west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WUWen-jie" 2 results
  • Study on Early Effects of Vectra-T Dynamic Plate for Cervical Spondylosis

    ObjectiveTo study the efficacy of anterior cervical Vectra-t dynamic plate and titanium mesh for cervical spondylosis. MethodsA retrospectively analysis involving 20 cases (44 sections) from June 2010 to October 2012 was performed in the department of orthopaedic in the West China Hospital of Sichuan University. All patients received the operation of anterior cervical vertebral resection decompression, titanium mesh and bone graft, and Vectra-T plate. The data of the JOA scores, cervical curvature, the conditions of vertebral body fusion after bone graft and the situation of titanium mesh subsidence were all collected. Statistical analysis were performed using SPSS 19.0 software. Resultsa) All the 20 cases received a 12-to 30-month follow-up. The results of statistical analysis showed that:the JOA scores were as follows:7.68±1.66 for preoperative, 10.91±1.97 for after surgery and 12.74±1.27 for the endpoint of follow-up, and significant differences were found between these scores (P < 0.05). b) There was no loose of screw or plate. The local cervical angle and regional cervical angle were improved after surgery. In the 44 segments of fusion, 43 segments fused within 6 months, one of the segment delayed to fuse 12 months after surgery. c) The subsidence of titanium mesh were 2.7±2.7 mm on average in 3 months after surgery, 3.6±1.0 mm on average in 6 months after surgery, 3.9±1.2 mm on average in 12 months after surgery and 4.0±1.2 mm on average in last follow-up. Titanium mesh subsidence mainly concentrated in the postoperative period of 6 months. After six months of titanium mesh subsidence was no longer apparent. ConclusionThe application of Vectra-T dynamic plate can effectively improve the curvature of the cerical sagittal position, prevent protrusion deformity, reduce the related complications after bone graft, effectively avoid the stress shelter in the static plate, andspromote the fusion between the cervical vertebral bodies. However, the long-term curative effects are still needed to be assessed by large sample randomized controlled trials with long-term follow-up.

    Release date: Export PDF Favorites Scan
  • An Applied Anatomy Research of Digital-CT-based Unilateral Open-door Cervical Expansive Laminoplasty of C7

    ObjectiveTo explore early clinical effects of Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium minitype plate fixation, to research the data of the best slotting in the CT-based open-door cervical operation and to provide the reference for accurate operation. MethodsA retrospective analysis of the patients who had received Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium plate fixation from West China Hospital of Sichuan University from February 2013 to November 2013 were performed. The neurological function assessment results (JOA score), cervical curvature indexhave, Pavlov value, spinal canal cross-sectional area and different position, angle and depth of C7 lamina slotting data of all patients before and after the operation were all analyzed and compared. ResultsA total of 58 patients were included. The postoperative JOA score was significantly higher than that of the preoperative (9.4±2.9 vs. 14.7±2.6, t=11.417, P=0.000). The sagittal diameter of vertebral canal (21.3±2.1 mm vs. 9.7±2.1 mm, t=27.737, P=0.000), Pavlov value (0.92±0.13 vs. 0.44±0.12, t=30.621, P=0.000), and spinal canal cross-sectional area (276±37 mm2 vs. 129±25 mm2, t=32.104, P=0.000) at the end of the last follow-up were significantly greater than those of preoperative. When comparing the last follow-up with preoperative, cervical curvature index showed significant difference (11.2±11.5 vs. 9.3±11.7, t=-1.713, P=0.000). Significant differences were found in the comparison of the ideal position and angle of the open door of the C7 lamina and the angle and position of the operation (all P values >0.05); when comparing the position and angle of the ideal position and angle of the C7 lamina hinge with that of the actual operation, no significant differences were found (all P values >0.05); but when comparing the ideal depth with the actual depth of the operation, a significant difference was found (P<0.05). ConclusionCenterpiece micro plate used in posterior cervical expansive open-door laminoplasty forming operation of laminectomy fixed screw loosening and plate breakage, can effectively maintain the lamina in the open state, and prevent it to be closed. The patients have good recovery of nerve function after operation and the clinical efficacy is good.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content