ObjectiveTo summarize the research progress of relationship between distal landing zone geometric and outcomes of endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm. MethodsThe domestic and foreign literature on the accumulation of the impact of proximal and distal landing zone geometric morphology on clinical outcomes, the evaluation methods for related complications of proximal and distal landing zones, preventive measures for adverse outcomes related to the geometric morphology of the distal landing zone, and the pathophysiological mechanisms of complications related to the distal landing zone were retrieved to make an review. ResultsThe irregular geometric morphology of the proximal landing zone was closely associated with adverse events following EVAR. The morphology of the distal landing zone was actually more complex than that of the proximal zone, and the measurement methods for its parameters were also more complicated. Common methods used in the literature for studying landing zones included the centerline distance method, the minimum distance method, and the landing area method. Primary preventive measures for adverse outcomes related to the geometry of the distal landing zone included increasing radial support force and contact area, using endostaples, and extending the landing zone. In addition to anatomical factors, the distal landing zone was also influenced by various pathophysiological factors. ConclusionsThe morphology and related pathological changes of the distal landing zone significantly impact the clinical outcomes following EVAR for abdominal aortic aneurysm. However, current research on the distal landing zone is limited. Future studies should focus on developing new technologies and methods to improve the evaluation and management of the distal landing zone, thereby reducing the complications after EVAR, enhancing the success rate of the surgery, and improving patient survival quality.
ObjectiveTo analyze the main points and advantages of covered endovascular reconstruction of aortic bifurcation (CERAB) technique in the treatment of complex aortic and iliac artery lesions. MethodThe data of the patient with bilateral common iliac artery stenosis and lower abdominal aortic calcification treated by CERAB technology in the Department of Vascular Surgery of West China Hospital of Sichuan University and the technology in combination with the characteristics of balloon-expandable covered stent were analyzed. ResultsThe lesions were successfully treated by CERAB technique. The stents of bilateral iliac arteries were in perfect shape and good adherence. The radiography of the abdominal aorta and bilateral internal and external iliac arteries were well displayed. ConclusionsFrom analysis results of this case, CERAB technology is effective and feasible in treatment of lesions at the bifurcation of the main aortic and iliac artery. The shape of aortic bifurcation is satisfactorily recovered. The key point for the successful implementation of this technology is balloon-expandable covered stent.
Objective To investigate the technical feasibility and effectiveness of intraoperative sac embolizaion with coils and fibrin glue for preventing type Ⅱ endoleak after endovascular aneurysm repair (EVAR). Methods A patient with abdominal aortic aneurysm (AAA), which had high risk of type Ⅱ endoleaks, was treated with combined packing of coils and fibrin glue in order to prevent type Ⅱ endoleak after EVAR. Percutaneous catheter preset and balloon occlusion were used to ensure accurate packing. Results At the end of the operation, the angiography showed that the blood flow of the stent and distal artery was unobstructed, there was no type Ⅰ and Ⅲ endoleaks, and delayed angiogram showed no collateral circulation of aneurysm. The procedure was successful. The operative duration was 120 min and the blood loss was only 20 mL. No complications such as colonic ischemia and ectopic embolism occurred, and the patient was discharged on 3 days after operation. At 6 months after follow-up, the computerized topographic angiography showed that the aneurysm cavity was completely thrombotic, without type II endoleak, and the diameter and volume of aneurysm were reduced. Conclusions The technique of intraoperative sac embolizaion with coils and fibrin glue during EVAR is safe and effective to prevent postoperative endoleaks, which is simple and feasibility. Intraoperative indwelling catheter and balloon blocking are the key points of successful implementation of this technique.
ObjectiveReporting a case of hybrid procedure of extensive thoracoabdominal aortic aneurysm (TAAA) with type B dissection due to Marfan syndrome (MFS) using a prosthetic graft as the distal landing zone for stent-graft.MethodsRetrospectively summarize in-hospital profiles of a patient for who was diagnosed as MFS complicated with TAAA and type B dissection and admmited to Vascular Surgery Department of West China Hospital in May 2018. A GORE-TEX 18 mm×9 mm Y-shaped graft was sewn side-to-end to the bifurcation of left common iliac artery as the inflow site, and a self-made penta-limb graft was sewn side-to-end to the bifurcation of the 18 mm graft. The visceral and bilateral iliac arteries were reconstructed subsequently. Then, the release of the stent-graft was designed from distal to proximal. The distal part of the stent-graft was anchored into the main body of the 18 mm Y-shaped graft.ResultsThe patient underwent the operation successfully with a duaration of 6 h, blood loss of about 800 mL. No serious postoperative complications occurred. Computed tomography angiography at 2-year follow-up showed that the bypass grafts were patent without endoleak, stent migration, stent infolding or infections of the vessel graft and endograft.ConclusionThis modified management of the landing zone could be a proper choice for this kind of rare case as extensive aneurysm or dissection involved in patients with MFS.