west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WEI Wei." 3 results
  • Echocardiography in Evaluation of Right Ventricular Function

    Abstract: Right ventricular dysfunction or right heart failure is a complex clinical syndrome and often leads to a poor prognosis and high mortality. In order to detect right ventricular dysfunction at an early stage, provide a therapy guidance and evaluate treatment outcomes, right ventricular function evaluation has aroused more and more concern in clinical physicians. With the advantages of being non-invasive, accuracy and repetitiveness, echocardiography is used extensively in the assessment of heart function. In this review, we focus on how to use echocardiography to evaluate right ventricular function easily, efficiently, accurately and sensitively, and provide a good foundation for its further clinical application.

    Release date:2016-08-30 05:51 Export PDF Favorites Scan
  • Tissue Doppler Strain Rate Imaging to Evaluate the Impact of Dopamine and Milrinone on Left Ventricular Function of Patients Undergoing Heart Valve Replacement

    Abstract: Objective To use tissue Doppler strain rate imaging to evaluate the impact of low dose dopamine and milrinone on systolic and diastolic function of the left ventricle of patients undergoing heart valve replacement. Methods  Forty patients undergoing selective heart valve replacement in West China Hospital of Sichuan University between March and May 2011 were included in this study. All the patients were randomized into 2 groups with 20 patients in each group: milrione group and dopamine group. After anesthesia induction and before cardiopulmonary bypass setup, left ventricular ejection fraction (LVEF) was measured by echocardiography. Tissue Doppler strain rate imaging was used to measure the left ventricular lateral wall and midventricular segment from the four-chamber view, which was compared with Doppler parameters. Results LVEF, ratio of early-diastolic to end-diastolic velocity (E/A) of transmitral flow, ratio of mitral  inflow velocity to early diastolic velocity in the annulus (E/Et) of both 2 groups were significantly different between before and after dopamine and milrinone administration (P<0. 05). In the milrinone group, 4 segments systolic peak velocity (Vs), 1 segment early diastolic peak velocity (Ve), 4 segments late diastolic peak velocity (Va), 3 segments Ve/Va ratio, 2 segments systolic peak strain rate (SRs), 2 segments late diastolic peak strain rate (SRa), and 3 segments early diastolic peak strain rate SRe/SRa ratio after dopamine and milrinone administration were significantly higher than those before dopamine  and milrinone administration (P<0. 05). In the dopamine group, 4 segments systolic peak velocity (Vs), 1 segment Ve, 4 segments Va, 1 segment Ve/Va ratio, 2 segments SRs, 1 segment SRe, 1 segment SRa, and 1 segment SRe/SRa ratio after dopamine and milrinone administration were significantly higher than those before dopamine and milrinone administration (P<0.05). To compare the milrione group and dopamine group after medication administration, 2 segments Vs, 4 segments Va, 1 segment SRe, 1 segment SRa, 2 segments Ve/Va ratio, and 2 segments SRe/SRa ratio of the milrione group were significantly higher than those of the dopamine group (P<0.05), and 1 segment Vs, two segments SRs of the milrione group were significantly lower than those of the dopamine group (P<0.05). Conclusion Both milrinone and dopamine can improve left ventricular systolic function of perioperative patients undergoing heart valve replacement assessed by tissue Doppler strain rate imaging, while milrinone can improve the diastolic function of the left ventricle on the long axis more significantly.

    Release date:2016-08-30 05:28 Export PDF Favorites Scan
  • The Impact of Mechanical Ventilation on Pulse Oximetry in Thoracic Cavity

    摘要:目的: 评价机械通气对胸腔内脉搏氧饱和度的影响。 方法 :以食道、气管和降主动脉作为胸腔内脉搏氧饱和度的监测位点,将改制后的氧饱和度探头分别固定于上述部位,并连接于同一监护仪上。纯氧通气,待上述氧饱和度容积波波形和读数稳定,停止机械通气30s。以录像的方式记录机械通气停止前后30 s内食道、气管和降主动脉SpO2容积波和读数的变化。同时记录舌SpO2。 结果 :机械通气时,食道、气管和降主动脉三个监测位点均可获得异常高大的SpO2容积波;停止通气时,异常高大的氧饱和度波形消失。食道、气管和降主动脉脉搏容积波变异率分别为112%,74%,302%。降主动脉脉搏容积波的变异率明显高于食道和气管( 〖WTBX〗P <005)。机械通气停止前后30s内食道、气管和降主动脉的SpO2读数变化无显著差异(〖WTBX〗P >005)。 结论 :机械通气对胸腔内食道、气管和降主动脉氧饱和度读数无影响,主要影响是脉搏容积波。且各位点间脉搏氧容积波受呼吸的影响不同。Abstract: Objective: To investigate the impact of mechanical ventilation on pulse oximetry in thoracic cavity. Methods : After dogs anesthesia induction and thoracotomy, pulse oximeters were simultaneously placed at esophagus, trachea, and descending aorta, and connected with the same monitor for SpO2 monitoring. During ventilation with 100% oxygen, the mechanical ventilator was temporarily switched off for 30 seconds after high quality PPG waveforms and SpO2 readings were obtained. SpO2 signals and readings from esophagus (SeO2), trachea (StraO2), descending aorta (SDAO2) shown on the monitoring screen were recorded by the SONY video before and after stopventilation. And StonO2 were also recorded. Results : Abnormally largeamplitude PPG waves were found in normal waves at monitoring sites of esophagus, trachea, and descending aorta in all animals during ventilation; however, they disappeared without ventilator. The variation rate in ventilationinduced PPG amplitude were 112%, 74%, 302% at esophagus, trachea and descending aorta respectively. The PPG amplitude variation rate from SDAO2 was higher than that from SeO2 and StraO2 (〖WTBX〗P <005). However, the SpO2 readings obtained from pulse oximetries in all sites were no significantly statistical difference within 30s before and after temporarily stopventilation (〖WTBX〗P >005). Conclusion : Abnormally amplitude PPG waveforms from oximetry probe placed at esophagus, trachea, and descending aorta were induced by ventilation. The Variation rate in ventilationinduced PPG amplitude was various at different monitoring sites. The SpO2 readings from esophagus, trachea, and descending aorta were not significantly contaminated by ventilation.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content