west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WANG Yiwei" 2 results
  • Nocturnal oximetry saturation monitoring combined with clinical score in preliminary screening of obstructive sleep apnea hypopnea syndrome

    Objective To discuss the screening and diagnostic value of nocturnal oximetry saturation monitoring combined with clinical score (CS) for patients with obstructive sleep apnea hypopnea syndrome (OSAHS). Methods A total of 106 snorers were recruited in the analysis whose general information and medical history were collected respectively. All patients received polysomnography (PSG) and oximeter monitoring. The patients were divided into a non-OSAHS group and an OSAHS group according to apnea hypopnea index (AHI). A correlation analysis was made between PSG-AHI and oximeter-ODI to analyze the diagnostic sensitivity and specificity of different ODI combined with CS for OSAHS. Results The AHI, ODI, CS for the non-OSAHS group were 1.8±1.4 times/h, 2.6±3.5 times/h and 1.0±0.8; while for the OSAHS group they were correspondingly 37.3±23.9 times/h, 31.0±24.1 times/h, 2.6±1.1. There was a significant correlation between ODI and AHI (r=0.943, P<0.01). The sensitivity and specificity of ODI≥5 times/h combined with CS≥2 for diagnosis of OSAHS were 91.7% and 94.1% respectively, which had the value of preliminary screening. The sensitivity and specificity of ODI≥10 times/h combined with CS≥2 for diagnosis of OSAHS were 77.8% and 100.0% respectively, which would not result in misdiagnose for severe patients with AHI >30 times/h, so it could be an index of severe OSAHS screening. Conclusion Nocturnal oxyhemoglobin saturation monitoring combined with clinical score is of significant value for initial diagnosis of OSAHS.

    Release date:2017-05-25 11:12 Export PDF Favorites Scan
  • Effectiveness of sacroiliac screw implantation assisted by three-dimensional printed faceted honeycomb guide plate in treatment of posterior pelvic ring fracture

    Objective To investigate the effectiveness of sacroiliac screw implantation assisted by three-dimensional (3D) printed faceted honeycomb guide plate in the treatment of posterior pelvic ring fracture. Methods The clinical data of 40 patients with posterior pelvic ring fractures treated with sacroiliac screw implantation between December 2019 and December 2022 were retrospectively analyzed. Among them, 18 cases were treated with sacroiliac screws fixation assisted by 3D printed faceted honeycomb guide plate (guide plate group), and 22 cases were treated with sacroiliac screws percutaneously fixation under fluoroscopy (conventional group). There was no significant difference in baseline data (P>0.05) such as gender, age, time from injury to operation, and Dennis classification between the two groups. The implantation time, frequency of C-arm X-ray fluoroscopy, frequency of guide pin adjustment of each sacroiliac screw, and postoperative complications and bone healing were recorded. Majeed score was used to evaluate the functional recovery at 6 months after operation, and CT was used to observe whether the screw penetrated the bone cortex. The deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point was measured on the sagittal CT images of the guide plate group. Results The number of screws implanted in S1 and S2 vertebral bodies was 14 and 16 respectively in the guide plate group, and 17 and 18 respectively in the conventional group. The implantation time of each sacroiliac screw, the frequency of C-arm X-ray fluoroscopy, and the frequency of guide pin adjustment in S1, S2, and all vertebrae in the guide plate group were significantly less than those in the conventional group (P<0.05). Patients in both groups were followed up 8-48 months, with an average of 19.7 months. There was no incision infection, screw displacement, or internal fixation loosening in both groups. Callus growth was observed in all patients at 12 weeks after operation, and bone healing was achieved in all patients. The healing time ranged from 12 to 24 weeks, with an average of 15.7 weeks. No sacroiliac screw penetrated the bone cortex in the guide plate group; 2 patients in the conventional group had sacroiliac screws penetrating the bone cortex without damaging blood vessels or nerves. In the guide plate group, the deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point were (2.91±1.01), (2.10±0.74), and (1.67±0.70) mm, respectively, with an average deviation of (2.19±1.22) mm. There was no significant difference in Majeed function evaluation between the two groups at 6 months after operation (P>0.05). Conclusion The application of 3D printed faceted honeycomb guide plate in sacroiliac screw implantation for posterior pelvic ring fracture can shorten the screw implantation time, reduce the frequency of fluoroscopy and guide pin adjustment, and reduce the risk of screw penetration through the bone cortex.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content