lateral side of the S1-4 in the vertebral body of L6. The external diameters of the VR, DR and the main trunk of L6 were (0.68 ± 0.13), (0.88 ± 0.10) and (1.54 ± 0.33) mm, respectively, while those of S2 were (0.62 ± 0.08), (0.79 ± 0.14) and (1.39 ± 0.42) mm, respectively. The distance between L6 and S2 was (14.21 ± 1.95) mm, and the separable length of L6 was (10.76 ± 2.11) mm. Furthermore, the microdissection indicated the VR and the DR between L6 and S2 could be anastomosed respectively with no-tension at the level of the vertebral body of L6; and the main trunk of L6 and S2 could be anastomosed with no-tension at the level of the confluens of L5, 6. ② With Fast Blue dyeing, there were 892 ± 32, 354 ± 26 and 532 ± 17 nerve fibers of the VR, DR and the main trunk of L6, respectively. And there were 788 ± 29, 325 ± 19, and 478 ± 22 nerve fibers of the VR, DR and the main trunk of S2, respectively. There were no volar ulcer,trichomadesis and self-eating of the affected l imbs in the both groups postoperatively. The urinations of the rats after operationwere not different from those before operation. The mean BBB scores of pre- and postoperation in group A were 20.20 ± 0.35 and 19.80 ± 0.23, respectively; the mean BBB scores of pre- and postoperation in group B were 20.20 ± 0.35 and 19.20 ± 0.31, respectively. There was no significant difference of the above indexes between group A and group B (P gt; 0.05). Conclusion Anastomosis of the VR and the DR between L6 and S2 simultaneously in rats is an ideal animal model to establ ish the artificial physiological reflex arc owing to its simple and reproducible procedures.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDERS

    To introduce a micturition alert device dedicated to neurogenic bladders. Methods The design and mechanism of the micturition alert device were explained, the effectiveness was tested in a cranine experiment. Results The micturition alert device consisted of a permanent magnet sutured on the anterior bladder wall and a warning unit sutured on theinferior abdominal wall. The warning unit was assembled with a compass-l ike switch, a power supply, a buzzer and a power switch. Bladder volume determined the position of the magnet which determined the magnetic field at the point of the warning unit. The change of magnetic field was read by the warning unit. With increasing bladder volume from initial state to 200 mL in 8 dogs, the magnet moved cranially 32.8 mm averagely (from 31.3 mm to 34.1 mm) and the hand of warning unit turned 52° (from 47° to 57°). The value of the warning unit was correlated positively to the bladder volume (r =1.0, P lt; 0.01). If the desired bladder volume was determined as 150 mL to activate the warning unit to alarm in advance, the fullness of bladder was 147.6 mL averagely from135 mL to 160 mL, with an error less than 15 mL (10%). Conclusion The micturition alert device including a warning unit and permanent magnet could monitor bladder volume continuously and alarm in time for the patients with loss of micturition desire. It is simple, easily-made, cheap and conveniently used. It is worth of further study.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • MAJOR INFLUENTIAL FACTORS OF THE MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDERS

    Objective To study major influential factors of the micturition alert device dedicated to neurogenic bladders for the product design and cl inical appl ication of the device. Methods One ferrite permanent magnet with thickness and diameter of 3 mm and 10 mm, respectively, and three NdFeB permanent magnets with the thickness of 3 mm and diameter of 10, 15 and 20 mm, respectively, were used. The effects of thickness of the abdominal wall as well as the position and type of permanent magnets on the micturition alert device dedicated to neurogenic bladders were measured in vitro simulated test, when the abdominal wall was set to 2, 3, 4, 5, 6, 7, 8 and 9 cm, respectively, and the position of permanent magnets was 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12 cm, respectively. The effect of the geomagnetic field on the device was measured under the condition that the thickness of the simulated abdominal wall was set to 2, 3, 4 and 5 cm, respectively,and the position of permanent magnets was 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, respectively. Results The value showed inthe warning unit was positively correlated with the position of the ferrite permanent magnet only when the thickness ofthe simulated abdominal wall was 2 cm (r=0.632, P lt; 0.05). The correlation between the value of the warning unit andthe position of NdFeB permanent magnets was significant (r gt; 0.622, P lt; 0.05), which was intensified with the increasingdiameter of NdFeB permanent magnets, but weakened with the increasing thickness of the simulated abdominal wall. The effect of the geomagnetic field was correlated with the exposition of the body, the position of the permanent magnet and the thickness of the abdominal wall. Conclusion The major influential factors of the micturition alert device dedicated to neurogenic bladder include the magnetism and location of the permanent magnet, the thickness of the abdominal wall and the geomagnetic field. These factors are correlated with and affect each other. Reasonable allocation of these factors may optimize the device.

    Release date:2016-09-01 09:16 Export PDF Favorites Scan