find Author "WANG Tiehao" 9 results
  • Current research status of patient-reported outcomes in the field of venous thromboembolism

    ObjectiveTo summarize the applied research status on the evaluation tools of patient-reported outcome at home and abroad in patients with venous thromboembolism (VTE). MethodBy searching and analyzing the literatures, this paper summarized the concept, evaluation tools and application status of patient-reported outcome in the field of VTE. ResultsThe patient-reported outcomes can more comprehensively and accurately evaluate the disease burden and treatment effect of patients with venous thromboembolism, and can help doctors better understand patients' needs and guide individualized treatment and rehabilitation plans. ConclusionsPatient-reported outcome has a broad application prospect in the field of venous thromboembolism. Further promotion and application of patient-reported outcome can promote the development of medical research and provide reference guidelines for improving the management of patients with venous thromboembolism.

    Release date: Export PDF Favorites Scan
  • The interpretation of 2017 ESC guidelines for the diagnosis and treatment of peripheral arterial disease (lower extremity arterial disease)

    This paper interprets 2017 European Society of Cardiology (ESC) peripheral arterial disease diagnosis and treatment guidelines on lower extremity arterial disease, and in order to provide reference for clinical practice.

    Release date:2018-01-20 10:08 Export PDF Favorites Scan
  • Intraoperative ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms with internal iliac artery aneurysm

    Objective To discuss feasibility and effectivity of intraoperative ultrasound (US) during endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm. Methods A radiographic contrast nephropathy patient of abdominal aortic aneurysm and left internal iliac artery aneurysm was treated by EVAR without iodine contrast media assisted by US. Then summarized the data of this patient. Results The precise placement of the stent-graft was performed for abdominal aortic aneurysm. The left internal iliac artery aneurysm was successfully treatment with the stent-graft and coils. Intraoperative Ⅱ type endoleak from inferior mesenteric artery and Ⅰ b type endoleak from right iliac stent were identified by using US. The operative duration was 120 min and the blood loss was only 20 mL. Ⅱ type endoleak was still detected and the Ⅰ b type of endoleak was loss on postoperative a week. Conclusion Intraoperative US-assisted EVAR in patients with infrarenal abdominal aortic aneurysm represents a new option for intraoperative visualization of aortoiliac segments required as proximal or distal fixation zones and identification of endoleaks, especially in those patients with contraindications for usage of iodine-containing contrast agents.

    Release date:2018-06-15 10:49 Export PDF Favorites Scan
  • Analysis of covered endovascular reconstruction of aortic bifurcation technique for aortoiliac disease

    ObjectiveTo analyze the main points and advantages of covered endovascular reconstruction of aortic bifurcation (CERAB) technique in the treatment of complex aortic and iliac artery lesions. MethodThe data of the patient with bilateral common iliac artery stenosis and lower abdominal aortic calcification treated by CERAB technology in the Department of Vascular Surgery of West China Hospital of Sichuan University and the technology in combination with the characteristics of balloon-expandable covered stent were analyzed. ResultsThe lesions were successfully treated by CERAB technique. The stents of bilateral iliac arteries were in perfect shape and good adherence. The radiography of the abdominal aorta and bilateral internal and external iliac arteries were well displayed. ConclusionsFrom analysis results of this case, CERAB technology is effective and feasible in treatment of lesions at the bifurcation of the main aortic and iliac artery. The shape of aortic bifurcation is satisfactorily recovered. The key point for the successful implementation of this technology is balloon-expandable covered stent.

    Release date: Export PDF Favorites Scan
  • Intraoperative sac embolizaion with coils and fibrin glue during endovascular aneurysm repair for preventing postoperative type Ⅱ endoleak

    Objective To investigate the technical feasibility and effectiveness of intraoperative sac embolizaion with coils and fibrin glue for preventing type Ⅱ endoleak after endovascular aneurysm repair (EVAR). Methods A patient with abdominal aortic aneurysm (AAA), which had high risk of type Ⅱ endoleaks, was treated with combined packing of coils and fibrin glue in order to prevent type Ⅱ endoleak after EVAR. Percutaneous catheter preset and balloon occlusion were used to ensure accurate packing. Results At the end of the operation, the angiography showed that the blood flow of the stent and distal artery was unobstructed, there was no type Ⅰ and Ⅲ endoleaks, and delayed angiogram showed no collateral circulation of aneurysm. The procedure was successful. The operative duration was 120 min and the blood loss was only 20 mL. No complications such as colonic ischemia and ectopic embolism occurred, and the patient was discharged on 3 days after operation. At 6 months after follow-up, the computerized topographic angiography showed that the aneurysm cavity was completely thrombotic, without type II endoleak, and the diameter and volume of aneurysm were reduced. Conclusions The technique of intraoperative sac embolizaion with coils and fibrin glue during EVAR is safe and effective to prevent postoperative endoleaks, which is simple and feasibility. Intraoperative indwelling catheter and balloon blocking are the key points of successful implementation of this technique.

