west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WANG Youhua" 2 results
  • Effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament tibial insertion fracture in adults

    Objective To explore the effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament (PCL) tibial insertion fractures in adults. Methods Between October 2019 and October 2021, 16 patients with PCL tibial insertion fractures were treated with arthroscopic binding fixation using suture through single bone tunnel. There were 11 males and 5 females with an average age of 41.1 years (range, 26-58 years). The fractures were caused by traffic accident in 12 cases and sports in 4 cases. The time from injury to operation ranged from 2 to 10 days with an average of 6.0 days. The fractures were classified as Meyers-McKeever type Ⅱ in 4 cases and type Ⅲ in 9 cases, and Zaricznyi type Ⅳ in 3 cases. There were 2 cases of grade Ⅰ, 7 cases of grade Ⅱ, and 7 cases of grade Ⅲ in the posterior drawer test. There were 3 cases combined with lateral collateral ligament injury and 2 cases with meniscus injury. The visual analogue scale (VAS) score, Lysholm score, International Knee Documentation Committee (IKDC) score, and knee range of motion were used to evaluate knee joint function. The posterior drawer test and knee stability tester (Kneelax 3) were used to evaluate knee joint stability. The X-ray films were used to evaluate fracture reduction and healing. Results All incisions healed by first intention after operation. There was no incision infection, popliteal neurovascular injury, or deep venous thrombosis of lower limbs. All patients were followed up 6-12 months, with an average of 10 months. X-ray films at 6 months after operation showed the fractures obtained bone union. There were 11 cases of grade 0, 4 cases of gradeⅠ, and 1 case of grade Ⅱin posterior drawer test, showing significant difference when compared with preoperative results (Z=23.167, P<0.001). The VAS score, Lysholm score, IKDC score, knee range of motion, and the results of Kneelax3 examination all significantly improved when compared with preoperative results (P<0.05). Conclusion For adult patients with PCL tibial insertion fractures, the arthroscopic binding fixation using suture through single bone tunnel has the advantages of minimal trauma, good fracture reduction, reliable fixation, and fewer complications. The patient’s knee joint function recovers well.

    Release date: Export PDF Favorites Scan
  • Effectiveness analysis of proximal humerus internal locking system plate combined with rotator cuff reinforcement suture in treatment of Neer type Ⅳ proximal humerus fracture

    Objective To investigate the effectiveness of proximal humerus internal locking system (PHILOS) plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture. MethodsThe clinical data of 48 patients with proximal humeral fractures admitted between January 2016 and December 2020 were retrospectively analyzed, including 18 males and 30 females. The age ranged from 28 to 69 years (mean, 56.3 years). The causes of injury included falling in 39 cases and traffic accident in 9 cases. The time from injury to operation was 2-5 days (mean, 2.8 days). All of them were Neer type Ⅳ proximal humerus fractures, including 11 patients with dislocation. All patients underwent internal fixation with a PHILOS plate after anatomical reduction of the greater nodule, and the rotator cuff was sutured to the plate to reinforce fixation. The operation time was recorded, the wound healing, fracture healing, and complications were observed. The visual analogue scale (VAS) score, Constant-Murley shoulder score, University of California Los Angeles (UCLA) score, and American Shoulder and Elbow Surgeons (ASES) score were used to evaluate shoulder function before operation, at 3 months after operation, and at last follow-up. Results The operation time ranged from 65 to 90 minutes (mean, 76.9 minutes). All incisions healed by first intention. All patients were followed up 9-16 months (mean, 12 months). Fracture reduction was good and all fractures healed, the healing time was 2-6 months (mean, 4.6 months). There was no complication such as subacromial impingement, fracture redisplacement, and screw removal during follow-up. One patient had humeral head necrosis, but the basic function of the shoulder joint was acceptable, the symptoms were mild, and no treatment was performed. At 3 months after operation, the upper limb function of the patients basically recovered. The VAS score, Constant-Murley score, UCLA score, and ASES score significantly improved at 3 months after operation and at last follow-up when compared with preoperative, and further improved at last follow-up than at 3 months after operation (P<0.05). ConclusionPHILOS plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture has the advantages of promoting early postoperative rehabilitation exercise, improving postoperative function of shoulder joint, and reducing complications.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content