    Release date: Export PDF Favorites Scan
  • Long-term stable result of using the prosthetic graft as distal landing zone for hybrid procedure of a complicated thoracoabdominal aortic aneurysm dissection with Marfan syndrome

    ObjectiveReporting a case of hybrid procedure of extensive thoracoabdominal aortic aneurysm (TAAA) with type B dissection due to Marfan syndrome (MFS) using a prosthetic graft as the distal landing zone for stent-graft.MethodsRetrospectively summarize in-hospital profiles of a patient for who was diagnosed as MFS complicated with TAAA and type B dissection and admmited to Vascular Surgery Department of West China Hospital in May 2018. A GORE-TEX 18 mm×9 mm Y-shaped graft was sewn side-to-end to the bifurcation of left common iliac artery as the inflow site, and a self-made penta-limb graft was sewn side-to-end to the bifurcation of the 18 mm graft. The visceral and bilateral iliac arteries were reconstructed subsequently. Then, the release of the stent-graft was designed from distal to proximal. The distal part of the stent-graft was anchored into the main body of the 18 mm Y-shaped graft.ResultsThe patient underwent the operation successfully with a duaration of 6 h, blood loss of about 800 mL. No serious postoperative complications occurred. Computed tomography angiography at 2-year follow-up showed that the bypass grafts were patent without endoleak, stent migration, stent infolding or infections of the vessel graft and endograft.ConclusionThis modified management of the landing zone could be a proper choice for this kind of rare case as extensive aneurysm or dissection involved in patients with MFS.

    Release date:2021-06-24 04:18 Export PDF Favorites Scan
  • Clinical application of ultrasound-guided thrombin injection in treatment of iatrogenic femoral artery pseudoaneurysm

    ObjectiveTo explore the ultrasonic morphological indexes influencing the effectiveness of ultrasound-guided thrombin injection (UGTI) in the treatment of iatrogenic femoral artey pseudoaneury (IFAP).MethodsThe patients with IFAP treated by UGTI in the West China Hospital of Sichuan University from 2015 to 2017 were collected according to the inclusion criteria. The demographic data, comorbidities, clinical symptoms, ultrasonic morphological parameters, thrombin dosage, and postoperative complications were analyzed. The risk factors of technical success of UGTI were analyzed by logistic regression analysis. The technical success was defined as absence of flow within the FAP immediately after UGTI. ResultsA total of 53 patients who met the criteria of inclusion were included in this study. The technical and treatment success rates of UGTI were 84.9% (45/53) and 96.2% (51/53), respectively. No deep venous thrombosis, arterial thromboembolism, infection, bleeding, allergy, and other complications or death occurred in all patients. There were no statistical differences in the age, clinical symptoms, comorbidities (except hypertension, P=0.040), ultrasonic morphological parameters (except femoral artery diameter, P<0.001), and thrombin dosage between the patients with technical success and failure (P>0.05). Multivariate logistic regression analysis showed that the smaller femoral artery diameter was the risk factor of the technical failure [OR=0.350, 95%CI (0.165, 0.743), P=0.006]. Further adjustment of thebaseline data of patients (excluding patients with hypertension), the logistic regression analysis still found that smaller femoral artery diameter was the risk factor of the technical failure [OR=0.419, 95%CI (0.205, 0.860), P=0.018].ConclusionsUGTI in treatment of IFAP is minimally invasive and has a higher technical success rate. Smaller femoral artery diameter might affect technical success rate of UGTI.

    Release date: Export PDF Favorites Scan
  • The research progress on the relationship between thyroid cancer and venous thromboembolism

    ObjectiveTo summarize the current research progress on the relationship between thyroid cancer and venous thromboembolism.MethodsRetrieved the literatures about risk factors associated with thyroid cancer and venous thromboembolism both at home and abroad in recent years and reviewed the literatures.ResultsThe incidence of venous thromboembolism in patients with thyroid cancer was not high, and there were few factors related to risk factors, it might be related to the age of patient and the time of diagnosis of thyroid cancer. In addition, various types of therapeutic drugs for thyroid cancer might lead to the occurrence of venous thromboembolism.ConclusionsThe study of thyroid cancer and venous thromboembolism related factors and prethrombotic state occurrence are necessary to reduce the incidence of venous thromboembolism in thyroid cancer and improve prognosis.

    Release date:2018-12-13 02:01 Export PDF Favorites Scan
  • Single-center experience with hybrid surgery for thoracoabdominal aortic aneurysm in West China Hospital

    ObjectiveTo explore the efficacy and safety of hybrid surgery in the treatment of thoracoabdominal aortic aneurysm (TAAA). MethodsTwenty patients who were diagnosed with TAAA (including chronic thoracoabdominal aortic dissection aneurysm) and underwent hybrid surgery in Vascular Surgery, West China Hospital, Sichuan University were enrolled between January 2015 and December 2022. All the patients underwent retrograde reconstruction for visceral arteries in the open surgery. Additionally, one-stage or two-stage endovascular aortic repair with covered stents was performed. The patients’ clinical baseline information was collected. Moreover, the patients received clinical follow-up and imaging examinations postoperatively, whose informationwas collected. ResultsOne patient developed paraplegia and acute renal failure 16 days postoperatively in the hospital, and subsequently died in the hospital due to septic shock. Another patient underwent exploratory laparotomy for hemostasis due to anastomotic bleeding in the hospital. The other patients did not experience serious complications perioperatively. Nineteen patients were discharged from the hospital with long-term follow-up ranging from 10 to 144 months (median time: 48 months), and all of them had a long-term survival. No patients were observed with paraplegia, myocardial infarction, stroke, or rupture of aneurysm. None of the patients received reintervention during the follow-up, except for one patient who underwent ultrasound-guided puncture and suctionin the aneurysmallumen. ConclusionHybrid surgery is an effective treatment for TAAA with favorable short- and long-term safety and efficacy.

    Release date: Export PDF Favorites Scan